<Spec id="128" path="\2\d\2dfbfe5bf1f8e79ca0e0173b4b67af68.pdf"><Text id="2993" page="1">The measurement units to be used shall be the International System (SI), or the Anglo-saxon system of units, to be stablished at the beginning of the Project.</Text><Text id="2994" page="1">For other terms and abbreviations included in this specification, the definitions to consider shall be the ones established in the reference IEC standard 60034.</Text><Text id="2997" page="1">The motor shall be suitable for continuous operation to nominal power respecting the limits of temperature indicated in IEC standard 60034 located outdoors, without protection and in the following conditions:</Text><Text id="3003" page="1">Chemically aggressive atmosphere, salty, dusty and corrosive, common to industrial facilities.</Text><Text id="3004" page="1">More restrictive conditions will be detailed in the BDD document and/or in the particular documentation of the project (data sheets, particular requisition, etc.)</Text><Text id="3006" page="1">Unless indicated otherwise in the project documents, the motors will be suitable for continuous running at rated output (at ambient temperature and at the voltage and frequency values defined in the project documents) with variations of voltage and frequency within the limits of “zone A” (defined in the standard IEC 60034-1), without exceeding the temperature rise defined for the insulation systems of thermal class B (80K).</Text><Text id="3007" page="1">Furthermore, the motors will be suitable for continuous running at rated output (at ambient temperature and at the voltage and frequency values defined in the project documents) with voltage and frequency variations exceeding the limits of ”zone A”, within zone B, but without exceeding the temperature rise permitted by the insulation system of thermal class B by more than 10K.</Text><Text id="3009" page="1">Unless otherwise specified in the project documentation, motors shall comply with the following requirements:</Text><Text id="3010" page="1">a) The motors shall be prepared on-line starting.</Text><Text id="3011" page="1">Based on the characteristics of the equipment being operated, the motor manufacturer shall specify any limitations and recommend the most appropriate motor for each specific case.</Text><Text id="3012" page="1">2 DEFINITIONS © REPSOL S. A. Madrid, last update 2004-2017</Text><Text id="3013" page="1">Document Code: Design Specification: HIGH VOLTAGE ELECTRIC INDUCTION ED-P-02.01-04 MOTORS (IEC 60034) Technical Department Engineer Division Page 5 of 27 ELECTRICITY SEPTEMBER 2017</Text></Spec>