<?xml version="1.0" encoding="utf-8"?>
<Spec id="425" path="\5\d\5d47789046211014095883e61003dc47.pdf"><Text id="16256" page="3">The system is a submersible motor pump intended for drainage and grey water applications, operating under submerged conditions in stationary or transportable installations.</Text><Text id="16257" page="3">The system shall pump grey water and drainage water from submerged environments and shall transport fluids containing solid particles up to 12 mm in diameter.</Text><Text id="16258" page="3"> The system shall deliver a maximum flow rate of at least 130 m³/h. [A: SYS-SMP-004]</Text><Text id="16259" page="3">The system shall achieve a maximum head of at least 26 m and operate at immersion depths up to 7 m (standard version).</Text><Text id="16261" page="4">The system shall be designed as a close-coupled, single-stage pump and shall incorporate a vertical discharge outlet.</Text><Text id="16262" page="4">The motor shall comply with EN 60043 T1. The insulation of motors must be class B and degree of protection shall be IP68.</Text><Text id="16263" page="4">The system shall operate continuously at fluid temperatures up to 50°C.</Text><Text id="16264" page="4">The system shall operate continuously at fluid temperatures up to 40°C for wearresistant variants (B/BH).</Text><Text id="16265" page="4">The system shall withstand fluid temperatures up to 90°C for a duration not exceeding 3 minutes. The system shall operate at immersion depths up to 10 m (variant B/BH).</Text><Text id="16267" page="4">The system shall use an open multi-vane impeller. The system shall include a double mechanical sealing system consisting of:</Text><Text id="16270" page="4">• an intermediate lubricant chamber [I: SYS-SMP-07] Maintenance-free rolling element bearings are incorporated in the system design.</Text><Text id="16271" page="4">The system shall include an electric motor suitable for submersible operation. The motor shall support direct-on-line and star-delta starting methods. The motor shall comply with IEC 60038 voltage standards.</Text><Text id="16273" page="5">The motor shall have insulation class B and protection class IP68 and include integrated thermal protection switches.</Text><Text id="16275" page="5">The system shall be constructed from corrosion-resistant materials suitable for grey water. The system shall include coated hydraulic components for corrosion protection.</Text><Text id="16277" page="5">The system shall support operation in abrasive fluids when configured as variant B/BH.</Text><Text id="16279" page="5">The system shall provide a discharge connection suitable for vertical piping integration and electrical interfaces compatible with standard industrial power systems.</Text><Text id="16281" page="5">The Supplier shall ensure that the submersible motor pump and all associated components comply with all applicable local, national, and international laws, regulations, and standards in force at the time of delivery.</Text><Text id="16283" page="5">The equipment shall meet all relevant directives related to electrical safety, environmental protection, and mechanical integrity (e.g., CE marking where applicable).</Text><Text id="16284" page="6"> Compliance with relevant standards such as DIN, ISO, and IEC is mandatory.</Text><Text id="16285" page="6"> The Contractor shall provide a minimum warranty of:</Text><Text id="16287" page="6">• 30 months from delivery (whichever occurs first)</Text><Text id="16289" page="6">• All defects shall be corrected at no cost</Text><Text id="16290" page="6">• Response time for critical failures shall not exceed 48 hours Spare parts availability shall be guaranteed for a minimum of 10 years.</Text><Text id="16291" page="6"> The Contractor shall comply with all occupational safety regulations.</Text><Text id="16292" page="6">The equipment must ensure safe operation under submerged conditions. Hazardous substances shall be avoided or declared in accordance with EU regulations.</Text><Text id="16293" page="7">The contracting authority is seeking to modernize its IT infrastructure to improve service delivery. This procurement forms part of a wider sustainability programmed across public services.</Text><Text id="16294" page="8">Figure 2: Submersible Motor Pumping Station PID Diagram</Text><Text id="16296" page="8">The contract covers the supply, installation, and maintenance of 250 desktop computers.</Text><Text id="16297" page="8">Services are required across all regional offices within the stated geography.</Text><Text id="16298" page="1">0 24.04.2026 Issue for Quotation APP’D 1 17.04.2026 Issue for Quotation APP’D 2 10.04.2026 Issue for Quotation APP’D</Text><Text id="16299" page="6">ID Parameter Requirement / Specification [A: SYS-SMP-18] Pump Type Submersible centrifugal pump [A: SYS-SMP-19] Rated Flow (Q) 50 m³/h [A: SYS-SMP-20] Motor Type Submersible, squirrel cage induction motor</Text><Text id="16300" page="7">ID Parameter Requirement / Specification [A: SYS-SMP-21] Power Supply 400 V ±10%, 50 Hz, 3-phase [A: SYS-SMP-22] Protection Class Minimum IP68 [A: SYS-SMP-23] Insulation Class Class F or higher [A: SYS-SMP-24] Cooling Method Liquid-cooled (surrounding medium or jacket) [A: SYS-SMP-25] Max. Liquid Temperature Minimum 40°C [A: SYS-SMP-26] Shaft Material Stainless steel [A: SYS-SMP-27] Bearings Heavy-duty, grease lubricated [A: SYS-SMP-28] Cable Type Submersible, watertight [A: SYS-SMP-29] Dry Run Protection Required (thermal or sensor-based) [A: SYS-SMP-30] Noise Level ≤ 50 dB(A) [A: SYS-SMP-31] Coating Corrosion-resistant epoxy coating [A: SYS-SMP-32] Compatible with PLC/SCADA Control System Compatibility [A: SYS-SMP-33] Standards Compliance DIN / ISO / IEC applicable standards [A: SYS-SMP-34] Testing Factory Acceptance Test (FAT) required [A: SYS-SMP-35] Documentation Manuals, drawings, certificates</Text></Spec>