<?xml version="1.0" encoding="utf-8"?>
<Spec id="443" path="\9\2\92b572b1e100d601988355c4e603f5f7.pdf"><Text id="18592" page="30">In addition to the requirements above, fibre-optic cables intended for direct burial shall have a secondary lead sheath, or equivalent multi-layer sheath.</Text><Text id="18593" page="30">The lead sheath or multilayer sheath shall provide a barrier against moisture, chemicals, water, solvents, environment and hydrocarbon oil attacks.</Text><Text id="18594" page="30">All onshore underground buried cables shall be provided with Lead Sheath as a moisture and chemical barrier in accordance with BS EN 50288 and shall comply to EEMUA 133 for lead quality. Alternatively, Aluminum/high density polyethylene/polyamide (AL/HDPE/PA) multi-layer inner sheath can be acceptable subject to COMPANY prior approval. VENDOR shall provide ‘Type Test’ certificates, from a test house acceptable to COMPANY, for AL/HDPE/PA multi-layer inner sheath cables to validate degree of ingress protection against water, organic and non-organic chemicals.</Text><Text id="18595" page="30">11.2.2 Bedding Layer The bedding layer shall be provided between lead sheath and armour for underground cables. The material of construction for the bedding layer shall be same as that of the inner sheath material. 11.2.3 Steel Wire Armour Armored cable shall have Galvanized Steel Wire Armour under outer sheath. The galvanized steel wire armour shall comply to requirements of EN 10257-1 and, EN 10218-1. The coating of steel wire shall comply with the requirements of EN 10244-2. 11.2.4 Outer Sheath</Text><Text id="18596" page="30">Outer sheath material shall be minimum PVC or better and comply with this specification requirements. Outer sheath shall be Low Smoke Zero Halogen Flame Retardant Compound. Outer sheath shall be</Text><Text id="18597" page="1">THE CONTENTS OF THIS DOCUMENT ARE PROPRIETARY AND CONFIDENTIAL.</Text><Text id="18602" page="1">Abdulmunim Saif Al Kindy NAME: Abdulmunim Al Kindy TITLE: Executive Director PT&amp;CS EFFECTIVE DATE:</Text><Text id="18609" page="2">1 June 2020 1 Asadullah Malik / Sr. Engineer, I&amp;C, TE.</Text><Text id="18612" page="2">ENDORSED BY (Designation / Initial) Abdulla Al Shaiba/ VP-GPE</Text><Text id="18613" page="2">ENDORSED BY (Designation / Initial) Zaher Salem/ SVP-GPE</Text><Text id="18615" page="130">4. Cable screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="18616" page="130">5. Inner jacket Flame retardant Low Smoke Zero Halogen Compound ,LSZH. Colour: Black.</Text><Text id="18617" page="130">6. Inner Sheath Lead Sheath (or Lead pipe). A multi-layered Inner Sheath (AL/HDPE/PA instead of lead sheath) will be considered if the multi-layer sheath provides the same protection as a lead sheath for hydrocarbons, chemical and solvents, saline water ingress and vermin protection, as per BS 50288-7 section 4.18.2.</Text><Text id="18618" page="130">7. Bedding Flame retardant Low Smoke Zero Halogen Compound ,LSZH. Colour: Black.</Text><Text id="18620" page="130">9. Outer jacket Flame retardant Low Smoke Zero Halogen Compound. Entire cable assembly shall be Flame retardant to IEC 60332.Pt.3.Cat`A’</Text><Text id="18621" page="131">(G6) Two core, Collective Screen, armoured, flame retardant (Control Cable). (XLPE/Coll Scr/SWA/ LSHF) Voltage Rating: 300/500V</Text><Text id="18624" page="2">Group Projects &amp; Engineering is the owner of this Specification and responsible for its custody, maintenance and periodic update.</Text><Text id="18625" page="2">In addition, Group Projects &amp; Engineering is responsible for communication and distribution of any changes to this Specification and its version control.</Text><Text id="18626" page="2">This specification will be reviewed and updated in case of any changes affecting the activities described in this document.</Text><Text id="18628" page="3">a) The following are inter-relationships for implementation of this Specification:</Text><Text id="18629" page="3">i. ADNOC Upstream and ADNOC Downstream Directorates and</Text><Text id="18630" page="3">ii. ADNOC Onshore, ADNOC Offshore, ADNOC Sour Gas, ADNOG Gas Processing. ADNOC LNG, ADNOC Refining, ADNOC Fertilisers, Borouge, Al Dhafra Petroleum, Al Yasat</Text><Text id="18631" page="3">b) The following are stakeholders for the purpose of this Specification: ADNOC PT&amp;CS Directorate.</Text><Text id="18632" page="3">c) This Specification has been approved by the ADNOC PT&amp;CS is to be implemented by each ADNOC Group company included above subject to and in accordance with their Delegation of Authority and other governance-related processes in order to ensure compliance</Text><Text id="18633" page="3">d) Each ADNOC Group company must establish/nominate a Technical Authority responsible for compliance with this Specification.</Text><Text id="18634" page="3">DEFINED TERMS / ABBREVIATIONS / REFERENCES “ADNOC” means Abu Dhabi National Oil Company.</Text><Text id="18635" page="3">“ADNOC Group” means ADNOC together with each company in which ADNOC, directly or indirectly, controls fifty percent (50%) or more of the share capital.</Text><Text id="18636" page="3">“Approving Authority” means the decision-making body or employee with the required authority to approve Policies &amp; Procedures or any changes to it.</Text><Text id="18637" page="3">“Business Line Directorates” or “BLD” means a directorate of ADNOC which is responsible for one or more Group Companies reporting to, or operating within the same line of business as, such directorate.</Text><Text id="18638" page="3">“Business Support Directorates and Functions” or “Non- BLD” means all the ADNOC functions and the remaining directorates, which are not ADNOC Business Line Directorates.</Text><Text id="18639" page="3">“CEO” means chief executive officer. “Group Company” means any company within the ADNOC Group other than ADNOC. “Specification” means this Instrument and Control Cables Specification.</Text><Text id="18640" page="3">The intranet copy of this document located in the section under Group Policies on One ADNOC is the only controlled document. Copies or extracts of this document, which have been downloaded from the intranet, are uncontrolled copies and cannot be guaranteed to be the latest version.</Text><Text id="18643" page="6">The purpose of this specification is to define the minimum mandatory technical requirements for design, procurement, manufacturing, installation, testing and packing of Instrument and Control cables.</Text><Text id="18644" page="6">2 SCOPE 2.1 The scope of this specification is limited to following types of Instrumentation and Control Cables:</Text><Text id="18646" page="6">4. Communication cables (such as RS-232, RS485, Ethernet etc.)</Text><Text id="18648" page="6">2.2 This specification excludes following types of cables:</Text><Text id="18651" page="6">3. 230V AC Power Cables for powering Instruments and Control Equipment</Text><Text id="18653" page="6">6. Proprietary Control System’s cables supplied by ICSS and Mechanical Package Vendors.</Text><Text id="18654" page="6">2.3 For project specific additional requirements, refer to instrumentation cable requirements stated in respective project’s Purchase Requisition documentation.</Text><Text id="18657" page="9">ADNOC Group Companies Instrument and Control Cable requirements documents part of Cable Purchase Order shall be referred for design and supply of equipment.</Text><Text id="18659" page="10">The following codes and standards, to the extent specified herein, form a part of this specification. When an edition date is not indicated for a code or standard, the latest edition in force at the time of order placement shall apply.</Text><Text id="18661" page="15">This specification shall be read in conjunction with respective project specific Cable Purchase Order and its referenced documents and Cable Data Sheets which fully defines project specific requirements.</Text><Text id="18662" page="15">The Codes and Standards referred to in this specification shall, unless stated otherwise, be the latest approved issue at the time of Purchase Order placement.</Text><Text id="18663" page="15">It shall be the VENDOR&apos;S and CONTRACTORS’S responsibility to be, or to become, knowledgeable of the requirements of the referenced Codes and Standards.</Text><Text id="18664" page="15">The VENDOR/CONTRACTOR shall notify the COMPANY of any apparent conflict between this specification, the related data sheets, the Codes and Standards and any other specifications noted herein.</Text><Text id="18665" page="15">Resolution and/or interpretation precedence shall be obtained from the COMPANY in writing before proceeding with the design/manufacture.</Text><Text id="18666" page="15">In case of conflict, the order of document precedence shall be:</Text><Text id="18671" page="15">Deviations from this specification are only acceptable where the VENDOR has listed in his quotation the requirements he cannot, or does not wish to comply with, and the COMPANY/CONTRACTOR has accepted in writing the deviations before the order is placed.</Text><Text id="18672" page="15">In the absence of a list of deviations, it will be assumed that the VENDOR complies fully with this specification.</Text><Text id="18673" page="15">Any technical deviations to the Purchase Order and its attachments including, but not limited to, the Data Sheets and Narrative Specifications shall be sought by the VENDOR only through Concession Request Format. Concession requests require CONTRACTOR’S and COMPANY’S review/approval, prior to the proposed technical changes being implemented. Technical changes implemented prior to COMPANY approval are subject to rejection.</Text><Text id="18674" page="17">9 DESIGN CONSIDERATIONS / MINIMUM DESIGN REQUIREMENTS Operation &amp; Design Life</Text><Text id="18675" page="17">All Instrument and Control cables shall be suitable for continuous operation of 30 years under the environmental conditions at ADNOC facilities.</Text><Text id="18676" page="17">Refer to Engineering Design Basis of ADNOC Group Company for respective Onshore or Offshore project environmental conditions. conditions. All cables shall be suitably designed for permanent operation under the prevailing environmental conditions specified in purchase order data sheets.</Text><Text id="18677" page="17">In general, the environment for outdoor installations shall be considered as high temperatures, high humidity, salty, sulphurous, dusty and corrosive. Cables shall be suitable for installation and operation over the full range of ambient temperature and humidity specified in the data sheets and in an environment containing trace amount of H2S, CO2 (sour &amp; corrosive atmosphere) and HC gases.</Text><Text id="18678" page="17">Cables exposed to direct sunlight (outdoor above ground) shall be manufactured using the best suitable UV stabilizers which enables the long life without stress cracking suited to Middle East Environment Conditions. Cables resistance to UV shall meet requirements of UL 1581 art. 1200.</Text><Text id="18679" page="17">All indoor systems shall continue to operate in HVAC upset conditions during which the temperature can fall to 0ºC or rise to 60ºC, and the humidity can vary between 5% and 95% non-condensing.</Text><Text id="18680" page="17">All cables installed indoors shall have Low Smoke Zero Halogen (LSZH) sheath material.</Text><Text id="18681" page="17">Unless otherwise specified, outdoor areas inside process plants shall be considered as hazardous. All cables laid outdoor shall be suitable for hazardous area specified in cable data sheet and shall comply with IEC 60079-11 &amp; 25 requirements.</Text><Text id="18682" page="17">Engineering Units Reference shall be made to Project Engineering Design basis for Units of Measurements.</Text><Text id="18684" page="18">The Instrument and Control cables shall be suitable for process facilities situated at onshore desert and offshore marine locations, operating at high ambient temperatures and H2S/CO2 sour gas corrosive environments.</Text><Text id="18685" page="18">Cables shall be suitable to install for following laying arrangements: (a) Outdoor directly buried in the ground (b) Outdoor concrete trenches with soil backfill (c) Outdoor on cable trays in the open air exposed to direct sunlight (d) Inside building in cable trays, conduits and ducts All cables shall be heat, oil, soil &amp; UV resistant; non-hygroscopic and gas &amp; vapor tight.</Text><Text id="18686" page="18">All cables shall be Flame Retardant and comply with IEC 60332-1-1&amp;2 and IEC 60332-3-22, Category A as a minimum.</Text><Text id="18687" page="18">All cables used for ESD, FGS and safety functions shall be Fire Resistant and comply with IEC 60331-21 .</Text><Text id="18688" page="18">Onshore and Offshore, Instrument and Control Cables shall be rated for 300/500V i.e. 300 V r.m.s. core to earth and 500 V r.m.s. core to core.</Text><Text id="18689" page="18">Temperature rating of all cables shall be 90°C under normal operating conditions. For temperature above 90°C, cables shall be customised based on application and intended high temperature requirements.</Text><Text id="18690" page="18">The Thermocouple extension and compensating cables design shall comply to IEC 60584-3. The Foundation Fieldbus cables design shall be comply to IEC 61158-2 Type A cables.</Text><Text id="18691" page="18">All outdoor cables buried in ground, laid in trenches or above ground in cable trays shall be armoured. All cables installed in the plant field areas and all cable runs from the plant areas to the cabinets located inside Instrument Equipment Room shall be considered as outdoor cables.</Text><Text id="18692" page="18">Indoor cables which are laid within the building between marshalling, system and other panels, should be unarmoured, shall have Low Smoke Zero Halogen (LSZH) sheaths and shall be suitable for installation within cable containment systems like cable trays or ducts. Unarmoured cables shall not be used for outdoor above ground or underground installations.</Text><Text id="18693" page="18">Mud resistant cables shall be considered for the entire wellhead platform at Offshore and Well pad area.</Text><Text id="18694" page="19">Cable Types and Selection Criteria Following types of cables shall be provided based on service and installation requirements:</Text><Text id="18695" page="19">(1) Flame Retardant Cables and Fire Resistant Cables</Text><Text id="18699" page="19">(5) Signal Cables (for 4-20 mA, Digital, Frequency, RTD, T/C, FF etc signals)</Text><Text id="18700" page="19">(6) Control Cables (for solenoid valves, beacons, hooter etc)</Text><Text id="18702" page="19">(8) Fibre Optic Cables To standardise cable construction, following number cores, pairs, triads and quads shall be used:</Text><Text id="18703" page="19">(1) Pair cables: 1P, 2P, 10P and 20P.</Text><Text id="18704" page="19">(2) Triad cables: 1T, 2T, 10T and 20T</Text><Text id="18706" page="19">(4) Multi-core cables: 2, 3, 4, 7, 11, 19, 27 and 37 The selection of cable type and minimum conductor size for various signal types shall be as follows:</Text><Text id="18707" page="20">Note 1: The conductor sizes mentioned above are the minimum requirements. CONTRACTOR shall verify conductor sizes based on cable length, voltage drop and power consumption requirements of instruments.</Text><Text id="18708" page="20">Note 2: CONTRACTOR shall ensure that signals to/from MCC/Switchgear are isolated from high voltage and their voltage levels are not greater than 24 VDC.</Text><Text id="18709" page="20">All instrument cables used for intrinsic safe I/O, vibration/frequency inputs, milli-volt signals, RTD signals, thermocouple signals, custody measurement signals etc shall be provided with individually and collectively screen with drain wire. All other instrument cables shall be provided with collective screen with drain wire.</Text><Text id="18710" page="20">Refer to Appendix 3 for construction details of various Cable Types. Summary of Cable types is as follows:</Text><Text id="18711" page="21">Cable Construction Onshore Instrument and Control cable design and construction shall comply with BS EN 50288.</Text><Text id="18712" page="21">Offshore Instrument and Control cables design and construction shall comply with IEC 60092, BS 6883 and BS 7917.</Text><Text id="18713" page="21">Refer to Appendix 3 for construction details of each cable type. 10.3.1 Conductors</Text><Text id="18714" page="21">Conductors, with exception of thermocouple extension and compensating cables, shall be circular and multi-stranded tinned annealed copper wires conforming to IEC60228, Class 2.</Text><Text id="18715" page="21">Conductors for thermocouple extension and compensating cables shall be solid annealed type (Class 1), material and construction in accordance with IEC 60584-3.</Text><Text id="18716" page="21">For temperature ratings up to 90°C the cable core insulation material shall be Halogen Free Ethylene Propylene Rubber (EPR) or Cross-Linked Polyethylene (XLPE). For Fire Resistant cables, insulation shall be Halogen Free Ethylene Propylene Rubber with Mica Glass Tape (MGT EPR) or Cross-Linked Polyethylene with Mica Glass Tape (MGT XLPE).</Text><Text id="18717" page="21">For operating temperature up to 180°C, the Halogen Free Silicone (S95) or equivalent insulation and sheath material cables shall be used. For operating temperature up to 250°C, the insulation material PTFE</Text><Text id="18718" page="22">or Mica glass with glass fibre braid shall be used. To enhance the heat resistance capacity of the cables suitably treated glass fibre braid shall be applied over insulation and sheath material.</Text><Text id="18719" page="22">Core insulation shall be extrusion type and shall be applied closely to the conductor. It shall be possible to remove the insulation without damaging the conductor or its metal coating. The average thickness of insulation shall not be less than 0.7 mm. This thickness does not include any separator or organic tape(s) (MGT and/or glass fibre braid) applied over the conductor.</Text><Text id="18720" page="22">10.3.3 Core Identification Instrument signal and control cables cores shall be identified by insulation colour as follows:</Text><Text id="18721" page="22">For the multi-pair/ triad / quad cables, the pair / triad / quad numbers shall be additionally printed on the insulation of each core.</Text><Text id="18722" page="22">For multi-core cables containing more than four cores, the cores shall be numbered sequentially, starting with number one (1) printed in a colour contrasting with that of the insulation.</Text><Text id="18723" page="22">Thermocouple extension/compensation cables cores shall be identified by insulation colour as per IEC 60584-3 as follows:</Text><Text id="18724" page="22">Multi-pair thermocouple cables shall be identified by having the same ‘pair’ number printed in a contrasting colour on the insulation of each core.</Text><Text id="18725" page="22">Twisted pair/triad/quad cables shall be used for transmission of all instrumentation signals. For Pair / Triad / Quad formation, the cores shall be twisted together in concentric layers with either left hand or right hand lay to form a pair, triad or quad cable.</Text><Text id="18726" page="23">The lay length of a pair, triad or quad shall not exceed 100 mm for conductor size up to 1.5 mm2 nor 150 mm for conductor size 2.5 mm2.</Text><Text id="18727" page="23">A non-hygroscopic binder tape(s) shall be helically applied (providing 100% coverage with 25% overlap) over each pair, triad or quad.</Text><Text id="18728" page="23">For cables with individual screens, each pair / triad / quad shall be provided with a laminated electrostatic screening tape applied with the metallic side in electrical contact with a drain wire.</Text><Text id="18729" page="23">The drain wire shall be 0.5 mm² size minimum and constructed with stranded tinned annealed copper material. Screen shall provide 100% coverage with minimum overlap of 25% of its width.</Text><Text id="18730" page="23">The laminated electrostatic screening tape shall be of aluminium material bonded to polyester (Mylar Tape) having a minimum thickness of aluminium of 0.008 mm and a minimum thickness of polyester of 0.010 mm.</Text><Text id="18731" page="23">The individual screens shall be electrically isolated both from each pair / triad / quad and also electrically isolated from the overall screen.</Text><Text id="18732" page="23">A polyester tape of 0.050 mm nominal thickness shall be applied over the screen with a minimum overlap 20% of its total width, in order for the screen to be insulated from the remaining cable components.</Text><Text id="18733" page="23">The multi-pairs / triads / quads of the cables shall be assembled in concentric layers using either an unidirectional or reverse lay. Cable fillers shall be solid, non-hygroscopic. They shall fill the cross section such that the transmission of gas and hydrocarbons along the length of the cable, under normal pressure, is not possible.</Text><Text id="18734" page="23">The overall screen of the cable shall be provided with drain wire and the construction of overall screen shall be similar to the individual screen.</Text><Text id="18735" page="23">Overall binder tape(s), non-hygroscopic, shall be helically applied similar to individual binder (providing 100% coverage with 25% overlap) over the multi-pair / triad / quad.</Text><Text id="18736" page="23">Inner sheath material shall be Low Smoke Zero Halogen Flame Retardant Compound. Inner sheath shall be suitable for specified service, operating temperatures, site conditions and cable design standard indicated in cable data sheets. Inner sheath shall be extrusion type.</Text><Text id="18737" page="23">The lead sheath or multilayer sheath shall provide a barrier against moisture, chemicals, water, solvents, environment and hydrocarbon oil attacks.</Text><Text id="18738" page="23">All onshore underground buried cables shall be provided with Lead Sheath as a moisture and chemical barrier in accordance with BS EN 50288 and shall comply to EEMUA 133 for lead quality. Alternatively, Aluminum/high density polyethylene/polyamide (AL/HDPE/PA) multi-layer inner sheath can be acceptable subject to COMPANY prior approval. VENDOR shall provide ‘Type Test’ certificates, from a test house acceptable to COMPANY, for AL/HDPE/PA multi-layer inner sheath cables to validate degree of ingress protection against water, organic and non-organic chemicals.</Text><Text id="18739" page="23">10.3.7 Bedding Layer The bedding layer shall be provided between lead sheath and armour for underground cables. The material of construction for the bedding layer shall be same as that of the inner sheath material. 10.3.8 Steel Wire Armour Armored cable shall have Galvanized Steel Wire Armour under outer sheath.</Text><Text id="18740" page="24">The galvanized steel wire armour shall comply to requirements of EN 10257-1 and, EN 10218-1. The coating of steel wire shall comply with the requirements of EN 10244-2. 10.3.9 Outer Sheath</Text><Text id="18741" page="24">Outer sheath material shall be minimum PVC or better and comply with this specification requirements. Outer sheath shall be Low Smoke Zero Halogen Flame Retardant Compound. Outer sheath shall be suitable for specified service, operating temperature, site conditions and cable design standard indicated in cable data sheets. Outer sheath shall be extrusion type.</Text><Text id="18742" page="24">Outer sheath shall be anti-vermin impregnated and UV-resistant. Outer sheath shall be heat, oil and flame retardant (HOFR).</Text><Text id="18743" page="24">Outer sheath material shall be minimum PVC or better and comply with this specification requirements. The colour of outer sheath shall be as follows:</Text><Text id="18744" page="25">Cable Performance requirements 10.4.1 Physical and Mechanical Characteristics.</Text><Text id="18745" page="25">The physical and mechanical characteristics of the cable core, insulation, screens, sheaths, bedding, filler and armour materials shall be in accordance with the relevant standards that are referred to each type of cables.</Text><Text id="18746" page="25">The electrical characteristics such as resistance, inductance and capacitance of the complete cables shall be in accordance with the relevant standards that are referred to each type of cables.</Text><Text id="18747" page="25">The electrical parameters such as L/R ratio and Mutual Capacitance for the I.S. cables shall be as per Control Systems VENDOR recommendation based on I.S. circuit design, which shall be specified in the project specific data sheet.</Text><Text id="18748" page="25">Flame retardant cables shall pass the tests as defined in IEC 60332-3-22 Category A (reduced propagation). In addition to above, refer to BS 6883 for Offshore flame retardant cables.</Text><Text id="18749" page="25">Fire resistant cables shall pass the tests as defined in IEC 60331-1, 2 &amp; 3. Fire resistant test and mechanical shock test shall be carried out simultaneously with the flame temperature of 830°C and application time of 90 minutes.</Text><Text id="18750" page="25">In addition to above, refer to BS7917 for Offshore fire resistant cables. 10.4.5 Smoke Emission Level.</Text><Text id="18751" page="25">Smoke emission test shall be carried out in accordance with IEC 61034-1 &amp; 2 and the smoke generated shall not result in transmittance value of lower than 60%.</Text><Text id="18752" page="25">Acid gas emission level test shall be carried out in accordance with IEC 60754-1 requirements. The maximum level of hydrogen chloride (HCl) emission during the combustion of insulation, sheath, bedding and filler materials shall not be greater than 0.5%.</Text><Text id="18753" page="25">10.4.7 Corrosivity Level pH and conductivity tests shall be carried out in accordance with IEC 60754-2 requirements. 10.4.8 Fluorine Content Level Fluorine content test shall be carried out in accordance with IEC 60684-2 requirements. 10.4.9 Oxygen Index. As a minimum, the oxygen index value for cable shall be greater than 32. 10.4.10 Oil Resistance Characteristics.</Text><Text id="18754" page="25">Test method and its performance test results for the aboveground cables shall be as per IEC 60811 and Table 9 of IEC 60092-360 respectively.</Text><Text id="18755" page="25">Test method for the underground cables shall be as per EN 60811 and its performance test results shall be as per EN 50289 and EN 50290.</Text><Text id="18756" page="26">Refer to BS7655 Section 2.6 for the test requirements and the application details of Offshore / Marine oilresisting cable, cross-linked elastomeric insulating and sheathing compound types SW1, SW2, SW3 and SW4. Refer to BS7655 Section 1.4 for oil-resisting compound type OR1.</Text><Text id="18757" page="26">10.4.11 Resistance to Solar Radiation. Solar radiation (UV rays) resistant of the cables shall be tested in accordance with EN 50289-4-17. 10.4.12 Resistance to Heat Characteristics.</Text><Text id="18758" page="26">Thermal ageing tests for the cable insulation and sheaths, such as ageing in an air oven and ageing in an air bomb test, shall be carried out in accordance with IEC 60811-401.</Text><Text id="18760" page="26">Cables resistant to water treeing characteristics shall be tested in accordance with the relevant method specified in cable construction standards.</Text><Text id="18761" page="26">10.4.14 Resistance to Drilling Fluids Drilling fluids resistant of the cables shall be tested in accordance with IEC 60092-360. 10.4.15 Resistance to Chemicals and Solvents</Text><Text id="18762" page="26">Cables resistant to Chemicals and solvents test shall be carried out in accordance with the relevant standards that are referred in cable construction standards.</Text><Text id="18763" page="26">10.4.16 Ozone Resistance Characteristics Ozone resistance test for insulation and sheath(s) shall be carried out in accordance with IEC 60811-403.</Text><Text id="18764" page="26">Marking and Traceability Requirements Cables shall be supplied in continuous drum lengths without any cable or conductor joints. No negative tolerance on drum length is permissible. 10.5.1 Cable Marking</Text><Text id="18765" page="26">The outer sheath of cable shall be embossed legibly every one meter along the entire cable length, on two sides, with the following data as a minimum:</Text><Text id="18766" page="26">(a) Manufacturer Name and year of manufacture (b) Applicable Cable Standard (EN 50288-7 etc.) (c) Flame retardant as per IEC 60332-3 or Fire Resistant as per IEC 60331 (d) Voltage rating (300V/500V etc.) (e) Cable Type and Designation (construction) or Fibre quantity, size and type (f) Cable length (in metres) and sequential length mark (g) Number of cores (or pairs or fibres) and conductor size (CSA) (h) Circuit Integrity Class (for Fire Resistant Cables)</Text><Text id="18767" page="26">The letters and figures on the outer sheath shall consist of upright block characters with a minimum height of 3 mm.</Text><Text id="18768" page="27">For FO cables, each buffer tube of the outdoor cable shall be a different colour in accordance with VENDOR standard.</Text><Text id="18769" page="27">The VENDOR shall include the following additional cable information on the cable datasheet for each cable type:</Text><Text id="18770" page="27">(a) Conductor resistance at 35°C ohms/1000 meters. (b) Impedance at 50Hz in ohms/1000 meters. (c) Mutual capacitance at 50Hz in nanofarads/1000 meters. (d) L/R ratio in micro henry/ohm (e) Weight in Kg/1000 meters. (f) Diameter of cable under armour and tolerance. (g) Thickness of armour and tolerance. (h) Bending radius at minimum installation temperature. (i) Minimum installation temperature. (j) Overall Cable Diameter. (k) Mutual inductance in millihenry/1000meters.</Text><Text id="18771" page="27">Refer to Appendix1 for the cable datasheet and Appendix 2 for the cable designation/numbering requirements.</Text><Text id="18772" page="27">All cables shall be supplied and delivered in maximum manufacturing cable drums length, continuous lengths on non-returnable cable drums. VENDOR shall specify their standard production length for the selected cable types.</Text><Text id="18773" page="27">Cable ends shall be sealed and fixed to the drum. Cable drums shall be fitted with battens, fixed around the entire periphery of the drum.</Text><Text id="18774" page="27">All cable drums shall have their identification number or reference clearly stenciled on the outside of both flanges.</Text><Text id="18775" page="27">Each cable drum shall be fixed with clear weatherproof identification labels. Labels shall be robust and non-fading. All cable drums labels shall provide the following information as a minimum:</Text><Text id="18776" page="27">(a) Manufacturer’s name and year of manufacture (b) Drum identification number (COMPANY and VENDOR&apos;s numbers) (c) Purchase order number and project name (d) Purchase order item number (or Stock code Number as stated in Material Requisition) (e) Voltage rating (f) Number of cores (or pairs or fibres) and conductor size (CSA) (g) Cable quantity (length) (h) Cable type and Designation (construction) or Fibre quantity, size and type (i) Length of cable on the drum (in metres)</Text><Text id="18777" page="28">(j) Total weight of cable and drum (kg) (k) Site location</Text><Text id="18778" page="28">VENDOR shall produce a drum schedule for the scope of supply on each project and shall identify each cable length. All drum lengths shall be continuous. Cable or conductor jointing in any form is unacceptable.</Text><Text id="18779" page="28">VENDOR shall also identify where multiple cable designations have been applied to a single cable length on the drum and identify each designated cable length to allow for unreel &amp; cable cutting after delivery, where appropriate.</Text><Text id="18780" page="29">Selection of Fibre Optic (FO) cables and its design shall comply with all parts of IEC 60793, IEC 60794, IEC 61281-1, IEC 61282 and ITU-T G.652.</Text><Text id="18781" page="29">Fibre optic cable properties and construction shall be as follows:</Text><Text id="18782" page="29">A minimum of 2 x 24 core Single Mode FO Cable shall be provided for each system, unless otherwise specified by the project requirement.</Text><Text id="18783" page="29">All FO cables construction shall be based on the ‘Loose Tube’ type. Loose tube cables are characterized by loose fitting, buffer or gel-filled tubes into which the fibres are placed.</Text><Text id="18784" page="29">Each individual fibre shall be protected by a loosely fitting, colour coded, buffer tube. The tubes shall be extruded from PolyButylene Terephthalate (PBT) or Allied ‘HALAR’ fluoroplastic or an acceptable equivalent. The outside diameter of the buffer tubes shall not exceed 3.0 mm (0.118 inches). The buffer tubes shall be twisted around the central member with a lay which will result in each buffer tube being</Text><Text id="18785" page="30">approximately two percent longer than the central member. Each buffer tube, as well as the core interstices, shall be flooded with a filling compound to minimize water entry and migration. The compound shall be stable, moisture resistant, non-toxic, electrically non-conducting and compatible with all other cable components.</Text><Text id="18786" page="30">No fibre splices are allowed in a length of completed cable.</Text><Text id="18787" page="30">FO Cables shall be given buckle resistance by a glass reinforced plastic (GRP) rod or equivalent, through the center of the cable. An Aramid wrap and/or E-glass yarn and polyester tape around the buffer tubes provides tensile strength.</Text><Text id="18788" page="30">The inner and outer sheath material shall be LSZH Flame Retardant compound. Wherever required, the FO cable design shall also be fire resistant to IEC 60331.</Text><Text id="18789" page="30">All outdoor FO cables shall have a twisted steel wire armour in addition to the dual jacketing structure.</Text><Text id="18790" page="30">The cable shall be designed so that the fibers will not be stressed when the cable is installed with a minimum bending radius of 25 cm.</Text><Text id="18791" page="30">Fibre Optic Cable shall have fibre colours and buffer tube colours in accordance with EIA/TIA-598.</Text><Text id="18792" page="31">suitable for specified service, operating temperature, site conditions and cable design standard indicated in cable data sheets. Outer sheath shall be extrusion type.</Text><Text id="18793" page="31">Outer sheath shall be anti-vermin impregnated and UV-resistant. Outer sheath shall be heat, oil and flame retardant (HOFR).</Text><Text id="18794" page="31">Outer sheath material shall be minimum PVC or better and comply with this specification requirements.</Text><Text id="18796" page="32">The VENDOR shall supply Instrument and Control cables in accordance with technical requirements in this specification and project specific Purchase Order documentation.</Text><Text id="18797" page="32">The VENDOR scope of supply shall include but not be limited to:</Text><Text id="18798" page="32">1. Supply of cables as per types and quantities listed in project purchase order</Text><Text id="18799" page="32">2. Design, fabrication, assembly and testing of cables</Text><Text id="18800" page="32">3. Submission of VENDOR’s Design Specification for cable design, fabrication and testing for CONTRACTOR/COMPANY approval</Text><Text id="18804" page="32">Equipment and materials shall only be purchased from Vendors approved by ADNOC Category Management. This approval indicates that the VENDOR has an approved Quality management system and a proven track record in supply of this equipment and material type.</Text><Text id="18805" page="32">COMPANY/CONTRACTOR reserves the right to inspect materials and workmanship at all stages of manufacture and to witness any or all tests.</Text><Text id="18806" page="32">VENDOR shall comply to Criticality Rating for Equipment outlined in respective ADNOC Group Company’s Quality System Specifications for requirements of production checks, shop inspection, testing and material certification.</Text><Text id="18807" page="32">The VENDOR shall provide equipment and material inspection and test reports as per approved Inspection and Test Plan by CONTRACTOR.</Text><Text id="18808" page="32">VENDOR shall provide all material Test Certificates as per Supplier Document Register and Schedule (SDRS) provided in Purchase Order.</Text><Text id="18809" page="33">15 INSPECTION &amp; TESTING REQUIREMENTS The VENDOR shall be responsible for workmanship, testing and quality assurance of the material supplied.</Text><Text id="18810" page="33">All formal testing will be conducted in accordance with written Inspection and Test Plan (ITP) test procedure. The test procedures shall be furnished by the VENDOR to the CONTRACTORS at least two months prior to the associated test for approval.</Text><Text id="18811" page="33">All the cables shall be subjected to routine tests and the test records/reports shall be submitted for CONTRACTOR/COMPANY review.</Text><Text id="18812" page="33">The test requirements, types of tests and test procedures shall be specified in the Inspection and Test Plan (ITP), submitted and agreed with the COMPANY.</Text><Text id="18813" page="33">COMPANY, CONTRACTOR and/or assigned Third Party Inspector for the specific project shall witness the inspection and tests as per approved project specific Inspection and Test Plan (ITP) and QA/QC procedure. The COMPANY shall be informed of testing schedule with an advance notice as per project specific contract requirements.</Text><Text id="18814" page="33">The inspection and acceptance of reports and certificates shall in no way release VENDOR from final guarantee with regard to materials, workmanship and performance of the material inspected.</Text><Text id="18815" page="33">The VENDOR shall be responsible for inspection and quality assurance of the materials and standard of workmanship furnished. Testing and inspection will be carried out and witnessed by the CONTRACTOR and COMPANY representatives at various stages as the equipment is manufactured and assembled, at locations as detailed below:</Text><Text id="18816" page="33">(1) Shop Inspection: Conducted at the manufacturing facility of VENDOR</Text><Text id="18817" page="33">(2) Factory Acceptance Test: Conducted at the manufacturing facility of VENDOR</Text><Text id="18818" page="33">(3) Site Delivery Acceptance Test and Inspection: Conducted at the job site.</Text><Text id="18819" page="33">Each formal acceptance test shall be signed by VENDOR, CONTRACTOR and COMPANY representatives at the successful completion of the test(s).</Text><Text id="18820" page="33">Inspection and Testing shall be performed only when all the technical documents from the VENDOR are reviewed and approved by COMPANY. Before commencement of any test, copies of all relevant drawings, certificates and specifications shall be made available to the COMPANY.</Text><Text id="18821" page="33">Provision of suitable test gear and accessories, if any, for the test shall be the responsibility of the VENDOR.</Text><Text id="18822" page="33">All the punch points highlighted during Factory Acceptance Test (FAT) shall be cleared in agreement with COMPANY.</Text><Text id="18823" page="33">Material shall be dispatched only after obtaining dispatch clearance from the CONTRACTOR/COMPANY. All the necessary documents including FAT punch points clearance report and material test certificates shall be submitted to CONTRACTOR/COMPANY, while requesting the dispatch clearance.</Text><Text id="18824" page="34">During the FAT, the following tests are to be carried out at VENDOR works for witness by representatives of COMPANY, CONTRACTOR and Third-Party Inspector.</Text><Text id="18825" page="34">Below (S) means ‘Sample Test during FAT (samples taken from drum)’ and (D) means ‘Drum Test for the complete length of cable in the drum’.</Text><Text id="18826" page="34">(a) Dimensions and Tolerances Check (S &amp; D) (b) Voltage test (S) (c) Continuity test (D) (d) Insulation resistance test (S &amp; D) (e) Flame Retardant test (S) (f) Fire with mechanical shock resistant test (S) (g) Fire tests including pH &amp; Conductivity, Fluorine content, Acid gas emission test (S) (h) Oxygen index test (S) (i) Bending test (S) (j) Conductor resistance test. including drain wire (S &amp; D) (k) Electrical Characteristics L/R ratio &amp; Capacitance (S) (l) Resistant to Fire with water spray test (S) (m) Thermal Ageing test (S) (n) Smoke Density test (S) (o) Ozone Resistance Test (S) (p) Oil Resistant Test (S) (q) UV resistant Test S) (r) Drilling Fluid Resistance test (S) (s) High Temperature Test (for siliconee insulated cables) (S) (t) Watering Treeing Test (S) (u) Galvanizing Test (Dipping Test) (S) (v) Mechanical Tests including impact resistance test (S)</Text><Text id="18827" page="34">Where there are no standard test procedures available in the referenced IEC / BS standards for some specific tests, test procedures and methods shall be developed by VENDOR and agreed with COMPANY.</Text><Text id="18828" page="34">Details such as cable diameter shall be submitted to the COMPANY during the course of manufacture to enable designing and/or selection of the cable gland.</Text><Text id="18829" page="34">After testing, the ends of the cable shall be sealed with approved caps to prevent the ingress of moisture. The test reports shall contain as a minimum: (a) The anticipated (theoretical) values. (b) The tolerances permitted.</Text><Text id="18830" page="35">(c) The results of the measurements, including any intermediate value, which has caused a temporary rejection.</Text><Text id="18831" page="35">(d) Explanation of any calculations. Fibre Optic Cables</Text><Text id="18832" page="35">Tests shall be carried out on all fibre optic cables according to EIA TIA-455 to verify attenuation and bandwidth specifications at the manufacturer’s premises.</Text><Text id="18833" page="35">Routine tests and sample tests shall be carried out on all cables produced and shall be in accordance with IEC 60793, IEC 60794 and IEC 61280.</Text><Text id="18834" page="35">The routine type tests shall include the following: (a) OTDR measurements (b) End to end attenuation (c) Macrobending loss (d) Chromatic dispersion (e) Stress corrosion susceptibility (f) Bandwidth (g) Tensile strength (h) Fibre proof tests (i) Fibre geometry Additional tests shall be carried out to verify the FO cable properties including the following: (a) Fire resistance test to IEC 60331 and EN 50200 for fire resistant cables. (b) Flame retardant test IEC 60332 for flame retardant cables. (c) Bending test for all cables. (d) Cable Bending Radius (IEC 60794-1-2-E11 and -E6). (e) Tensile Force (IEC 60794-1-2-E1). (f) Torsion Strength (IEC 60794-1-2-E7). (g) Crush Resistance (IEC 60794-1-2-E3). (h) Impact Resistance (IEC 60794-1-2-E4). (i) Kink Resistance (IEC 60794-1-2-E10). (j) Water Penetration (IEC 60794-1-2-F5).</Text><Text id="18835" page="35">The FAT will include the inspection, testing and acceptance of Fibre Optic Cables as per EIA/TIA and ITU standards. In particular, the attenuation test shall be done on 100% fibres.</Text><Text id="18836" page="35">At the satisfactory conclusion of the FAT, a factory Certificate of Acceptance shall be provided by the VENDOR for signature by COMPANY and CONTRACTOR.</Text><Text id="18837" page="36">At the satisfactory conclusion of the Site Acceptance Test (SAT), a Provisional Acceptance Certificate shall be prepared by CONTRACTOR. Along with all test reports and certificates, a Certificate of Provisional Site Acceptance, which COMPANY shall review and approve.</Text><Text id="18838" page="36">The VENDOR shall assume unit responsibility and overall guarantee for the equipment package and associated materials.</Text><Text id="18839" page="36">The VENDOR shall transmit all relevant purchase order documents including specifications to his SUBCONTRACTORS.</Text><Text id="18840" page="36">It is the VENDOR&apos;S responsibility to enforce all Purchase Order and Specification requirements on his SUBCONTRACTORS.</Text><Text id="18841" page="36">The VENDOR shall submit all relevant SUBCONTRACTOR drawings and engineering data to the CONTRACTOR.</Text><Text id="18842" page="36">The VENDOR shall obtain and transmit all SUBCONTRACTORS warranties to the CONTRACTOR/COMPANY, in addition to the system warranty.</Text><Text id="18844" page="36">18 PACKING, PRESERVATION &amp; SHIPMENT Packing and Shipping</Text><Text id="18845" page="36">Preparation for shipment shall be in accordance with purchase order Preservation and Export Packing requirements. VENDOR shall be solely responsible for the adequacy of the preparation for shipment provisions with respect to materials and application, and to provide equipment at the destination in ex-works condition when handled by commercial carriers. Adequate protection shall be provided to prevent mechanical damage and atmospheric corrosion in transit and at the jobsite. Preparation for shipment and packing will be subject to inspection and rejection by COMPANY&apos;S/CONTRACTOR&apos;S inspectors. All costs occasioned by such rejection shall be to the account of the VENDOR. Cables shall be export quality packed to prevent damage during transit, lifting, or unloading. Pieces of equipment and spare parts shall be identified by item number and service and marked with CONTRACTOR&apos;S order number, tag number, and weight, both inside and outside of each individual package or container. A bill of material shall be enclosed in each package or container of parts. One complete set of the installation, operation, and maintenance instructions shall be packed in the boxes or crates with equipment. This is in addition to the number called for in the Purchase Order.</Text><Text id="18846" page="36">All kinds of regulatory / non-regulatory approvals and procedures required for shipping shall be in the scope of CONTRACTOR / VENDOR.</Text><Text id="18848" page="36">Cables shall be protected to withstand ocean transit and extended period of storage at the jobsite for a minimum period of 18 months. Cables shall be protected to safeguard against all adverse environments, such as humidity, moisture, rain, dust, dirt, sand, mud, salt air, salt spray, and seawater. All cables shall be preserved, and export packed in accordance with project specifications.</Text><Text id="18849" page="37">Adequate protection shall be provided to prevent mechanical damage and atmospheric corrosion in transit and at the worksite. The cable drums shall be lagged or covered with suitable material, to provide physical protection during transit, ordinary storage and handling operations.</Text><Text id="18850" page="37">The ends of Control and Instrument cables shall be properly sealed for transport by sea and for storage under desert conditions. Cable ends shall be fitted with heat shrink end cap to prevent entry to moisture inside the cable.</Text><Text id="18851" page="37">The VENDOR shall provide preservation plan to protect and ensure the integrity of equipment and materials during the period that starts when the equipment and materials is prepared for the first shipment from the point of origin and ends at the completion of project commissioning and start-up. The plan shall identify protective measures to be implemented during each phase of the project, inclusive of ambient conditions. The completion plan shall be submitted to COMPANY for review and comment no later than 90 days prior to the first shipment of equipment and materials from the factory.</Text><Text id="18852" page="37">Preparation for shipment and packing will be subject to inspection and rejection by COMPANY inspectors.</Text><Text id="18853" page="37">19 COMMISSIONING Not Applicable. 20 TRAINING Not Applicable. 21 DOCUMENTATION/MANUFACTURER DATA RECORDS</Text><Text id="18855" page="37">VENDOR shall submit the type and quantity of drawings and documentation for COMPANY/CONTRACTOR authorization or information as per Supplier Document Register and Schedule (SDRS) provided in Purchase Order.</Text><Text id="18856" page="37">The VENDOR shall provide all standard and project-specific documentation and material data sheets. This information shall provide complete documentation for the cables in sufficient detail to permit supply, installation, proof testing, maintenance and replacement of the control and instrumentation cables.</Text><Text id="18857" page="37">Mutual Agreement on document list and documents issue dates shall be an integral part of Purchase Order.</Text><Text id="18858" page="37">Comments made by COMPANY/CONTRACTOR on drawing submittal shall not relieve VENDOR of any responsibility in meeting the requirements of this specification. Such comments shall not be construed as permission to deviate from requirements of the Purchase Order unless specific and mutual agreement is reached and confirmed in writing.</Text><Text id="18859" page="37">All drawings, documents, information, correspondence, test reports, operating and maintenance instructions and like items shall be in the English language.</Text><Text id="18860" page="37">All documents and drawings issued by the VENDOR shall be produced in an electronic format compatible with Microsoft Office computer software. Documentation shall also be provided in Native format, in order to allow company to update during operational upgrade and future projects. VENDOR shall provide final documentation on DVD-ROM with search and retrieval capabilities.</Text><Text id="18861" page="37">All drawings and datasheets shall be prepared and submitted in accordance with recognized standards. Every effort shall be made to minimize the total number of drawings and datasheets prepared by use of common drawings or datasheets, where practicable without loss of clarity.</Text><Text id="18862" page="37">Each drawing or datasheet shall be provided with a block in the bottom right-hand corner incorporating the following information:</Text><Text id="18863" page="38">(a) Official trade name of the VENDOR. (b) VENDOR’S drawing or material reference number. (c) Drawing title giving the description of contents whereby the drawing can be identified. (d) A symbol or letter indicating the latest issue or revision. (e) PO number and item tag numbers.</Text><Text id="18864" page="38">Revisions to drawing or datasheet shall be identified with symbols adjacent to the alterations, a brief description in tabular form of each revision shall be given, and if applicable, the authority and date of the revision shall be listed. The term “Latest Revision” shall not be used.</Text><Text id="18866" page="38">The VENDOR and CONTRACTOR shall supply complete final cable documentation, which shall include but not limited to the following:</Text><Text id="18867" page="38">(a) Technical Data Sheets &amp; Specifications (b) Material Test Certificates (c) Dimensional Details (d) Installation Test Certificates</Text><Text id="18868" page="38">VENDOR shall provide warranty support for a period of two years following cable installation and plant commissioning at site. Warranty shall apply to defective material workmanship and cable failures. The cost of diagnostics and/or correction of any warranty items shall be borne by the VENDOR.</Text><Text id="18869" page="38">The VENDOR shall guarantee that supplied cables last till design life for 30 years.</Text><Text id="18871" page="39">Refer following Appendices in Section E for cable data sheet, numbering method and construction requirements:</Text><Text id="18872" page="39">Appendix 1: CABLE DATASHEET Appendix 2: CABLE DESIGNATION Appendix 3: TYPICAL CONSTRUCTION DETAILS FOR CABLES</Text><Text id="18874" page="40">The cable details listed below, items 1 to 71 including the tick-boxes &amp; the data values, shall be provided/submitted by the VENDOR on a datasheet for each cable.</Text><Text id="18876" page="40">2. Cable Quantity required (metres): ………………………………3. Manufacturer: ……........................... 4. Purchase Order Number and Date: ………………………………………………. dd/mm/yyyy 5. Installation: Aboveground Underground Indoor Marine</Text><Text id="18877" page="40">6. Manufacturing Standard IEC 60092 BS EN 50288 BS 6883 BS 7917</Text><Text id="18878" page="40">7. Cable characteristic: Flame Retardant Fire Resistant High Temperature</Text><Text id="18881" page="40">(Analog, RTD, Thermocouple, Vibration, Speed, Digital Input, Digital Output, SOV, F&amp;G, ESD, Comms, Other – please specify)</Text><Text id="18882" page="40">11. CSA of Conductor: 1.0mm² 1.5mm² 2.5mm² Other ( )</Text><Text id="18883" page="40">12. Conductor Class: Class 1 (solid) Class 2 (stranded)</Text><Text id="18884" page="40">13. Conductor Insulation Material Halogen Free Flame Retardant as per IEC 60092, BS EN 50290: EPR XLPE MGT EPR MGT XLPE Other __________________ XL SILICONE RUBBER (S95) MGT XL SILICONE RUBBER (S95)</Text><Text id="18885" page="40">14. Conductor Insulation Material Halogen Free Flame Retardant BS 6883 &amp; BS 7917: GP4 GP 5 GP6 GP7 Other ___________________</Text><Text id="18886" page="41">Black, White Black, White, Red Black, White, Red, Blue Other……………………..</Text><Text id="18887" page="41">18. Lay length (Number of twists per Metre): _____</Text><Text id="18888" page="41">19. Screen/Foil: Individual Overall Individual &amp; Overall N/A</Text><Text id="18889" page="41">20. Screen material: Aluminium bonded to polyester (Mylar) tape Braid Other……….</Text><Text id="18891" page="41">22. Inner Sheath material as per IEC 60092, BS EN 50290: Halogen Free Flame Retardant Compound Other…….</Text><Text id="18892" page="41">23. Inner Sheath material Halogen Free Flame Retardant Compound (BS 6883-5.3 or BS 7917-5.3): SW2 Other……………</Text><Text id="18893" page="41">24. Thickness of inner sheath: …………………. 25. Inner Sheath colour: …………………………</Text><Text id="18894" page="41">Unarmoured GSWB GSWA Foil GSW Diameter……..…… 27. Bedding material: Rubber, Type SHF2 HFFR Compound Other…………………. 28. Moisture and Chemical barrier: Lead sheath AL/HDPE/PA Multi-layer Sheath N/A</Text><Text id="18895" page="41">29. Thickness of lead sheath………………………. 30. Thickness of multi-layer sheath………………</Text><Text id="18896" page="41">31. Outer Sheath material as per IEC 60092, BS EN 50290: Halogen Free Flame Retardant Compound Other………….</Text><Text id="18897" page="41">32. Outer Sheath material Halogen Free Flame Retardant Compound (BS 6883-4.2 or BS 7917-4.2): SW2 Other……………………</Text><Text id="18898" page="41">33. Thickness of outer sheath: …………………. 34. Outer Sheath colour: ………………………</Text><Text id="18899" page="42">36. Special Requirements: …………………………………………………………………………………………... (Excessive Sunlight, Resistance to Chemicals, Corrosive Environment, High Temperature)</Text><Text id="18900" page="42">37. Thermocouple Tolerance Class: Class 1 Class 2 N/A 38. Total Cable Length (metres): ……………………………………………………….. 39. Drum Length (metres): ………………………………………………………………. 40. Cable Weight (Kg/Km): …………… 41. Cable and Drum combined Weight (Kg): …………… 42. Conductor Max Temperature: Normal operation………….°C Fault Condition…………….°C. 43. Cable Min. Installation Temperature: …………………………...°C 44. Bending Radius (mm) at minimum install temperature: …………………….……mm at …….…°C. 45. Cable Diameter (mm) and Tolerances: - Under Armour……………………………………..</Text><Text id="18902" page="42">- Bedding…………………………………………….. - Sheath…….………………………………………… - Armour………………………………………………. - Others………………………………………………..</Text><Text id="18903" page="42">47. Recommended Gland type and size: ………………………………………………………………. 48. Resistance Max. at 90°C (Ohm/Km): ………………….. 49. Reactance (Ohm/Km): ……………… 50. Inductance Max. up to 1 KHz (mH/Km): ………………………………………… 51. Impedance Max. @ 90°C &amp; 60 Hz (Ohm/Km): …………………………………. 52. Conductor Loop Resistance per Km @ 35°C: …………………… @ 60°C: ………………………. 53. Max. Loop Self Inductance per Km up to 1 Khz (mH): …………………………. 54. Max. L/R ratio (μH/Ω): ………………………………………………………………… 55. Max. Mutual Capacitance (μF/Km): ………………………………………………… 56. Max. Capacitance Core to Earth (μF/Km): ……………… Core to Core (μF/m): ………………….. 57. Voltage Drop (per amp per Km): ……………………………………………………</Text><Text id="18904" page="43">58. Short Circuit Rating (kA) at 250°C / sec. duration: ……………………………… 59. Smoke Emission level: …………………………………… …………………………. 60. Corrosive and Acid Gas Emission level: …………………………………………. 61. pH and Conductivity levels: …………………………………………………………. 62. Fluorine content level: ………………………………………………………………… 63. Oxygen Index value: …………………………………………………………………… 64. Oil resistance characteristics: Yes No 65. Ozone resistance characteristics: Yes No 66. Resistance to high temperature: Yes No 67. Resistant to chemicals &amp; solvents: Yes No 68. Resistant to rodent &amp; fauna attack: Yes No 69. Resistant to mechanical damage: Yes No 70. Resistant to water treeing: Yes No 71. Resistant to drilling fluids: Yes No 72. Resistant to soil salinity: Yes No 72. Resistant to saline water ingress: Yes No</Text><Text id="18906" page="44">The Fibre Optic cable details listed below, items 1 to 48 including the tick-boxes &amp; the data values, shall be provided/submitted by the VENDOR on a datasheet for each Fibre Optic cable.</Text><Text id="18908" page="44">2. Cable Quantity required (metres): ………………………………3. Manufacturer: ……........................... 4. Purchase Order Number and Date: ………………………………………………. dd/mm/yyyy 5. Installation: Aboveground Underground Indoor Marine</Text><Text id="18912" page="44">8. Cable Temperature Range: Storage -…..…°C to +…..…°C, Operating -….….°C to +.....….°C</Text><Text id="18914" page="44">(Comms Backbone, Data trunk, Direct Burial, Cable tray or Duct installation, Automation, Subsystem, Other)</Text><Text id="18915" page="44">10. Mode/Fibre Type: OM1 OM2 OM3 OM4 OS2</Text><Text id="18916" page="44">11. Optical Performance: Bandwidth………..…MHz@ 850 nm Attenuation………….…dB/km Optical Performance: Bandwidth………..…MHz@ 1300 nm Attenuation………….…dB/km Optical Performance: Bandwidth………..…MHz@ ……. nm Attenuation………….…dB/km Optical Performance: Bandwidth…………..…GHz Attenuation………….…dB/km@..................nm</Text><Text id="18918" page="44">13. Strength Member Material: Central………………………. Overall…………………………….. (GRP rod, Fibreglass, E-glass, E-glass and Aramid Yarn, Aramid Yarn)</Text><Text id="18920" page="44">15. Fibre bundle Formation: No. of Fibre Cores ……..……. No. of Buffer Tubes……………</Text><Text id="18921" page="44">16. Fibre bundle Wrap / Binder material: ……………………………………………………………. (Water blocking tape, Water swellable tape, Water blocking E-glass yarn, Aramid yarn and polyester tape)</Text><Text id="18922" page="45">17. Inner Jacket Material: Halogen Free Flame Retardant Compound Other………….</Text><Text id="18923" page="45">18. Thickness of inner jacket: …………………. 19. Inner jacket colour: …………………………</Text><Text id="18924" page="45">20. Mechanical Protection: Unarmoured Corrugated Steel Tape Aluminium Tape Polyester Tape GSWA E-glass &amp; Aramid Yarn Aramid Yarn Other…………….</Text><Text id="18925" page="45">Halogen Free Flame Retardant Compound Other…………. 22. Thickness of outer jacket: …………………. 23. Outer Jacket colour: ………………………… (Orange, Aqua, Yellow, Black) 24. Halogen Emission (EN 50267-1&amp;2): 0.5% 5%</Text><Text id="18926" page="45">25. Special Requirements: …………………………………………………………………………………………... (Excessive Sunlight, Resistance to Chemicals, Corrosive Environment, High Temperature)</Text><Text id="18929" page="45">28. Cable Weight (Kg/Km): …………… 29. Cable and Drum combined Weight (Kg): ……………</Text><Text id="18930" page="45">29. Cable Min and Max. Installation Temperature: ………………°C Min …..…………...°C Max</Text><Text id="18931" page="45">30. Minimum Bending Radius at minimum install temperature: ……………… x O.D. at …….………….°C.</Text><Text id="18932" page="45">31. FO Cable Outside Diameter (O.D.): ……………… mm</Text><Text id="18933" page="45">32. Max Installation Load: ……………… N (or equivalent ……………….. Lbs)</Text><Text id="18935" page="45">34. Impact Resistance (EIA-455-25): ……………… impacts at ……………….N-m</Text><Text id="18938" page="46">37. Corrosive and Acid Gas Emission level: ………………………………………….</Text><Text id="18945" page="46">44. Resistant to chemicals &amp; solvents: Yes No</Text><Text id="18946" page="46">45. Resistant to rodent &amp; fauna attack: Yes No</Text><Text id="18949" page="47">APPENDIX 2 CABLE DESIGNATION CABLE FOR OUTDOOR ABOVE GROUND INSTALLATION</Text><Text id="18950" page="47">Instrument and Control cables (Analogue and Digital Signals) - Low Smoke Zero Halogen Flame Retardant or Fire Resistant cable types, used for above ground outdoor installation shall be identified with the following designation:</Text><Text id="18951" page="47">LSZH 1 2 3 4 5 6 7</Text><Text id="18952" page="47">Colour For example LSZH/MGT XLPE/IS &amp; OS/LZSH/GSWA/LZSH/5P/1.5 mm²/Black</Text><Text id="18953" page="47">1) Core Insulation XLPE - Flame retardant Cross (X) Linked Polyethylene MGT XLPE - Mica impregnated glass tape beneath extruded layer of XLPE EPR - Ethylene Propylene Rubber MGT EPR - Mica impregnated glass tape beneath extruded layer of EPR S95 - Cross linked Silicone Rubber with treated glass fibre braid MGT S95 - Mica impregnated glass tape beneath extruded layer of S95</Text><Text id="18954" page="47">2) Screen OS - Overall Screen IS &amp; OS - Individual and Overall Screen</Text><Text id="18955" page="47">3) Inner Jacket LZSH - Flame Retardant Low Smoke Zero Halogen Compound</Text><Text id="18956" page="47">4) Armour GSWA - Galvanised Steel Wire Armour</Text><Text id="18957" page="47">5) Outer Jacket LZSH - Flame Retardant Low Smoke Zero Halogen Compound</Text><Text id="18958" page="47">6) Number of Cores or Pairs or Triads or Quads</Text><Text id="18959" page="47">2C, 4C, 7C, 11C, 19C, 27C, 37C, 1P, 1T, 1Q 2P, 2T, 2Q 10P, 10T, 10Q 20P, 20T</Text><Text id="18961" page="47">Outer jacket colour shall be as per application.</Text><Text id="18962" page="47">1.0 mm2, 1.5mm² or 2.5mm² or state the alternative size</Text><Text id="18963" page="47">Use the “–“ (dash symbol) to indicate when the designation parameter is not applicable, as necessary for cables types without inner jacket and/or without armour.</Text><Text id="18964" page="48">CABLE SUITABLE FOR DIRECT BURIAL OR OUTDOOR USE</Text><Text id="18965" page="48">Instrument and Control cables (Analogue and Digital Signals) - Low Smoke Zero Halogen Flame Retardant or Fire Resistant cable types, used for underground or outdoor installation shall be identified with the following designation:</Text><Text id="18966" page="48">LSZH 1 2 3 4 5 6 7 8 9</Text><Text id="18967" page="48">Colour For example LSZH/MGT XLPE/IS &amp; OS/LZSH/MLS/LSZH/GSWA/LZSH/2T/2.5 mm²/Black</Text><Text id="18968" page="48">1) Core Insulation XLPE - Flame retardant Cross (X) Linked Polyethylene MGT XLPE - Mica impregnated glass tape beneath extruded layer of XLPE EPR - Ethylene Propylene Rubber MGT EPR - Mica impregnated glass tape beneath extruded layer of EPR S95 - Cross linked Silicone Rubber with treated glass fibre braid MGT S95 - Mica impregnated glass tape beneath extruded layer of S95</Text><Text id="18969" page="48">2) Screen OS - Overall Screen IS &amp; OS - Individual and Overall Screen</Text><Text id="18970" page="48">3) Inner Jacket LZSH - Flame Retardant Low Smoke Zero Halogen Compound EPR - equivalent EPR, LSZH. SHF2 - equivalent Siliconee Rubber, LSZH.</Text><Text id="18971" page="48">4) Inner Sheath (Moisture &amp; Chemical Barrier) LS - Lead Sheath MLS - Multi-Layer Sheath (AL/HDPE/PE)</Text><Text id="18972" page="48">5) Bedding LZSH - Flame Retardant Low Smoke Zero Halogen Compound</Text><Text id="18973" page="48">6) Armour GSWA - Galvanised Steel Wire Armour</Text><Text id="18974" page="48">7) Outer Jacket LZSH - Flame Retardant Low Smoke Zero Halogen Compound EPR - equivalent EPR, LSZH. SHF2 - equivalent Siliconee Rubber, LSZH.</Text><Text id="18975" page="48">8) Number of Cores or Pairs or Triads or Quads</Text><Text id="18976" page="48">2C, 3C, 4C, 7C, 11C, 19C, 27C, 37C, 1P, 1T, 1Q 2P, 2T, 2Q 10P, 10T, 10Q 20P, 20T</Text><Text id="18977" page="49">Outer jacket colour shall be as per application.</Text><Text id="18978" page="49">1.0 mm2, 1.5mm² or 2.5mm² or state the alternative size</Text><Text id="18979" page="49">Use the “ – “ (dash symbol) to indicate when the designation parameter is not applicable, as necessary for cables types without inner sheath and without bedding material.</Text><Text id="18980" page="50">THERMOCOUPLE EXTENSION CABLE FOR OUTDOOR ABOVE GROUND INSTALLATION</Text><Text id="18981" page="50">Thermocouple Extension cables - Low Smoke Zero Halogen Flame Retardant or Fire Resistant cable types, used for above ground outdoor installation shall be identified with the following designation:</Text><Text id="18982" page="50">1) Core Insulation XLPE - Flame retardant Cross (X) Linked Polyethylene MGT XLPE - Mica impregnated glass tape beneath extruded layer of XLPE EPR - Ethylene Propylene Rubber MGT EPR - Mica impregnated glass tape beneath extruded layer of EPR S95 - Cross linked Silicone Rubber with treated glass fibre braid MGT S95 - Mica impregnated glass tape beneath extruded layer of S95</Text><Text id="18983" page="50">2) Screen OS - Overall Screen IS &amp; OS - Individual and Overall Screen</Text><Text id="18984" page="50">3) Inner Jacket LZSH - Flame Retardant Low Smoke Zero Halogen Compound</Text><Text id="18985" page="50">4) Armour GSWA - Galvanised Steel Wire Armour</Text><Text id="18986" page="50">5) Outer Jacket LZSH - Flame Retardant Low Smoke Zero Halogen Compound</Text><Text id="18989" page="50">1.0 mm2, 1.5mm² or state the alternative size State the Thermocouple Type; Type B, E, J, K, N, R, S or Type T.</Text><Text id="18990" page="50">Use the “ – “ (dash symbol) to indicate when the designation parameter is not applicable, as necessary for cables types without inner jacket and/or without armour.</Text><Text id="18992" page="51">Thermocouple Extension cables - Low Smoke Zero Halogen Flame Retardant or Fire Resistant cable types, used for underground or outdoor installation shall be identified with the following designation;</Text><Text id="18993" page="51">LSZH 1 2 3 4 5 6 7 8 9</Text><Text id="18995" page="51">For example LSZH/MGT XLPE/IS &amp; OS/LZSH/MLS/LSZH/GSWA/LZSH/2P/1.5 mm²/Type K</Text><Text id="18996" page="51">1) Core Insulation XLPE - Flame retardant Cross (X) Linked Polyethylene MGT XLPE - Mica impregnated glass tape beneath extruded layer of XLPE EPR - Ethylene Propylene Rubber MGT EPR - Mica impregnated glass tape beneath extruded layer of EPR S95 - Cross linked Siliconee Rubber with treated glass fibre braid MGT S95 - Mica impregnated glass tape beneath extruded layer of S95</Text><Text id="18997" page="51">2) Screen OS - Overall Screen IS &amp; OS - Individual and Overall Screen</Text><Text id="18998" page="51">3) Inner Jacket LZSH - Flame Retardant Low Smoke Zero Halogen Compound EPR - equivalent EPR, LSZH. SHF2 - equivalent Siliconee Rubber, LSZH.</Text><Text id="18999" page="51">4) Inner Sheath (Moisture &amp; Chemical Barrier) LS - Lead Sheath MLS - Multi-Layer Sheath (AL/HDPE/PE)</Text><Text id="19000" page="51">5) Bedding LZSH - Flame Retardant Low Smoke Zero Halogen Compound</Text><Text id="19001" page="51">6) Armour GSWA - Galvanised Steel Wire Armour</Text><Text id="19002" page="51">7) Outer Jacket LZSH - Flame Retardant Low Smoke Zero Halogen Compound EPR - equivalent EPR, LSZH. SHF2 - equivalent Silicone Rubber, LSZH.</Text><Text id="19003" page="51">8) Number of Pairs 1P, 2P, 10P, 20P</Text><Text id="19004" page="51">9) CSA of each Conductor 1.0 mm2, 1.5mm² or 2.5mm² or state the alternative size</Text><Text id="19005" page="51">State the Thermocouple Type; Type B, E, J, K, N, R, S or Type T. Use the “ – “ (dash symbol) to indicate when the designation parameter is not applicable, as necessary for cables types without inner sheath and without bedding material.</Text><Text id="19007" page="52">Foundation Fieldbus cables - Low Smoke Zero Halogen Flame Retardant or Fire Resistant cable types, used for above ground outdoor installation shall be identified with the following designation:</Text><Text id="19009" page="52">1) Core Insulation XLPE - Flame retardant Cross (X) Linked Polyethylene MGT XLPE - Mica impregnated glass tape beneath extruded layer of XLPE EPR - Ethylene Propylene Rubber MGT EPR - Mica impregnated glass tape beneath extruded layer of EPR S95 - Cross linked Silicone Rubber with treated glass fibre braid MGT S95 - Mica impregnated glass tape beneath extruded layer of S95</Text><Text id="19010" page="52">2) Foil Screen OS - Overall Foil Screen IS &amp; OS - Individual Foil and Overall Foil Screen</Text><Text id="19011" page="52">Each foil screen is an aluminium tape plastic coated on one surface, with the metal surface in contact with a drain wire.</Text><Text id="19012" page="52">3) Inner Jacket LZSH - Flame Retardant Low Smoke Zero Halogen Compound BRAID - Tinned copper braid in continuous contact with a drain wire.</Text><Text id="19013" page="52">4) Armour GSWA - Galvanised Steel Wire Armour</Text><Text id="19014" page="52">5) Outer Jacket LZSH - Flame Retardant Low Smoke Zero Halogen Compound</Text><Text id="19015" page="52">6) Number of Cores or Pairs 1P, 2P, 5P, 10P, 20P</Text><Text id="19016" page="52">7) CSA of each Conductor 1.0mm², 1.5 mm2 or state the alternative size.</Text><Text id="19017" page="52">Outer jacket colour shall be as per application.</Text><Text id="19018" page="52">Use the “ – “ (dash symbol) to indicate when the designation parameter is not applicable, as necessary for cables types without inner jacket and/or without armour.</Text><Text id="19020" page="53">Foundation Fieldbus cables - Low Smoke Zero Halogen Flame Retardant or Fire Resistant cable types, used for underground or outdoor installation shall be identified with the following designation:</Text><Text id="19021" page="53">1) Core Insulation XLPE - Flame retardant Cross (X) Linked Polyethylene MGT XLPE - Mica impregnated glass tape beneath extruded layer of XLPE EPR - Ethylene Propylene Rubber MGT EPR - Mica impregnated glass tape beneath extruded layer of EPR S95 - Cross linked Silicone Rubber with treated glass fibre braid MGT S95 - Mica impregnated glass tape beneath extruded layer of S95</Text><Text id="19022" page="53">2) Screen OS - Overall Foil Screen IS &amp; OS - Individual Foil and Overall Foil Screen Each foil screen is an aluminium tape plastic coated on one surface, with the metal surface in contact with a drain wire.</Text><Text id="19023" page="53">3) Inner Jacket LZSH - Flame Retardant Low Smoke Zero Halogen Compound BRAID - Tinned copper braid in continuous contact with a drain wire.</Text><Text id="19024" page="53">4) Inner Sheath (Moisture &amp; Chemical Barrier) LS - Lead Sheath MLS - Multi-Layer Sheath (AL/HDPE/PE)</Text><Text id="19025" page="53">5) Bedding LZSH - Flame Retardant Low Smoke Zero Halogen Compound</Text><Text id="19026" page="53">6) Armour GSWA - Galvanised Steel Wire Armour.</Text><Text id="19027" page="53">7) Outer Jacket LZSH - Flame Retardant Low Smoke Zero Halogen Compound EPR - equivalent EPR, LSZH. SHF2 - equivalent Silicone Rubber, LSZH.</Text><Text id="19028" page="53">8) Number of Cores or Pairs 1P, 2P, 10P, 20P</Text><Text id="19029" page="53">9) CSA of each Conductor 1.0mm² , 1.5 mm2 or state the alternative size.</Text><Text id="19030" page="53">Outer jacket colour shall be as per application. Use the “ – “ (dash symbol) to indicate when the designation parameter is not applicable, as necessary for cables types without inner sheath and without bedding material.</Text><Text id="19031" page="54">FIRE RESISTANT CABLE FOR OUTDOOR ABOVE GROUND INSTALLATION</Text><Text id="19032" page="54">Control cables - Low Smoke Zero Halogen Flame Retardant or Fire Resistant cable types, used for above ground outdoor installation shall be identified with the following designation:</Text><Text id="19034" page="54">1) Core Insulation XLPE - Flame retardant Cross (X) Linked Polyethylene MGT XLPE - Mica impregnated glass tape beneath extruded layer of XLPE EPR - Ethylene Propylene Rubber MGT EPR - Mica impregnated glass tape beneath extruded layer of EPR S95 - Cross linked Silicone Rubber with treated glass fibre braid MGT S95 - Mica impregnated glass tape beneath extruded layer of S95</Text><Text id="19035" page="54">Cores should be laid up with extruded Flame Retardant LSZH Compound filler for up to 5 cores. For 6 cores or more a wrapping of polyester tape is required.</Text><Text id="19036" page="54">2) Screen OS - Overall Screen IS &amp; OS - Individual and Overall Screen</Text><Text id="19037" page="54">3) Inner Jacket LZSH - Flame Retardant Low Smoke Zero Halogen Compound</Text><Text id="19038" page="54">4) Armour GSWA - Galvanised Steel Wire Armour</Text><Text id="19039" page="54">5) Outer Jacket LZSH - Flame Retardant Low Smoke Zero Halogen Compound</Text><Text id="19040" page="54">6) Number of Cores 2C, 3C, 4C, 7C, 11C, 19C, 27C, 37C</Text><Text id="19041" page="54">7) CSA of each Conductor 2.5mm² minimum or state the alternative size.</Text><Text id="19042" page="54">Outer jacket colour shall be as per application.</Text><Text id="19043" page="54">Use the “ – “ (dash symbol) to indicate when the designation parameter is not applicable, as necessary for cables types without inner jacket and/or without armour.</Text><Text id="19045" page="55">Control cables - Low Smoke Zero Halogen Flame Retardant or Fire Resistant cable types, used for underground outdoor installation shall be identified with the following designation:</Text><Text id="19046" page="55">LSZH 1 2 3 4 5 6 7 8 9</Text><Text id="19047" page="55">Colour for example LSZH/MGT XLPE/IS &amp; OS/LZSH/MLS/LSZH/GSWA/LZSH/7C/2.5 mm²/Black</Text><Text id="19048" page="55">1) Core Insulation XLPE - Flame retardant Cross (X) Linked Polyethylene MGT XLPE - Mica impregnated glass tape beneath extruded layer of XLPE EPR - Ethylene Propylene Rubber MGT EPR - Mica impregnated glass tape beneath extruded layer of EPR S95 - Cross linked Silicone Rubber with treated glass fibre braid MGT S95 - Mica impregnated glass tape beneath extruded layer of S95</Text><Text id="19049" page="55">Cores should be laid up with extruded Flame Retardant LSZH Compound filler for up to 5 cores. For 6 cores or more a wrapping of polyester tape is required.</Text><Text id="19050" page="55">2) Screen OS - Overall Screen IS &amp; OS - Individual and Overall Screen</Text><Text id="19051" page="55">3) Inner Jacket LZSH - Flame Retardant Low Smoke Zero Halogen Compound</Text><Text id="19052" page="55">4) Inner Sheath (Moisture &amp; Chemical Barrier) LS - Lead Sheath MLS - Multi-Layer Sheath (AL/HDPE/PE)</Text><Text id="19053" page="55">5) Bedding LZSH - Flame Retardant Low Smoke Zero Halogen Compound</Text><Text id="19054" page="55">6) Armour GSWA - Galvanised Steel Wire Armour.</Text><Text id="19055" page="55">7) Outer Jacket LZSH - Flame Retardant Low Smoke Zero Halogen Compound EPR - equivalent EPR, LSZH. SHF2 - equivalent Silicone Rubber, LSZH.</Text><Text id="19056" page="55">8) Number of Cores 2C, 3C, 4C, 7C, 11C, 19C, 27C, 37C</Text><Text id="19057" page="55">9) CSA of each Conductor 2.5mm² minimum or state the alternative size.</Text><Text id="19058" page="55">Outer jacket colour shall be as per application. Use the “ – “ (dash symbol) to indicate when the designation parameter is not applicable, as necessary for cables types without inner jacket and/or without armour.</Text><Text id="19059" page="56">FIBRE OPTIC CABLE FOR OUTDOOR ABOVE GROUND INSTALLATION Fibre Optic cables:</Text><Text id="19060" page="56">LSZH 1 2 3 4 5 6 7 8 Colour for example LSZH/SMF OS2/PBT 6/Tape/AT/LSZH1/GSWA/LZSH/24//Black</Text><Text id="19061" page="56">1) Fibre Type and Glass Fibre Grade Code SMF- Single mode glass fibres OM3- Grade 3, 50/125µm mutli-mode MMF- Multi-mode glass fibres OM4- Grade 4, 50/125µm mutli-mode OM1- Grade 1, 62.5/125µm mutli-mode OS2- Grade S, single-mode OM2- Grade 2, 50/125µm mutli-mode</Text><Text id="19062" page="56">2) Buffer Tubes and quantity of fibres per tube PBT - PolyButylene Terephthalate HF - Halar Fluoroplastic Other - equivalent to PBT or HF materials</Text><Text id="19063" page="56">Minimum 6 fibres per buffer tube. Each extruded buffer tube with a moisture resistant gel filling</Text><Text id="19064" page="56">compound. Multiple buffer tubes are to be twisted around a dielectric material rod provided for central strength together with a filler core where required, flame retardant, LSZH.</Text><Text id="19065" page="56">3) Separator / Inner Sheath Foil - Aramid yarn for strength and aluminium foil core wrapping or separator Tape - Water blocking E-glass yarn and polyester tape together with Aramid strength members and a Rip cord. LSZH - Flame Retardant Low Smoke Zero Halogen Compound sheath.</Text><Text id="19066" page="56">4) Armour Tape AT - Aluminium Tape armour and a Rip cord PT - Polyester Tape armour and a Rip cord CST - Corrugated Steel Tape armour and a Rip cord</Text><Text id="19067" page="56">5) Inner Jacket LZSH1 - Flame Retardant Low Smoke Zero Halogen Compound LSZH2 - Flame Retardant LSZH Compound together with Aramid strength members and a</Text><Text id="19069" page="56">6) Armour GSWA - Galvanised Steel Wire Armour. CST - Corrugated Steel Tape armour and a Rip cord.</Text><Text id="19070" page="56">7) Outer Jacket LZSH - Flame Retardant Low Smoke Zero Halogen Compound EPR - equivalent EPR, LSZH. SHF2 - equivalent Silicone Rubber, LSZH.</Text><Text id="19071" page="57">8) Number of Fibres (total) 6, 12, 24, 36, 48, 72, 96, 144</Text><Text id="19072" page="57">Outer jacket colour shall be as per application. Fibres and Buffer Tubes shall be colour coded in accordance with EIA/TIA-598.</Text><Text id="19073" page="57">A printed legend shall be provided on the outer jacket of the FO cable at equal distances to identify the quantity and types of glass fibres within the cable.</Text><Text id="19074" page="57">Use the “ – “ (dash symbol) to indicate when the designation parameter is not applicable, as necessary for cables types without inner jacket and/or without armour.</Text><Text id="19075" page="58">APPENDIX 3 CONSTRUCTION DETAILS FOR EACH CABLE TYPE</Text><Text id="19076" page="58">(A1) Single pair, collective screen, unarmoured, flame retardant. (XLPE/Coll Scr/ LSHF) Voltage Rating: 300/500V</Text><Text id="19079" page="58">1. Conductors Standed annealed copper. Circular section, Class 2 according to IEC 60228. Temperature rating 90°C. Size: 1.5 mm 2 min for analogue &amp; digital signals.</Text><Text id="19080" page="58">2.5 mm 2 for Solenoids, beacons, hooters Identification Black and White.</Text><Text id="19081" page="58">2. Insulation Flame retardant material as per data sheet.</Text><Text id="19084" page="58">3. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19085" page="58">4. Cable screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19086" page="58">5. Inner jacket Flame retardant Low Smoke Zero Halogen Compound. Colour: Black.</Text><Text id="19087" page="58">6. Outer jacket Flame retardant Low Smoke Zero Halogen compound.</Text><Text id="19088" page="58">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’.</Text><Text id="19089" page="58">Note: This cable type shall be only utilized for indoor application where the cable is installed and fully routed within the same building.</Text><Text id="19090" page="59">(A2) Multi-pair, Collective Screen, unarmoured, flame retardant. (XLPE/Coll Scr /LSHF) Voltage Rating: 300/500V</Text><Text id="19093" page="59">1. Conductors Standed annealed copper. Circular section, Class 2 according to IEC 60228. Temperature rating 90°C. Size: 1.0 mm2 min for analogue &amp; digital signals.</Text><Text id="19095" page="59">Identification Black and White. Each core printed with pair number throughout the cable at equal distances.</Text><Text id="19096" page="59">2. Insulation Flame retardant material as per data sheet.</Text><Text id="19099" page="59">3. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19100" page="59">4. Cable screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19101" page="59">5. Inner jacket Flame retardant Low Smoke Zero Halogen Compound , LSZH. Colour: Black.</Text><Text id="19102" page="59">6. Outer jacket Flame retardant Low Smoke Zero Halogen compound.</Text><Text id="19103" page="59">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’.</Text><Text id="19104" page="59">Note: This cable type shall be only utilized for indoor application where the cable is installed and fully routed within the same building.</Text><Text id="19105" page="60">(A3) Single-triad, collective screen, unarmoured, flame retardant. (XLPE/Coll Scr/LSHF) Voltage Rating: 300/500V</Text><Text id="19108" page="60">1. Conductors Stranded annealed copper. Circular section, Class 2 according to IEC 60228. Temperature rating 90°C. Size: 1.5 mm 2 min for RTD, Winding Temperature &amp; Vibration signals.</Text><Text id="19110" page="60">2. Insulation Flame retardant material as per data sheet. CABLE:</Text><Text id="19112" page="60">3. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19113" page="60">4. Cable screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19114" page="60">5. Outer jacket Flame retardant Low Smoke Zero Halogen Compound.</Text><Text id="19115" page="60">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’.</Text><Text id="19116" page="60">Note: For the cables utilized for Vibration Signals Total capacitance of (core to core) + (core to screen) shall be less than 200nf/km.2.</Text><Text id="19117" page="60">Note: This cable type shall be only utilized for indoor application where the cable is installed and fully routed within the same building.</Text><Text id="19118" page="61">(A4) Multi- triad, individual &amp; collective screen, unarmoured, flame retardant. (XLPE/Ind &amp; Coll Scr/LSHF) Voltage Rating: 300/500V</Text><Text id="19121" page="61">1. Conductor s Stranded annealed copper. Circular section, Class 2 according to IEC 60228. Temperature rating 90°C.</Text><Text id="19123" page="61">Identification Black, Red &amp; White. Each core printed with triad number through out the cable at equal distances.</Text><Text id="19124" page="61">2. Insulation Flame retardant material as per data sheet. CABLE:</Text><Text id="19125" page="61">Cores are twisted into triads – each triad covered with:</Text><Text id="19126" page="61">3. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19127" page="61">4. Ind screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap.</Text><Text id="19128" page="61">Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19129" page="61">5. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19130" page="61">6. Coll screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19131" page="61">7. Outer jacket Flame retardant Low Smoke Zero Halogen Compound. Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’.</Text><Text id="19132" page="61">Note: For the cables utilized for Vibration Signals Total capacitance of (core to core) + (core to screen) shall be less than 200nf/km.2. Note: This cable type shall be only utilized for indoor application where the cable is installed and fully routed within the same building.</Text><Text id="19133" page="62">(A5) Single-pair, collective screen, armoured, flame retardant. (XLPE/Coll Scr/SWA/LSHF) Voltage Rating: 300/500V</Text><Text id="19136" page="62">1. Conductors Stranded annealed copper. Circular section, Class 2 according to IEC 60228. Temperature rating 90°C. Size: 1.5 mm² min for analogue &amp; digital signals. 2.5 mm 2 for Solenoids, beacons, hooters Identification Black and White.</Text><Text id="19137" page="62">2. Insulation Flame retardant material as per data sheet.</Text><Text id="19140" page="62">3. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19141" page="62">4. Cable screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape.</Text><Text id="19142" page="62">Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19143" page="62">5. Inner jacket Flame retardant Low Smoke Zero Halogen Compound, LSZH. Colour: Black.</Text><Text id="19145" page="62">7. Outer jacket Flame retardant Low Smoke Zero Halogen Compound. Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’.</Text><Text id="19146" page="63">(A6) Multi-pair, individual &amp; collective screen, armoured, flame retardant. (XLPE/Ind &amp; Coll Scr/SWA/LSHF) Voltage Rating: 300/500V</Text><Text id="19147" page="63">1 2 3 4 5 6 7 8</Text><Text id="19149" page="63">1. Conductors Stranded annealed copper. Circular section, Class 2 according to IEC 60228. Temperature rating 90°C. Size: 1.0 mm2 min for analogue &amp; digital signals.</Text><Text id="19150" page="63">Identification Black and White. Each core printed with pair number throughout the cable at equal distances.</Text><Text id="19151" page="63">2. Insulation Flame retardant material as per data sheet.</Text><Text id="19152" page="63">CABLE: Cores are twisted together and covered with:</Text><Text id="19153" page="63">3. Ind screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19155" page="63">5. Coll screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19156" page="63">6. Inner jacket Flame retardant Low Smoke Zero Halogen Compound, LSZH. Colour: Black.</Text><Text id="19158" page="63">8. Outer jacket Flame retardant Low Smoke Zero Halogen Compound.</Text><Text id="19159" page="63">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’.</Text><Text id="19160" page="64">(A7) Multi-pair, collective screen, armoured, flame retardant. (XLPE/ Coll Scr/ SWA/LSHF) Voltage Rating: 300/500V</Text><Text id="19163" page="64">1. Conductors Stranded annealed copper. Circular section, Class 2 according to IEC 60228. Temperature rating 90°C. Size: As per data sheet for Digital (24VDC or Namur) signals.</Text><Text id="19165" page="64">Identification Black and White. Each core printed with pair number throughout the cable at equal distances.</Text><Text id="19166" page="64">2. Insulation Flame retardant material as per data sheet .</Text><Text id="19170" page="64">4. Coll screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19171" page="64">5. Inner jacket Flame retardant Low Smoke Zero Halogen Compound , LSZH. Colour: Black.</Text><Text id="19173" page="64">7. Outer jacket Flame retardant Low Smoke Zero Halogen Compound.</Text><Text id="19174" page="64">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’.</Text><Text id="19175" page="65">(A8) Single-triad, collective screen, armoured, flame retardant. (XLPE/Coll Scr/ SWA/LSHF) Voltage Rating: 300/500V</Text><Text id="19178" page="65">1. Conductors Stranded annealed copper. Circular section, Class 2 according to IEC 60228. Temperature rating 90°C. Size: 1.5 mm 2 min for RTD, Winding Temperature &amp; Vibration signals.</Text><Text id="19180" page="65">2. Insulation Flame retardant material as per data sheet. CABLE:</Text><Text id="19182" page="65">3. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19183" page="65">4. Cable screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19184" page="65">5. Inner jacket Flame retardant Low Smoke Zero Halogen Compound. Colour: Black</Text><Text id="19186" page="65">7. Outer jacket Flame retardant Low Smoke Zero Halogen Compound.</Text><Text id="19187" page="65">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’.</Text><Text id="19188" page="65">Note: For the cables utilized for Vibration Signals Total capacitance of (core to core)2 + (core to screen) shall be less than 200nf/km.2.</Text><Text id="19189" page="66">(A9) Multi- triad, individual &amp; collective screen, armoured, flame retardant. (XLPE/Ind &amp; Coll Scr/ SWA/LSHF) Voltage Rating: 300/500V</Text><Text id="19190" page="66">1 2 3 4 5 6 7 8</Text><Text id="19192" page="66">1. Conductor s Stranded annealed copper. Circular section, Class 2 according to IEC 60228. Temperature rating 90°C.</Text><Text id="19193" page="66">Size: As per data sheet for Winding Temperature &amp; Vibration Instrument signals.</Text><Text id="19194" page="66">Identification Black, Red &amp; White. Each core printed with triad number through out the cable at equal distances.</Text><Text id="19195" page="66">2. Insulation Flame retardant material as per data sheet . CABLE:</Text><Text id="19197" page="66">3. Ind screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap.</Text><Text id="19198" page="66">Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19200" page="66">5. Coll screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19201" page="66">6. Inner jacket Flame retardant Low Smoke Zero Halogen Compound. Colour: Black.</Text><Text id="19203" page="66">8. Outer jacket Flame retardant Low Smoke Zero Halogen Compound.</Text><Text id="19204" page="66">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’.</Text><Text id="19205" page="67">(A10) Single-pair, collective screen, armoured, external buried, flame retardant. (XLPE/Coll Scr/LS/SWA/LSHF) Voltage Rating: 300/500V</Text><Text id="19206" page="67">1 2 3 4 5 6 7 8 9</Text><Text id="19208" page="67">1. Conductors Stranded annealed copper. Circular section, Class 2 according to IEC 60228. Temperature rating 90°C. Size: 1.5 mm² min for analogue &amp; digital signals. 2.5 mm 2 for Solenoids, beacons, hooters</Text><Text id="19210" page="67">2. Insulation Flame retardant material as per data sheet.</Text><Text id="19211" page="67">CABLE: Cores are twisted together and covered with:</Text><Text id="19212" page="67">3. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19213" page="67">4. Cable screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19214" page="67">5. Inner jacket Flame retardant Low Smoke Zero Halogen Compound , LSZH. Colour: Black.</Text><Text id="19215" page="67">6. Inner Sheath Lead Sheath (or Lead pipe). A multi-layered Inner Sheath (AL/HDPE/PA instead of lead sheath) will be considered if the multi-layer sheath provides the same protection as a lead sheath for hydrocarbons, chemical and solvents, saline water ingress and vermin protection, as per BS 50288-7 section 4.18.2.</Text><Text id="19216" page="67">7. Bedding Flame retardant Low Smoke Zero Halogen Compound , LSZH. Colour: Black.</Text><Text id="19218" page="67">9. Outer jacket Flame retardant Low Smoke Zero Halogen Compound.</Text><Text id="19219" page="67">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’.</Text><Text id="19220" page="68">1 2 3 4 5 6 7 8 9 10 11</Text><Text id="19222" page="68">1. Conductors Stranded annealed copper. Circular section, Class 2 according to IEC 60228. Temperature rating 90°C. Size: 1.0 mm2 for analogue &amp; digital signals.</Text><Text id="19224" page="68">Each core printed with pair number throughout the cable at equal distances.</Text><Text id="19225" page="68">2. Insulation Flame retardant material as per data sheet. Cores are twisted into pairs – each pair covered with:</Text><Text id="19226" page="68">3. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19227" page="68">4. Ind screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19228" page="68">CABLE: Pairs are twisted into multi-pairs - Pairs twisted (10 to 14 twists/m) together are covered with:</Text><Text id="19229" page="68">5. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19230" page="68">6. Coll screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19231" page="68">7. Inner jacket Flame retardant Low Smoke Zero Halogen Compound ,LSZH. Colour: Black.</Text><Text id="19232" page="68">8. Inner Sheath Lead Sheath (or Lead pipe). A multi-layered Inner Sheath (AL/HDPE/PA instead of lead sheath) will be considered if the multi-layer sheath provides the same protection as a lead sheath for hydrocarbons, chemical and solvents, saline water ingress and vermin protection, as per BS 50288-7 section 4.18.2.</Text><Text id="19233" page="68">9. Bedding Flame retardant Low Smoke Zero Halogen Compound.</Text><Text id="19236" page="68">11. Outer jacket Flame retardant Low Smoke Zero Halogen Compound.</Text><Text id="19237" page="68">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’.</Text><Text id="19238" page="69">1 2 3 4 5 6 7 8 9</Text><Text id="19240" page="69">1. Conductors Stranded annealed copper. Circular section, Class 2 according to IEC 60228. Temperature rating 90°C. Size: 1.5 mm² min for analogue &amp; digital signals.</Text><Text id="19242" page="69">2. Insulation Flame retardant material as per data sheet.</Text><Text id="19243" page="69">CABLE: Cores are twisted together and covered with:</Text><Text id="19244" page="69">3. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19245" page="69">4. Cable screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19246" page="69">5. Inner jacket Flame retardant Low Smoke Zero Halogen Compound , LSZH. Colour: Black.</Text><Text id="19247" page="69">6. Inner Sheath Lead Sheath (or Lead pipe). A multi-layered Inner Sheath (AL/HDPE/PA instead of lead sheath) will be considered if the multi-layer sheath provides the same protection as a lead sheath for hydrocarbons, chemical and solvents, saline water ingress and vermin protection, as per BS 50288-7 section 4.18.2.</Text><Text id="19248" page="69">7. Bedding Flame retardant Low Smoke Zero Halogen Compound. Colour: Black.</Text><Text id="19250" page="69">9. Outer jacket Flame retardant Low Smoke Zero Halogen Compound.</Text><Text id="19251" page="69">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’ and Fire Resistant to IEC 60331.</Text><Text id="19252" page="70">(A13) Multi-triad, individual &amp; collective screen, armoured, external buried, flame retardant. (XLPE/Ind &amp; Coll Scr/LS/SWA/LSHF) Voltage Rating: 300/500V</Text><Text id="19253" page="70">1 2 3 4 5 6 7 8 9 10 11</Text><Text id="19255" page="70">1. Conductor s Stranded annealed copper. Circular section, Class 2 according to IEC 60228. Temperature rating 90°C.</Text><Text id="19256" page="70">Size: As per data sheet for Winding Temperature &amp; Vibration Instrument signals. Identification Black, Red &amp; White.</Text><Text id="19257" page="70">Each core printed with triad number through out the cable at equal distances.</Text><Text id="19258" page="70">2. Insulation Flame retardant material as per data sheet. Cores are twisted into triads – each triad covered with:</Text><Text id="19259" page="70">3. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19260" page="70">4. Ind screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap.</Text><Text id="19261" page="70">Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19262" page="70">CABLE: Triads twisted into multi-triads - Triads twisted (10 to 14 twists/m) together are covered with:</Text><Text id="19263" page="70">5. Fillers Flame retardant moisture resistant material, LSZH.</Text><Text id="19264" page="70">6. Coll screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19265" page="70">7. Inner jacket Flame retardant Low Smoke Zero Halogen Compound. Colour: Black.</Text><Text id="19266" page="70">8. Inner Sheath Lead Sheath (or Lead pipe). A multi-layered Inner Sheath (AL/HDPE/PA instead of lead sheath) will be considered if the multi-layer sheath provides the same protection as a lead sheath for hydrocarbons, chemical and solvents, saline water ingress and vermin protection, as per BS 50288-7 section 4.18.2.</Text><Text id="19267" page="70">9. Bedding Flame retardant Low Smoke Zero Halogen Compound.</Text><Text id="19270" page="70">11. Outer jacket Flame retardant Low Smoke Zero Halogen Compound.</Text><Text id="19271" page="71">(B1) Single pair, collective screen, unarmoured, fire resistant. (Mica/XLPE/Coll Scr/ LSHF) Voltage Rating: 300/500V</Text><Text id="19274" page="71">1. Conductors Standed annealed copper. Circular section, Class 2 according to IEC 60228. Temperature rating 90°C. Size: 1.5 mm 2 min for Analogue or Digital signals (inside building) and ESD, F&amp;G and PA applications. 2.5 mm 2 for Solenoids, beacons, hooters</Text><Text id="19276" page="71">2. Insulation Mica impregnated glass tape beneath extruded layer of flame retardant cross linked Polyethylene (XLPE) or equivalent Ethylene Propylene Rubber (EPR) or equivalent Silicone Rubber (S95) or material as per data sheet.</Text><Text id="19280" page="71">4. Cable screen One tinned copper 0.50 mm min solid drain wire and aluminium backed (overall) Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19281" page="71">5. Inner jacket Flame retardant Low Smoke Zero Halogen Compound. Colour: Black.</Text><Text id="19282" page="71">6. Outer jacket Flame retardant Low Smoke Zero Halogen compound</Text><Text id="19283" page="71">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’ and Fire Resistant to IEC 60331.</Text><Text id="19284" page="71">Note: This cable type shall be only utilized for indoor application where the cable is installed and fully routed within the same building.</Text><Text id="19285" page="72">(B2) Multi-pair, Collective Screen, unarmoured, fire resistant. (Mica/XLPE/Coll Scr /LSHF) Voltage Rating: 300/500V</Text><Text id="19288" page="72">1. Conductors Standed annealed copper. Circular section, Class 2 according to IEC 60228. Temperature rating 90°C. Size: 1.0 mm2 for Analogue or Digital signals (inside building) and ESD, F&amp;G and PA applications. 2.5 mm 2 for Solenoids, beacons, hooters</Text><Text id="19289" page="72">Identification Black and White. Each core printed with pair number throughout the cable at equal distances.</Text><Text id="19290" page="72">2. Insulation Mica impregnated glass tape beneath extruded layer of flame retardant cross</Text><Text id="19291" page="72">linked Polyethylene (XLPE) or equivalent Ethylene Propylene Rubber (EPR) or equivalent Silicone Rubber (S95) or material as per data sheet.</Text><Text id="19292" page="72">CABLE: Cores are twisted into pairs - Pairs twisted (10 to 14 twists/m) together are covered with:</Text><Text id="19294" page="72">4. Cable Screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19295" page="72">5. Inner jacket Flame retardant Low Smoke Zero Halogen Compound.</Text><Text id="19297" page="72">6. Outer jacket Flame retardant Low Smoke Zero Halogen Compound.</Text><Text id="19298" page="72">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’ and Fire Resistant to IEC 60331.</Text><Text id="19299" page="72">Note: This cable type shall be only utilized for indoor application where the cable is installed and fully routed within the same building.</Text><Text id="19300" page="73">(B3) Single-triad, collective screen, non-armoured, fire resistant. (XLPE/Coll Scr/LSHF) Voltage Rating: 300/500V</Text><Text id="19303" page="73">1. Conductors Stranded annealed copper. Circular section, Class 2 according to IEC 60228. Temperature rating 90°C. Size: 1.5 mm 2 for RTD, Vibration signals etc for ESD and FGS applications.</Text><Text id="19305" page="73">2. Insulation Mica impregnated glass tape beneath extruded layer of flame retardant cross</Text><Text id="19306" page="73">linked Polyethylene (XLPE) or equivalent Ethylene Propylene Rubber (EPR) or equivalent Silicone Rubber (S95) or material as per data sheet.</Text><Text id="19310" page="73">4. Cable screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19311" page="73">5. Outer jacket Flame retardant Low Smoke Zero Halogen compound.</Text><Text id="19312" page="73">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’ and Fire Resistant to IEC 60331.</Text><Text id="19313" page="73">Note: For the cables utilized for Vibration Signals Total capacitance of (core to core) + (core to screen) shall be less than 200nf/km.2.</Text><Text id="19314" page="73">Note: This cable type shall be only utilized for indoor application where the cable is installed and fully routed within the same building.</Text><Text id="19315" page="74">(B4) Multi- triad, individual &amp; collective screen, unarmoured, fire resistant. (Mica/XLPE/Ind &amp; Coll Scr/LSHF) Voltage Rating: 300/500V</Text><Text id="19318" page="74">1. Conductor s Stranded annealed copper. Circular section, Class 2 according to IEC 60228. Temperature rating 90°C.</Text><Text id="19319" page="74">Size: As per data sheet for RTD, F&amp;G Detector &amp; Vibration Signals etc for ESD, F&amp;G and PA applications.</Text><Text id="19320" page="74">Identification Black, Red &amp; White. Each core printed with triad number through out the cable at equal distances.</Text><Text id="19321" page="74">2. Insulation Mica impregnated glass tape beneath extruded layer of flame retardant cross</Text><Text id="19322" page="74">linked Polyethylene (XLPE) or equivalent Ethylene Propylene Rubber (EPR) or equivalent Silicone Rubber (S95) or material as per data sheet.</Text><Text id="19323" page="74">Cores are twisted into triads – each triad covered with:</Text><Text id="19324" page="74">3. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19325" page="74">4. Ind screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap.</Text><Text id="19326" page="74">Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19327" page="74">CABLE: Cores are twisted into triads - Triads twisted (10 to 14 twists/m) together are covered with:</Text><Text id="19328" page="74">5. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19329" page="74">6. Coll screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape.</Text><Text id="19330" page="74">Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19331" page="74">7. Outer jacket Flame retardant Low Smoke Zero Halogen compound.</Text><Text id="19332" page="74">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’ and Fire Resistant to IEC 60331.</Text><Text id="19337" page="75">1. Conductors Standed annealed copper. Circular section, Class 2 according to IEC 60228. Temperature rating 90°C Size 1.5 mm 2 min for Analogue and Digital signals and ESD, F&amp;G and PA applications. 2.5 mm 2 for Solenoids, beacons, hooters</Text><Text id="19339" page="75">2. Insulation Mica impregnated glass tape beneath extruded layer of flame retardant cross linked polyethylene (XLPE) or equivalent Ethylene Propylene Rubber (EPR) or equivalent Silicone Rubber (S95) or material as per data sheet.</Text><Text id="19342" page="75">3. Binder tape : PETP tape 50% overlap.</Text><Text id="19343" page="75">4. Cable screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19344" page="75">5. Inner jacket Flame retardant Low Smoke Zero Halogen compound , or equivalent EPR or equivalent S95 Rubber, LSZH. Colour: Black.</Text><Text id="19346" page="75">7. Outer jacket Flame retardant Low Smoke Zero Halogen compound</Text><Text id="19347" page="75">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’ and Fire Resistant to IEC 60331.</Text><Text id="19348" page="76">(B6) Multi-pair, individual &amp; collective screen, armoured, fire resistant. (Mica/XLPE/Ind &amp; Coll Scr/SWA/LSHF) Voltage Rating: 300/500V</Text><Text id="19349" page="76">1 2 3 4 5 6 7 8</Text><Text id="19351" page="76">1. Conductors Stranded annealed copper. Circular section, Class 2 according to IEC 60228. Temperature rating 90°C. Size: As per data sheet for Analogue signals for ESD, F&amp;G and PA applications.</Text><Text id="19352" page="76">Identification Black and White. Each core printed with pair number throughout the cable at equal distances.</Text><Text id="19353" page="76">2. Insulation Mica impregnated glass tape beneath extruded layer of flame retardant cross linked polyethylene (XLPE) or equivalent Ethylene Propylene Rubber (EPR) or equivalent Silicone Rubber (S95) or material as per data sheet.</Text><Text id="19354" page="76">CABLE: Cores are twisted together and covered with:</Text><Text id="19355" page="76">3. Ind screen One tinned copper 0.50 mm² min drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap.</Text><Text id="19356" page="76">Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19357" page="76">4. Insulating Tapes Glass - Silk and polyester.</Text><Text id="19358" page="76">5. Coll screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19359" page="76">6. Inner jacket Flame retardant Low Smoke Zero Halogen compound. Colour: Black</Text><Text id="19361" page="76">8. Outer jacket Flame retardant Low Smoke Zero Halogen compound</Text><Text id="19362" page="76">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’ and Fire Resistant to IEC 60331.</Text><Text id="19363" page="77">(B7) Multi-pair, collective screen, armoured, fire resistant. (Mica/XLPE/Coll Scr/SWA/LSHF) Voltage Rating: 300/500V</Text><Text id="19366" page="77">1. Conductors Stranded annealed copper. Circular section, Class 2 according to IEC 60228. Temperature rating 90°C. Size: 1.0 mm2 for Analogue and Digital I/O of ESD, F&amp;G and PA applications. 2.5 mm 2 for Solenoids, beacons, hooters</Text><Text id="19367" page="77">Identification Black and White. Each core printed with pair number throughout the cable at equal distances.</Text><Text id="19368" page="77">2. Insulation Mica impregnated glass tape beneath extruded layer of flame retardant cross</Text><Text id="19369" page="77">linked Polyethylene (XLPE) or equivalent Ethylene Propylene Rubber (EPR) or equivalent Silicone Rubber (S95) or material as per data sheet.</Text><Text id="19371" page="77">Cores are twisted into pairs - Pairs twisted (10 to 14 twists/m) together are covered with:</Text><Text id="19373" page="77">4. Cable screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed (overall) Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19374" page="77">5. Inner jacket Flame retardant Low Smoke Zero Halogen compound. Colour: Black</Text><Text id="19376" page="77">7. Outer jacket Flame retardant Low Smoke Zero Halogen compound.</Text><Text id="19377" page="77">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’ and Fire Resistant to IEC 60331</Text><Text id="19378" page="78">(B8) Single-triad, collective screen, armoured, fire resistant. (Mica/XLPE/Coll Scr/SWA/LSHF) Voltage Rating: 300/500V</Text><Text id="19381" page="78">1. Conductors Stranded annealed copper. Circular section, Class 2 according to IEC 60228. Temperature rating 90°C Size: 1.5 mm 2 min for RTD, F&amp;G Detector &amp; Vibration signals to ESD, F&amp;G and PA applications.</Text><Text id="19383" page="78">2. Insulation Mica impregnated glass tape beneath extruded layer of flame retardant cross</Text><Text id="19384" page="78">linked Polyethylene (XLPE) or equivalent Ethylene Propylene Rubber (EPR) or equivalent Silicone Rubber (S95) or material as per data sheet.</Text><Text id="19387" page="78">3. Binder tape : PETP tape 50% overlap.backed</Text><Text id="19388" page="78">4. Cable screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19389" page="78">5. Inner jacket Flame retardant Low Smoke Zero Halogen compound. Colour: Black</Text><Text id="19391" page="78">7. Outer jacket Flame Retardant Low Smoke Zero Halogen compound.</Text><Text id="19392" page="78">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’ and Fire Resistant to IEC 60331.</Text><Text id="19393" page="79">(B9) Multi- triad, individual &amp; collective screen, armoured, fire resistant. (Mica/XLPE/Ind &amp; Coll Scr/ SWA/LSHF) Voltage Rating: 300/500V</Text><Text id="19394" page="79">1 2 3 4 5 6 7 8</Text><Text id="19396" page="79">1. Conductor s Stranded annealed copper. Circular section, Class 2 according to IEC 60228. Temperature rating 90°C.</Text><Text id="19397" page="79">Size: As per data sheet for RTD, Winding Temperature, F&amp;G Detector &amp; Vibration signals and ESD, F&amp;G and PA applications.</Text><Text id="19398" page="79">Identification Black, Red &amp; White. Each core printed with triad number through out the cable at equal distances.</Text><Text id="19399" page="79">2. Insulation Mica impregnated glass tape beneath extruded layer of flame retardant cross</Text><Text id="19400" page="79">linked Polyethylene (XLPE) or equivalent Ethylene Propylene Rubber (EPR) or equivalent Silicone Rubber (S95) or material as per data sheet.</Text><Text id="19401" page="79">CABLE: Cores are twisted into triads - Triads twisted (10 to 14 twists/m) together are covered with:</Text><Text id="19402" page="79">3. Ind screen One tinned copper 0.50 mm² min drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap.</Text><Text id="19403" page="79">Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19404" page="79">4. Insulating Tape Glass - Silk and polyester.</Text><Text id="19405" page="79">5. Coll screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape.</Text><Text id="19406" page="79">Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19407" page="79">6. Inner jacket Flame retardant Low Smoke Zero Halogen Compound. Colour: Black.</Text><Text id="19409" page="79">8. Outer jacket Flame Retardant Low Smoke Zero Halogen compound</Text><Text id="19410" page="80">(B10) Single-pair, collective screen, armoured, external buried, fire resistant. (XLPE/Coll Scr/IS/SWA/LSHF) Voltage Rating: 300/500V</Text><Text id="19411" page="80">1 2 3 4 5 6 7 8 9</Text><Text id="19413" page="80">1. Conductors Stranded annealed copper. Circular section, Class 2 according to IEC 60228. Temperature rating 90°C. Size: 1.5 mm² min for analogue &amp; digital signals and ESD, F&amp;G and PA applications. 2.5 mm 2 for Solenoids, beacons, hooters</Text><Text id="19415" page="80">2. Insulation Mica impregnated glass tape beneath extruded layer of flame retardant cross linked Polyethylene (XLPE) or equivalent Ethylene Propylene Rubber (EPR) or equivalent Silicone Rubber (S95) or material as per data sheet.</Text><Text id="19418" page="80">3. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19419" page="80">4. Cable screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19420" page="80">5. Inner jacket Flame retardant Low Smoke Zero Halogen Compound Colour: Black.</Text><Text id="19421" page="80">6. Inner Sheath Lead Sheath (or Lead pipe). A multi-layered Inner Sheath (AL/HDPE/PA instead of lead sheath) will be considered if the multi-layer sheath provides the same protection as a lead sheath for hydrocarbons, chemical and solvents, saline water ingress and vermin protection, as per BS 50288-7 section 4.18.2.</Text><Text id="19422" page="80">7. Bedding Flame retardant Low Smoke Zero Halogen Compound ,LSZH. Colour: Black.</Text><Text id="19424" page="80">9. Outer jacket Flame Retardant Low Smoke Zero Halogen Compound.</Text><Text id="19425" page="81">(B11) Multi-pair, individual &amp; collective screen, armoured, external buried, fire resistant. (XLPE/Ind &amp; Coll Scr/IS/SWA/LSHF). Voltage Rating: 300/500V.</Text><Text id="19426" page="81">1 2 3 4 5 6 7 8 9 10 11</Text><Text id="19428" page="81">1. Conductors Stranded annealed copper. Circular section, Class 2 according to IEC 60228. Temperature rating 90°C. Size: As per data sheet for analogue &amp; digital signals and ESD, F&amp;G and PA applications.</Text><Text id="19429" page="81">Identification Black and White. Each core printed with pair number throughout the cable at equal distances.</Text><Text id="19430" page="81">2. Insulation Mica impregnated glass tape beneath extruded layer of flame retardant cross</Text><Text id="19431" page="81">linked Polyethylene (XLPE) or equivalent Ethylene Propylene Rubber (EPR) or equivalent Silicone Rubber (S95) or material as per data sheet. Cores are twisted into pairs – each pair covered with:</Text><Text id="19432" page="81">3. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19433" page="81">4. Ind screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19434" page="81">CABLE: Pairs are twisted into multi-pairs - Pairs twisted (10 to 14 twists/m) together are covered with:</Text><Text id="19435" page="81">5. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19436" page="81">6. Coll screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19437" page="81">7. Inner jacket Flame retardant Low Smoke Zero Halogen Compound. Colour: Black.</Text><Text id="19438" page="81">8. Inner Sheath Lead Sheath (or Lead pipe). A multi-layered Inner Sheath (AL/HDPE/PA instead of lead sheath) will be considered if the multi-layer sheath provides the same protection as a lead sheath for hydrocarbons, chemical and solvents, saline water ingress and vermin protection, as per BS 50288-7 section 4.18.2.</Text><Text id="19439" page="81">9. Bedding Flame retardant Low Smoke Zero Halogen Compound.</Text><Text id="19442" page="81">11. Outer jacket Flame Retardant Low Smoke Zero Halogen Compound</Text><Text id="19443" page="82">(B12) Single-triad, collective screen, armoured, external buried, fire resistant. (XLPE/Coll Scr/LS/SWA/LSHF) Voltage Rating: 300/500V</Text><Text id="19444" page="82">1 2 3 4 5 6 7 8 9</Text><Text id="19446" page="82">1. Conductors Stranded annealed copper. Circular section, Class 2 according to IEC 60228. Temperature rating 90°C. Size: 1.5 mm² min for RTD, F&amp;G Detectors wired to ESD, FGS.</Text><Text id="19448" page="82">2. Insulation Mica impregnated glass tape beneath extruded layer of flame retardant cross linked Polyethylene (XLPE) or equivalent Ethylene Propylene Rubber (EPR) or equivalent Silicone Rubber (S95) or material as per data sheet.</Text><Text id="19449" page="82">CABLE: Cores are twisted together and covered with:</Text><Text id="19450" page="82">3. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19451" page="82">4. Cable screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19452" page="82">5. Inner jacket Flame retardant Low Smoke Zero Halogen Compound Colour: Black.</Text><Text id="19453" page="82">6. Inner Sheath Lead Sheath (or Lead pipe). A multi-layered Inner Sheath (AL/HDPE/PA instead of lead sheath) will be considered if the multi-layer sheath provides the same protection as a lead sheath for hydrocarbons, chemical and solvents, saline water ingress and vermin protection, as per BS 50288-7 section 4.18.2.</Text><Text id="19454" page="82">7. Bedding Flame retardant Low Smoke Zero Halogen Compound.</Text><Text id="19457" page="82">9. Outer jacket Flame Retardant Low Smoke Zero Halogen Compound</Text><Text id="19458" page="82">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’ and Fire Resistant to IEC 60331.</Text><Text id="19459" page="83">(B13) Multi-triad, individual &amp; collective screen, armoured, external buried, fire resistant. (XLPE/Ind &amp; Coll Scr/LS/SWA/LSHF) Voltage Rating: 300/500V</Text><Text id="19460" page="83">1 2 3 4 5 6 7 8 9 10 11</Text><Text id="19462" page="83">1. Conductor s Stranded annealed copper. Circular section, Class 2 according to IEC 60228. Temperature rating 90°C.</Text><Text id="19463" page="83">Size: As per data sheet for RTD, Vibration Instrument signals to ESD, FGS. Identification Black, Red &amp; White.</Text><Text id="19464" page="83">Each core printed with triad number through out the cable at equal distances.</Text><Text id="19465" page="83">2. Insulation Mica impregnated glass tape beneath extruded layer of flame retardant cross</Text><Text id="19466" page="83">linked Polyethylene (XLPE) or equivalent Ethylene Propylene Rubber (EPR) or equivalent Silicone Rubber (S95) or material as per data sheet. Cores are twisted into triads – each triad covered with:</Text><Text id="19467" page="83">3. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19468" page="83">4. Ind screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap.</Text><Text id="19469" page="83">Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19470" page="83">CABLE: Triads twisted into multi-triads - Triads twisted (10 to 14 twists/m) together are covered with:</Text><Text id="19471" page="83">5. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19472" page="83">6. Coll screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19473" page="83">7. Inner jacket Flame retardant Low Smoke Zero Halogen Compound</Text><Text id="19475" page="83">8. Inner Sheath Lead Sheath (or Lead pipe). A multi-layered Inner Sheath (AL/HDPE/PA instead of lead sheath) will be considered if the multi-layer sheath provides the same protection as a lead sheath for hydrocarbons, chemical and solvents, saline water ingress and vermin protection, as per BS 50288-7 section 4.18.2.</Text><Text id="19476" page="83">9. Bedding Flame retardant Low Smoke Zero Halogen Compound ,LSZH.</Text><Text id="19479" page="83">11. Outer jacket Flame Retardant Low Smoke Zero Halogen Compound.</Text><Text id="19480" page="84">(B14) Multi-triad, collective screen, armoured, fire resistant. (XLPE/Coll Scr/SWA/LSHF) Voltage Rating: 300/500V</Text><Text id="19481" page="84">1 2 3 4 5 6 7 8</Text><Text id="19483" page="84">1. Conductor s Stranded annealed copper. Circular section, Class 2 according to IEC 60228. Temperature rating 90°C.</Text><Text id="19484" page="84">Size: As per data sheet for 3 wire Fire and Gas Detectors. Identification Black, Red &amp; White.</Text><Text id="19485" page="84">Each core printed with triad number through out the cable at equal distances.</Text><Text id="19486" page="84">2. Insulation Mica impregnated glass tape beneath extruded layer of flame retardant cross</Text><Text id="19487" page="84">linked Polyethylene (XLPE) or equivalent Ethylene Propylene Rubber (EPR) or equivalent Silicone Rubber (S95) or material as per data sheet.</Text><Text id="19488" page="84">Cores are twisted into triads – each triad covered with:</Text><Text id="19489" page="84">3. Fillers/Tape Flame retardant moisture resistant material , LSZH.</Text><Text id="19490" page="84">CABLE: Triads twisted into multi-triads - Triads twisted (10 to 14 twists/m) together are covered with:</Text><Text id="19491" page="84">4. Fillers/Tape Flame retardant moisture resistant material , LSZH.</Text><Text id="19492" page="84">5. Coll screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19493" page="84">6. Inner jacket Flame retardant Low Smoke Zero Halogen Compound Colour: Black.</Text><Text id="19495" page="84">8. Outer jacket Flame Retardant Low Smoke Zero Halogen Compound.</Text><Text id="19496" page="84">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’ and Fire Resistant to IEC 60331.</Text><Text id="19497" page="85">(B15) Multi-triad, collective screen, armoured, external buried, fire resistant. (XLPE/Coll Scr/LS/SWA/LSHF) Voltage Rating: 300/500V</Text><Text id="19498" page="85">1 2 3 4 5 6 7 8 9 10</Text><Text id="19500" page="85">1. Conductor s Stranded annealed copper. Circular section, Class 2 according to IEC 60228. Temperature rating 90°C.</Text><Text id="19501" page="85">Size: As per data sheet for 3 wire Fire and Gas Detectors. Identification Black, Red &amp; White.</Text><Text id="19502" page="85">Each core printed with triad number through out the cable at equal distances.</Text><Text id="19503" page="85">2. Insulation Mica impregnated glass tape beneath extruded layer of flame retardant cross</Text><Text id="19504" page="85">linked Polyethylene (XLPE) or equivalent Ethylene Propylene Rubber (EPR) or equivalent Silicone Rubber (S95) or material as per data sheet. Cores are twisted into triads – each triad covered with:</Text><Text id="19505" page="85">3. Fillers/Tape Flame retardant moisture resistant material , LSZH.</Text><Text id="19506" page="85">CABLE: Triads twisted into multi-triads - Triads twisted (10 to 14 twists/m) together are covered with:</Text><Text id="19507" page="85">4. Fillers/Tape Flame retardant moisture resistant material , LSZH.</Text><Text id="19508" page="85">5. Coll screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19509" page="85">6. Inner jacket Flame retardant Low Smoke Zero Halogen Compound LSZH. Colour: Black.</Text><Text id="19510" page="85">7. Inner Sheath Lead Sheath (or Lead pipe). A multi-layered Inner Sheath (AL/HDPE/PA instead of lead sheath) will be considered if the multi-layer sheath provides the same protection as a lead sheath for hydrocarbons, chemical and solvents, saline water ingress and vermin protection, as per BS 50288-7 section 4.18.2.</Text><Text id="19511" page="85">8. Bedding Flame retardant Low Smoke Zero Halogen Compound. Colour: Black.</Text><Text id="19513" page="85">10. Outer jacket Flame Retardant Low Smoke Zero Halogen Compound.</Text><Text id="19514" page="86">(C1) Single pair Thermocouple Extension, Type B, collective screen, unarmoured, flame retardant (Mica/XLPE/Coll Scr/LSHF) Voltage Rating: 300/500V</Text><Text id="19517" page="86">1. Conductor Type B Positive: Chromel Wire, Solid, Size: 1.5 mm² min Negative: Alumel Wire, Solid, Size: 1.5 mm² min Temperature rating 105°C.</Text><Text id="19519" page="86">2. Insulation Flame retardant material as per data sheet .</Text><Text id="19522" page="86">3. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19523" page="86">4. Cable screen One tinned copper 0.50 mm² min drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19524" page="86">5. Outer jacket Flame retardant Low Smoke Zero Halogen compound.</Text><Text id="19525" page="86">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’.</Text><Text id="19526" page="86">Note: This cable type shall be only utilized for indoor application where the cable is installed and fully routed within the same building.</Text><Text id="19529" page="87">1. Conductor Type K Positive: Chromel Wire, Solid, Size: 1.5 mm² min Negative: Alumel Wire, Solid, Size: 1.5 mm² min Temperature rating 105°C.</Text><Text id="19531" page="87">2. Insulation Flame retardant material as per data sheet.</Text><Text id="19535" page="87">4. Cable screen One tinned copper 0.50 mm² min drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19536" page="87">5. Outer jacket Flame retardant Low Smoke Zero Halogen compound.</Text><Text id="19537" page="87">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’.</Text><Text id="19538" page="87">Note: This cable type shall be only utilized for indoor application where the cable is installed and fully routed within the same building.</Text><Text id="19541" page="88">1. Conductor Type T Positive: Chromel Wire, Solid, Size: 1.5 mm² min Negative: Alumel Wire, Solid, Size: 1.5 mm² min Temperature rating 105°C.</Text><Text id="19543" page="88">2. Insulation Flame retardant material as per data sheet .</Text><Text id="19544" page="88">CABLE: Cores are twisted together and covered with:</Text><Text id="19545" page="88">3. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19546" page="88">4. Cable screen One tinned copper 0.50 mm² min drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19547" page="88">5. Outer jacket Flame retardant Low Smoke Zero Halogen compound.</Text><Text id="19548" page="88">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’.</Text><Text id="19549" page="88">Note: This cable type shall be only utilized for indoor application where the cable is installed and fully routed within the same building.</Text><Text id="19552" page="89">1. Conductor Type B Positive: Chromel Wire, Solid, Size: 1.5 mm² min Negative: Alumel Wire, Solid, Size: 1.5 mm² min Temperature rating 105°C.</Text><Text id="19554" page="89">2. Insulation Flame retardant material as per data sheet.</Text><Text id="19556" page="89">3. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19557" page="89">4. Cable screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19558" page="89">5. Inner jacket Flame retardant Low Smoke Zero Halogen Compound. Colour: Black.</Text><Text id="19560" page="89">7. Outer jacket Flame retardant Low Smoke Zero Halogen Compound.</Text><Text id="19561" page="89">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’.</Text><Text id="19564" page="90">1. Conductor Type K Positive: Chromel Wire, Solid, Size: 1.5 mm² min Negative: Alumel Wire, Solid, Size: 1.5 mm² min Temperature rating 105°C.</Text><Text id="19566" page="90">2. Insulation Flame retardant material as per data sheet.</Text><Text id="19568" page="90">3. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19569" page="90">4. Cable screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19570" page="90">5. Inner jacket Flame retardant Low Smoke Zero Halogen Compound. Colour: Black.</Text><Text id="19572" page="90">7. Outer jacket Flame retardant Low Smoke Zero Halogen Compound.</Text><Text id="19573" page="90">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’.</Text><Text id="19574" page="91">(C6) Single pair Thermocouple Extension, Type T, collective screen, armoured, flame retardant. (XLPE/Coll Scr/SWA/LSHF) Voltage Rating: 300/500V</Text><Text id="19577" page="91">1. Conductor Type T Positive: Chromel Wire, Solid, Size: 1.5 mm² min Negative: Alumel Wire, Solid, Size: 1.5 mm² min Temperature rating 105°C.</Text><Text id="19579" page="91">2. Insulation Flame retardant material as per data sheet.</Text><Text id="19581" page="91">3. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19582" page="91">4. Cable screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19583" page="91">5. Inner jacket Flame retardant Low Smoke Zero Halogen Compound. Colour: Black.</Text><Text id="19585" page="91">7. Outer jacket Flame retardant Low Smoke Zero Halogen Compound.</Text><Text id="19586" page="91">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’.</Text><Text id="19587" page="92">(C7) Multi-pair Thermocouple Extension, Type B, individual &amp; collective screen, armoured, flame retardant. (XLPE/Ind &amp; Coll Scr/SWA/LSHF) Voltage Rating: 300/500V</Text><Text id="19588" page="92">1 2 3 4 5 6 7 8 9</Text><Text id="19590" page="92">1. Conductor Type B Positive: Chromel Wire, Solid, Size: 1.0 mm² min Negative: Alumel Wire, Solid, Size: 1.0 mm² min Temperature rating 105°C.</Text><Text id="19592" page="92">2. Insulation Flame retardant material as per data sheet.</Text><Text id="19593" page="92">Cores are twisted into pairs – each pair covered with:</Text><Text id="19594" page="92">3. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19595" page="92">4. Ind screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19596" page="92">CABLE: Pairs are twisted into multi-pairs - Pairs twisted (10 to 14 twists/m) together are covered with:</Text><Text id="19597" page="92">5. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19598" page="92">6. Coll screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19599" page="92">7. Inner jacket Flame retardant Low Smoke Zero Halogen Compound. Colour: Black.</Text><Text id="19601" page="92">9. Outer jacket Flame retardant Low Smoke Zero Halogen Compound.</Text><Text id="19602" page="92">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’.</Text><Text id="19603" page="93">1 2 3 4 5 6 7 8 9</Text><Text id="19605" page="93">1. Conductor Type K Positive: Chromel Wire, Solid, Size: 1.0 mm² min Negative: Alumel Wire, Solid, Size: 1.0 mm² min Temperature rating 105°C.</Text><Text id="19607" page="93">2. Insulation Flame retardant material as per data sheet.</Text><Text id="19608" page="93">Cores are twisted into pairs – each pair covered with:</Text><Text id="19610" page="93">4. Ind screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19611" page="93">CABLE: Pairs are twisted into multi-pairs - Pairs twisted (10 to 14 twists/m) together are covered with:</Text><Text id="19612" page="93">5. Fillers Flame retardant moisture resistant material .</Text><Text id="19613" page="93">6. Coll screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19614" page="93">7. Inner jacket Flame retardant Low Smoke Zero Halogen Compound. Colour: Black.</Text><Text id="19616" page="93">9. Outer jacket Flame retardant Low Smoke Zero Halogen Compound.</Text><Text id="19617" page="93">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’.</Text><Text id="19618" page="94">(C9) Multi-pair Thermocouple Extension, Type T, individual &amp; collective screen, armoured, flame retardant. (XLPE/Ind &amp; Coll Scr/SWA/LSHF) Voltage Rating: 300/500V</Text><Text id="19619" page="94">1 2 3 4 5 6 7 8 9</Text><Text id="19621" page="94">1. Conductor Type T Positive: Chromel Wire, Solid, Size: 1.0 mm² min Negative: Alumel Wire, Solid, Size: 1.0 mm² min Temperature rating 105°C.</Text><Text id="19623" page="94">2. Insulation Flame retardant material as per data sheet.</Text><Text id="19624" page="94">Cores are twisted into pairs – each pair covered with:</Text><Text id="19625" page="94">3. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19626" page="94">4. Ind screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19627" page="94">CABLE: Pairs are twisted into multi-pairs - Pairs twisted (10 to 14 twists/m) together are covered with:</Text><Text id="19628" page="94">5. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19629" page="94">6. Coll screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19630" page="94">7. Inner jacket Flame retardant Low Smoke Zero Halogen Compound. Colour: Black.</Text><Text id="19632" page="94">9. Outer jacket Flame retardant Low Smoke Zero Halogen Compound.</Text><Text id="19633" page="94">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’.</Text><Text id="19634" page="95">(C10) Multi-pair Thermocouple Extension, Type B, individual &amp; collective screen, armoured, external buried, flame retardant. (XLPE/Ind &amp; Coll Scr/IS/SWA/LSHF) Voltage Rating: 300/500V</Text><Text id="19635" page="95">1 2 3 4 5 6 7 8 9 10 11</Text><Text id="19637" page="95">1. Conductor Type B Positive: Chromel Wire, Solid, Size: 1.0 mm² min Negative: Alumel Wire, Solid, Size: 1.0 mm² min Temperature rating 105°C.</Text><Text id="19639" page="95">2. Insulation Flame retardant material as per data sheet. Cores are twisted into pairs – each pair covered with:</Text><Text id="19640" page="95">3. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19641" page="95">4. Ind screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19642" page="95">CABLE: Pairs are twisted into multi-pairs - Pairs twisted (10 to 14 twists/m) together are covered with:</Text><Text id="19643" page="95">5. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19644" page="95">6. Coll screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19645" page="95">7. Inner jacket Flame retardant Low Smoke Zero Halogen Compound. Colour: Black.</Text><Text id="19646" page="95">8. Inner Sheath Lead Sheath (or Lead pipe). A multi-layered Inner Sheath (AL/HDPE/PA instead of lead sheath) will be considered if the multi-layer sheath provides the same protection as a lead sheath for hydrocarbons, chemical and solvents, saline water ingress and vermin protection, as per BS 50288-7 section 4.18.2.</Text><Text id="19647" page="95">9. Bedding Flame retardant Low Smoke Zero Halogen Compound. Colour: Black.</Text><Text id="19649" page="95">11. Outer jacket Flame retardant Low Smoke Zero Halogen Compound</Text><Text id="19650" page="96">1 2 3 4 5 6 7 8 9 10 11</Text><Text id="19652" page="96">1. Conductor Type K Positive: Chromel Wire, Solid, Size: 1.0 mm² min Negative: Alumel Wire, Solid, Size: 1.0 mm² min Temperature rating 105°C.</Text><Text id="19654" page="96">2. Insulation Flame retardant material as per data sheet. Cores are twisted into pairs – each pair covered with:</Text><Text id="19655" page="96">3. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19656" page="96">4. Ind screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19657" page="96">CABLE: Pairs are twisted into multi-pairs - Pairs twisted (10 to 14 twists/m) together are covered with:</Text><Text id="19658" page="96">5. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19659" page="96">6. Coll screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19660" page="96">7. Inner jacket Flame retardant Low Smoke Zero Halogen Compound. Colour: Black.</Text><Text id="19661" page="96">8. Inner Sheath Lead Sheath (or Lead pipe). A multi-layered Inner Sheath (AL/HDPE/PA instead of lead sheath) will be considered if the multi-layer sheath provides the same protection as a lead sheath for hydrocarbons, chemical and solvents, saline water ingress and vermin protection, as per BS 50288-7 section 4.18.2.</Text><Text id="19662" page="96">9. Bedding Flame retardant Low Smoke Zero Halogen Compound. Colour: Black.</Text><Text id="19664" page="97">(C12) Multi-pair Thermocouple Extension, Type T, individual &amp; collective screen, armoured, external buried, flame retardant. (XLPE/Ind &amp; Coll Scr/IS/SWA/LSHF) Voltage Rating: 300/500V</Text><Text id="19665" page="97">1 2 3 4 5 6 7 8 9 10 11</Text><Text id="19667" page="97">1. Conductor Type T Positive: Chromel Wire, Solid, Size: 1.0 mm² min Negative: Alumel Wire, Solid, Size: 1.0 mm² min Temperature rating 105°C.</Text><Text id="19669" page="97">2. Insulation Flame retardant material as per data sheet. Cores are twisted into pairs – each pair covered with:</Text><Text id="19670" page="97">3. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19671" page="97">4. Ind screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19672" page="97">CABLE: Pairs are twisted into multi-pairs - Pairs twisted (10 to 14 twists/m) together are covered with:</Text><Text id="19673" page="97">5. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19674" page="97">6. Coll screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19675" page="97">7. Inner jacket Flame retardant Low Smoke Zero Halogen Compound. Colour: Black.</Text><Text id="19676" page="97">8. Inner Sheath Lead Sheath (or Lead pipe). A multi-layered Inner Sheath (AL/HDPE/PA instead of lead sheath) will be considered if the multi-layer sheath provides the same protection as a lead sheath for hydrocarbons, chemical and solvents, saline water ingress and vermin protection, as per BS 50288-7 section 4.18.2.</Text><Text id="19677" page="97">9. Bedding Flame retardant Low Smoke Zero Halogen Compound. Colour: Black.</Text><Text id="19679" page="97">11. Outer jacket Flame retardant Low Smoke Zero Halogen Compound.</Text><Text id="19680" page="98">(D1) Single pair Thermocouple Extension, Type B, collective screen, unarmoured, fire resistant. (Mica/XLPE/Coll Scr/LSHF) Voltage Rating: 300/500V</Text><Text id="19683" page="98">1. Conductor Type B Positive: Chromel Wire, Solid, Size: 1.5 mm² min Negative: Alumel Wire, Solid, Size: 1.5 mm² min Temperature rating 105°C.</Text><Text id="19685" page="98">2. Insulation Mica impregnated glass tape beneath extruded layer of flame retardant cross linked Polyethylene (XLPE) or equivalent Ethylene Propylene Rubber (EPR) or equivalent Silicone Rubber (S95) or material as per data sheet.</Text><Text id="19687" page="98">3. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19688" page="98">4. Cable screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19689" page="98">5. Outer jacket Flame Retardant Low Smoke Zero Halogen Compound.</Text><Text id="19690" page="98">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’ and Fire Resistant to IEC 60331.</Text><Text id="19693" page="99">1. Conductor Type K Positive: Chromel Wire, Solid, Size: 1.5 mm² min Negative: Alumel Wire, Solid, Size: 1.5 mm² min Temperature rating 105°C.</Text><Text id="19695" page="99">2. Insulation Mica impregnated glass tape beneath extruded layer of flame retardant cross linked Polyethylene (XLPE) or equivalent Ethylene Propylene Rubber (EPR) or equivalent Silicone Rubber (S95) or material as per data sheet.</Text><Text id="19697" page="99">3. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19698" page="99">4. Cable screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19699" page="99">5. Outer jacket Flame Retardant Low Smoke Zero Halogen Compound.</Text><Text id="19700" page="99">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’ and Fire Resistant to IEC 60331.</Text><Text id="19703" page="100">1. Conductor Type T Positive: Chromel Wire, Solid, Size: 1.5 mm² min Negative: Alumel Wire, Solid, Size: 1.5 mm² min Temperature rating 105°C.</Text><Text id="19705" page="100">2. Insulation Mica impregnated glass tape beneath extruded layer of flame retardant cross linked Polyethylene (XLPE) or equivalent Ethylene Propylene Rubber (EPR) or equivalent Silicone Rubber (S95) or material as per data sheet.</Text><Text id="19707" page="100">3. Fillers Flame retardant moisture resistant material .</Text><Text id="19708" page="100">4. Cable screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19709" page="100">5. Outer jacket Flame Retardant Low Smoke Zero Halogen Compound.</Text><Text id="19710" page="100">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’ and Fire Resistant to IEC 60331.</Text><Text id="19713" page="101">1. Conductor Type B Positive: Chromel Wire, Solid, Size: 1.5 mm² min Negative: Alumel Wire, Solid, Size: 1.5 mm² min Temperature rating 105°C.</Text><Text id="19715" page="101">2. Insulation Mica impregnated glass tape beneath extruded layer of flame retardant cross linked Polyethylene (XLPE) or equivalent Ethylene Propylene Rubber (EPR) or equivalent Silicone Rubber (S95) or material as per data sheet.</Text><Text id="19717" page="101">3. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19718" page="101">4. Cable screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19719" page="101">5. Inner jacket Flame retardant Low Smoke Zero Halogen Compound.</Text><Text id="19722" page="101">7. Outer jacket Flame Retardant Low Smoke Zero Halogen Compound.</Text><Text id="19723" page="101">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’ and Fire Resistant to IEC 60331.</Text><Text id="19726" page="102">1. Conductor Type K Positive: Chromel Wire, Solid, Size: 1.5 mm² min Negative: Alumel Wire, Solid, Size: 1.5 mm² min Temperature rating 105°C.</Text><Text id="19728" page="102">2. Insulation Mica impregnated glass tape beneath extruded layer of flame retardant cross linked Polyethylene (XLPE) or equivalent Ethylene Propylene Rubber (EPR) or equivalent Silicone Rubber (S95) or material as per data sheet.</Text><Text id="19730" page="102">3. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19731" page="102">4. Cable screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19732" page="102">5. Inner jacket Flame retardant Low Smoke Zero Halogen Compound Colour: Black.</Text><Text id="19734" page="102">7. Outer jacket Flame Retardant Low Smoke Zero Halogen Compound.</Text><Text id="19735" page="102">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’ and Fire Resistant to IEC 60331.</Text><Text id="19736" page="103">(D6) Single pair Thermocouple Extension, Type T, collective screen, armoured, fire resistant. (XLPE/Coll Scr/SWA/LSHF) Voltage Rating: 300/500V</Text><Text id="19739" page="103">1. Conductor Type T Positive: Chromel Wire, Solid, Size: 1.5 mm² min Negative: Alumel Wire, Solid, Size: 1.5 mm² min Temperature rating 105°C.</Text><Text id="19741" page="103">2. Insulation Mica impregnated glass tape beneath extruded layer of flame retardant cross linked Polyethylene (XLPE) or equivalent Ethylene Propylene Rubber (EPR) or equivalent Silicone Rubber (S95) or material as per data sheet.</Text><Text id="19743" page="103">3. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19744" page="103">4. Cable screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19745" page="103">5. Inner jacket Flame retardant Low Smoke Zero Halogen Compound.</Text><Text id="19748" page="103">7. Outer jacket Flame Retardant Low Smoke Zero Halogen Compound.</Text><Text id="19749" page="103">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’ and Fire Resistant to IEC 60331.</Text><Text id="19750" page="104">(D7) Multi-pair Thermocouple Extension, Type B, individual &amp; collective screen, armoured, fire resistant. (XLPE/Ind &amp; Coll Scr/SWA/LSHF) Voltage Rating: 300/500V</Text><Text id="19751" page="104">1 2 3 4 5 6 7 8 9</Text><Text id="19753" page="104">1. Conductor Type B Positive: Chromel Wire, Solid, Size: 1.0 mm² min Negative: Alumel Wire, Solid, Size: 1.0 mm² min Temperature rating 105°C.</Text><Text id="19755" page="104">2. Insulation Mica impregnated glass tape beneath extruded layer of flame retardant cross linked Polyethylene (XLPE) or equivalent Ethylene Propylene Rubber (EPR) or equivalent Silicone Rubber (S95) or material as per data sheet.</Text><Text id="19756" page="104">Cores are twisted into pairs – each pair covered with:</Text><Text id="19757" page="104">3. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19758" page="104">4. Ind screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19759" page="104">CABLE: Pairs are twisted into multi-pairs - Pairs twisted (10 to 14 twists/m) together are covered with:</Text><Text id="19760" page="104">5. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19761" page="104">6. Coll screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19762" page="104">7. Inner jacket Flame retardant Low Smoke Zero Halogen Compound.</Text><Text id="19765" page="104">9. Outer jacket Flame Retardant Low Smoke Zero Halogen Compound.</Text><Text id="19766" page="105">1 2 3 4 5 6 7 8 9</Text><Text id="19768" page="105">1. Conductor Type K Positive: Chromel Wire, Solid, Size: 1.0 mm² min Negative: Alumel Wire, Solid, Size: 1.0 mm² min Temperature rating 105°C.</Text><Text id="19770" page="105">2. Insulation Mica impregnated glass tape beneath extruded layer of flame retardant cross linked Polyethylene (XLPE) or equivalent Ethylene Propylene Rubber (EPR) or equivalent Silicone Rubber (S95) or material as per data sheet.</Text><Text id="19771" page="105">Cores are twisted into pairs – each pair covered with:</Text><Text id="19772" page="105">3. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19773" page="105">4. Ind screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19774" page="105">CABLE: Pairs are twisted into multi-pairs - Pairs twisted (10 to 14 twists/m) together are covered with:</Text><Text id="19775" page="105">5. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19776" page="105">6. Coll screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19777" page="105">7. Inner jacket Flame retardant Low Smoke Zero Halogen Compound.</Text><Text id="19780" page="105">9. Outer jacket Flame Retardant Low Smoke Zero Halogen Compound.</Text><Text id="19781" page="106">(D9) Multi-pair Thermocouple Extension, Type T, individual &amp; collective screen, armoured, fire resistant. (XLPE/Ind &amp; Coll Scr/SWA/LSHF) Voltage Rating: 300/500V</Text><Text id="19782" page="106">1 2 3 4 5 6 7 8 9</Text><Text id="19784" page="106">1. Conductor Type T Positive: Chromel Wire, Solid, Size: 1.0 mm² min Negative: Alumel Wire, Solid, Size: 1.0 mm² min Temperature rating 105°C.</Text><Text id="19786" page="106">2. Insulation Mica impregnated glass tape beneath extruded layer of flame retardant cross linked Polyethylene (XLPE) or equivalent Ethylene Propylene Rubber (EPR) or equivalent Silicone Rubber (S95) or material as per data sheet.</Text><Text id="19787" page="106">Cores are twisted into pairs – each pair covered with:</Text><Text id="19788" page="106">3. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19789" page="106">4. Ind screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19790" page="106">CABLE: Pairs are twisted into multi-pairs - Pairs twisted (10 to 14 twists/m) together are covered with:</Text><Text id="19791" page="106">5. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19792" page="106">6. Coll screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19793" page="106">7. Inner jacket Flame retardant Low Smoke Zero Halogen Compound.</Text><Text id="19796" page="106">9. Outer jacket Flame Retardant Low Smoke Zero Halogen Compound.</Text><Text id="19797" page="107">(D10) Multi-pair Thermocouple Extension, Type B, individual &amp; collective screen, armoured, external buried, fire resistant. (XLPE/Ind &amp; Coll Scr/IS/SWA/LSHF) Voltage Rating: 300/500V</Text><Text id="19798" page="107">1 2 3 4 5 6 7 8 9 10 11</Text><Text id="19800" page="107">1. Conductor Type B Positive: Chromel Wire, Solid, Size: 1.0 mm² min Negative: Alumel Wire, Solid, Size: 1.0 mm² min Temperature rating 105°C.</Text><Text id="19802" page="107">2. Insulation Mica impregnated glass tape beneath extruded layer of flame retardant cross</Text><Text id="19803" page="107">linked Polyethylene (XLPE) or equivalent Ethylene Propylene Rubber (EPR) or equivalent Silicone Rubber (S95) or material as per data sheet. Cores are twisted into pairs – each pair covered with:</Text><Text id="19804" page="107">3. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19805" page="107">4. Ind screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19806" page="107">CABLE: Pairs are twisted into multi-pairs - Pairs twisted (10 to 14 twists/m) together are covered with:</Text><Text id="19807" page="107">5. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19808" page="107">6. Coll screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19809" page="107">7. Inner jacket Flame retardant Low Smoke Zero Halogen Compound. Colour: Black.</Text><Text id="19810" page="107">8. Inner Sheath Lead Sheath (or Lead pipe). A multi-layered Inner Sheath (AL/HDPE/PA instead of lead sheath) will be considered if the multi-layer sheath provides the same protection as a lead sheath for hydrocarbons, chemical and solvents, saline water ingress and vermin protection, as per BS 50288-7 section 4.18.2.</Text><Text id="19811" page="107">9. Bedding Flame retardant Low Smoke Zero Halogen Compound.</Text><Text id="19814" page="107">11. Outer jacket Flame Retardant Low Smoke Zero Halogen Compound.</Text><Text id="19815" page="108">1 2 3 4 5 6 7 8 9 10 11</Text><Text id="19817" page="108">1. Conductor Type K Positive: Chromel Wire, Solid, Size: 1.0 mm² min Negative: Alumel Wire, Solid, Size: 1.0 mm² min Temperature rating 105°C.</Text><Text id="19819" page="108">2. Insulation Mica impregnated glass tape beneath extruded layer of flame retardant cross</Text><Text id="19820" page="108">linked Polyethylene (XLPE) or equivalent Ethylene Propylene Rubber (EPR) or equivalent Silicone Rubber (S95) or material as per data sheet. Cores are twisted into pairs – each pair covered with:</Text><Text id="19821" page="108">3. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19822" page="108">4. Ind screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19823" page="108">CABLE: Pairs are twisted into multi-pairs - Pairs twisted (10 to 14 twists/m) together are c overed with:</Text><Text id="19824" page="108">5. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19825" page="108">6. Coll screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19826" page="108">7. Inner jacket Flame retardant Low Smoke Zero Halogen Compound. Colour: Black.</Text><Text id="19827" page="108">8. Inner Sheath Lead Sheath (or Lead pipe). A multi-layered Inner Sheath (AL/HDPE/PA instead of lead sheath) will be considered if the multi-layer sheath provides the same protection as a lead sheath for hydrocarbons, chemical and solvents, saline water ingress and vermin protection, as per BS 50288-7 section 4.18.2.</Text><Text id="19828" page="108">9. Bedding Flame retardant Low Smoke Zero Halogen Compound</Text><Text id="19831" page="108">11. Outer jacket Flame retardant Low Smoke Zero Halogen Compound.</Text><Text id="19832" page="109">(D12) Multi-pair Thermocouple Extension, Type T, individual &amp; collective screen, armoured, external buried, fire resistant. (XLPE/Ind &amp; Coll Scr/IS/SWA/LSHF) Voltage Rating: 300/500V</Text><Text id="19833" page="109">1 2 3 4 5 6 7 8 9 10 11</Text><Text id="19835" page="109">1. Conductor Type T Positive: Chromel Wire, Solid, Size: 1.0 mm² min Negative: Alumel Wire, Solid, Size: 1.0 mm² min Temperature rating 105°C.</Text><Text id="19837" page="109">2. Insulation Mica impregnated glass tape beneath extruded layer of flame retardant cross</Text><Text id="19838" page="109">linked Polyethylene (XLPE) or equivalent Ethylene Propylene Rubber (EPR) or equivalent Silicone Rubber (S95) or material as per data sheet. Cores are twisted into pairs – each pair covered with:</Text><Text id="19839" page="109">3. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19840" page="109">4. Ind screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19841" page="109">CABLE: Pairs are twisted into multi-pairs - Pairs twisted (10 to 14 twists/m) together are covered with:</Text><Text id="19842" page="109">5. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="19843" page="109">6. Coll screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="19844" page="109">7. Inner jacket Flame retardant Low Smoke Zero Halogen Compound. Colour: Black.</Text><Text id="19845" page="109">8. Inner Sheath Lead Sheath (or Lead pipe). A multi-layered Inner Sheath (AL/HDPE/PA instead of lead sheath) will be considered if the multi-layer sheath provides the same protection as a lead sheath for hydrocarbons, chemical and solvents, saline water ingress and vermin protection, as per BS 50288-7 section 4.18.2.</Text><Text id="19846" page="109">9. Bedding Flame retardant Low Smoke Zero Halogen Compound.</Text><Text id="19849" page="109">11. Outer jacket Flame retardant Low Smoke Zero Halogen Compound.</Text><Text id="19850" page="110">(E1) Communication, 2 wire applications, Single-pair, foil shield and braid, unarmoured, flame retardant. (XLPE/Coll Scr/LSHF) Voltage Rating: 300/500V</Text><Text id="19853" page="110">1. Conductors Stranded annealed copper. Circular section, Type A according to IEC 61158-2. Temperature rating 90°C Size 1.5 mm 2 min for `Foundation Fieldbus’ and RS-485 signals.</Text><Text id="19855" page="110">2. Insulation Flame retardant material as per data sheet. CABLE:</Text><Text id="19857" page="110">3. Foil Overall foil (aluminium foil, polyester tape coated on one surface) shield with metal surface in contact with one tinned copper drain wire . Together with Flame retardant moisture resistant material fillers.</Text><Text id="19858" page="110">4. Braid Tinned copper wire braid in continuous contact with the tinned copper drain wire.</Text><Text id="19859" page="110">5. Outer jacket Flame retardant Low Smoke Zero Halogen Compound.</Text><Text id="19860" page="110">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A.</Text><Text id="19861" page="110">Note: This cable type shall be only utilized for indoor application where the cable is installed and fully routed within the same building.</Text><Text id="19862" page="110">(E2) Communication, 2wire applications, Multi-pair, foil shield, unarmoured, flame retardant. (XLPE/Ind &amp; Coll Scr/LSHF)</Text><Text id="19865" page="111">1. Conductors Stranded annealed copper. Circular section, Type A according to IEC 61158-2 and Foundation Fieldbus Cable Specification FF-844 H1. Temperature rating 90°C. Size: 1.0 mm² min for `Foundation Fieldbus’ and RS-485 signals.</Text><Text id="19866" page="111">Identification Orange (+) and Blue (-). Each core printed with pair number throughout the cable at equal distances.</Text><Text id="19867" page="111">2. Insulation Flame retardant material as per data sheet.</Text><Text id="19868" page="111">CABLE: Cores are twisted together and covered with:</Text><Text id="19869" page="111">3. Ind Foil Individual foil (aluminium foil, polyester tape coated on one surface) shield with metal surface in contact with one tinned copper drain wire . Together with Flame retardant moisture resistant material fillers.</Text><Text id="19870" page="111">4. Coll Foil Collective foil (aluminium foil, polyester tape coated on one surface) shield with metal surface in contact with one tinned copper drain wire .</Text><Text id="19871" page="111">5. Outer jacket Flame Retardant Low Smoke Zero Halogen compound.</Text><Text id="19872" page="111">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’.</Text><Text id="19873" page="111">Note: This cable type shall be only utilized for indoor application where the cable is installed and fully routed within the same building.</Text><Text id="19874" page="112">(E3) Communication, 2wire applications, Single-pair, foil shield, armoured, flame retardant. (XLPE/Coll Scr/SWA/LSHF) Voltage Rating: 300/500V</Text><Text id="19877" page="112">1. Conductors Standed annealed copper. Circular section, Type A according to IEC 61158-2. Temperature rating 90°C Size 1.5 mm 2 min for `Foundation Fieldbus’ and RS-485 signals.</Text><Text id="19879" page="112">2. Insulation Flame retardant material as per data sheet.</Text><Text id="19880" page="112">CABLE: Cores are twisted together and covered with:</Text><Text id="19881" page="112">3. Coll Foil Collective foil (aluminium foil, polyester tape coated on one surface) shield with metal surface in contact with one tinned copper drain wire . Together with Flame retardant moisture resistant material fillers.</Text><Text id="19882" page="112">4. Inner jacket Flame retardant Low Smoke Zero Halogen Compound.</Text><Text id="19884" page="112">6. Outer jacket Flame retardant Low Smoke Zero Halogen compound.</Text><Text id="19885" page="112">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’.</Text><Text id="19886" page="113">(E4) Communication, 2wire applications, Multi-pair, foil shield, armoured, flame retardant. (XLPE/Ind &amp; Coll Scr/SWA/LSHF) Voltage Rating: 300/500V</Text><Text id="19889" page="113">1. Conductors Stranded annealed copper. Circular section, Type A according to IEC 61158-22 and Foundation Fieldbus Cable Specification FF-844 H1. Temperature rating 90°C. Size: 1.0 mm² min for `Foundation Fieldbus’ and RS-485 signals.</Text><Text id="19890" page="113">Identification Orange (+) and Blue (-). Each core printed with pair number throughout the cable at equal distances.</Text><Text id="19891" page="113">2. Insulation Flame retardant material as per data sheet.</Text><Text id="19892" page="113">CABLE: Cores are twisted together and covered with:</Text><Text id="19893" page="113">3. Ind Foil Individual foil (aluminium foil, polyester tape coated on one surface) shield with metal surface in contact with one tinned copper drain wire . Together with Flame retardant moisture resistant material fillers.</Text><Text id="19894" page="113">4. Coll Foil Collective foil (aluminium foil, polyester tape coated on one surface) shield with metal surface in contact with one tinned copper drain wire.</Text><Text id="19895" page="113">5. Inner jacket Flame retardant Low Smoke Zero Halogen Compound.</Text><Text id="19897" page="113">7. Outer jacket Flame Retardant Low Smoke Zero Halogen compound.</Text><Text id="19898" page="113">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’.</Text><Text id="19899" page="114">(E5) Communication, 2wire applications, Single-pair, foil shield, armoured, external buried, flame retardant. (XLPE/Coll Scr/LS/SWA/LSHF) Voltage Rating: 300/500V</Text><Text id="19900" page="114">1 2 3 4 5 6 7 8</Text><Text id="19902" page="114">1. Conductors Stranded annealed copper. Circular section, Class 2 according to IEC 60228. Temperature rating 90°C. Size: 1.5 mm² min for `Foundation Fieldbus’ and RS-485 signals.</Text><Text id="19904" page="114">2. Insulation Flame retardant material as per data sheet.</Text><Text id="19905" page="114">CABLE: Cores are twisted together and covered with:</Text><Text id="19906" page="114">3. Coll Foil Collective foil (aluminium foil, polyester tape coated on one surface) shield with metal surface in contact with one tinned copper drain wire . Together with Flame retardant moisture resistant material fillers and PETP binder tape.</Text><Text id="19907" page="114">4. Inner jacket Flame retardant Low Smoke Zero Halogen Compound ,LSZH. Colour: Black.</Text><Text id="19908" page="114">5. Inner Sheath Lead Sheath (or Lead pipe). A multi-layered Inner Sheath (AL/HDPE/PA instead of lead sheath) will be considered if the multi-layer sheath provides the same protection as a lead sheath for hydrocarbons, chemical and solvents, saline water ingress and vermin protection, as per BS 50288-7 section 4.18.2.</Text><Text id="19909" page="114">6. Bedding Flame retardant Low Smoke Zero Halogen Compound. Colour: Black.</Text><Text id="19911" page="114">8. Outer jacket Flame Retardant Low Smoke Zero Halogen compound.</Text><Text id="19912" page="114">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’.</Text><Text id="19913" page="115">(E6) Communication, 2-wire applications, Multi-pair, foil shield, armoured, external buried, flame retardant. (XLPE/Ind &amp; Coll Scr/LS/SWA/LSHF) Voltage Rating: 300/500V</Text><Text id="19914" page="115">1 2 3 4 5 6 7 8 9</Text><Text id="19916" page="115">1. Conductors Stranded annealed copper. Circular section, Class 2 according to IEC 60228 and Foundation Fieldbus Cable Specification FF-844 H1. Temperature rating 90°C. Size: 1.0 mm² min for `Foundation Fieldbus’ and RS-485 signals.</Text><Text id="19917" page="115">Identification Orange (+) and Blue (-). Each core printed with pair number throughout the cable at equal distances.</Text><Text id="19918" page="115">2. Insulation Flame retardant material as per data sheet. CABLE:</Text><Text id="19919" page="115">Cores are twisted into pairs – each pair covered with:</Text><Text id="19920" page="115">3. Ind Foil Individual foil (aluminium foil, polyester tape coated on one surface) shield with metal surface in contact with one tinned copper drain wire . Together with Flame retardant moisture resistant material fillers.</Text><Text id="19921" page="115">4. Coll Foil Collective foil (aluminium foil, polyester tape coated on one surface) shield with metal surface in contact with one tinned copper drain wire.</Text><Text id="19922" page="115">5. Inner jacket Flame retardant Low Smoke Zero Halogen Compound ,LSZH. Colour: Black.</Text><Text id="19923" page="115">6. Inner Sheath Lead Sheath (or Lead pipe). A multi-layered Inner Sheath (AL/HDPE/PA instead of lead sheath) will be considered if the multi-layer sheath provides the same protection as a lead sheath for hydrocarbons, chemical and solvents, saline water ingress and vermin protection, as per BS 50288-7 section 4.18.2.</Text><Text id="19924" page="115">7. Bedding Flame retardant Low Smoke Zero Halogen Compound. Colour: Black.</Text><Text id="19926" page="115">9. Outer jacket Flame Retardant Low Smoke Zero Halogen Compound.</Text><Text id="19927" page="116">(E7) RS232/422/485 Communication, 4wire applications, overall screen, unarmoured, flame retardant. (XLPE/OS/LSHF) Voltage Rating: 300/500V</Text><Text id="19930" page="116">1. Conductors 2Pair, Stranded annealed copper. Circular section, TypeA according to IEC 61158-</Text><Text id="19931" page="116">2 Temperature rating 90°C. Size: 1.5 mm² min for 4-wire serial communications.</Text><Text id="19932" page="116">Identification Pair1 - White/Blue stripe and Blue/White stripe Pair2 - White/Orange stripe and Orange/White stripe.</Text><Text id="19933" page="116">2. Insulation Flame retardant material as per data sheet .</Text><Text id="19936" page="116">3. Coll Foil Overall foil shield with one tinned copper drain wire .</Text><Text id="19937" page="116">4. Braid Tinned copper braid in continuous contact with the tinned copper drain wire.</Text><Text id="19938" page="116">5. Outer jacket Flame Retardant Low Smoke Zero Halogen Compound.</Text><Text id="19939" page="116">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’.</Text><Text id="19940" page="116">Note: This cable type shall be only utilized for indoor application where the cable is installed and fully routed within the same building.</Text><Text id="19941" page="117">(E8) RS232/422/485 Communication, 4wire applications, overall screen, armoured, flame retardant. (XLPE/OS/SWA/LSHF) Voltage Rating: 300/500V</Text><Text id="19944" page="117">1. Conductors 2Pair, Stranded annealed copper, Circular section, Type A as per IEC 61158-2. Temperature rating 90°C. Size: 1.5 mm² min for 4-wire serial communications.</Text><Text id="19945" page="117">Identification Pair1 - White/Blue stripe and Blue/White stripe Pair2 - White/Orange stripe and Orange/White stripe.</Text><Text id="19946" page="117">2. Insulation Flame retardant material as per data sheet.</Text><Text id="19949" page="117">3. Coll Foil Overall foil shield with one tinned copper drain wire .</Text><Text id="19950" page="117">4. Braid Tinned copper braid in continuous contact with the tinned copper drain wire.</Text><Text id="19951" page="117">5. Inner jacket Flame retardant Low Smoke Zero Halogen Compound , LSZH. Colour: Black.</Text><Text id="19953" page="117">7. Outer jacket Flame Retardant Low Smoke Zero Halogen Compound.</Text><Text id="19954" page="117">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’.</Text><Text id="19955" page="117">(F1) Communication, 2wire applications, Single-pair, foil shield and braid, unarmoured, fire resistant. (XLPE/Coll Scr/LSHF) Voltage Rating: 300/500V</Text><Text id="19958" page="118">1. Conductors Stranded annealed copper. Circular section, Type A according to IEC 61158-2. Temperature rating 90°C Size 1.5 mm 2 min for `Foundation Fieldbus’ and RS-485 signals.</Text><Text id="19960" page="118">2. Insulation Mica impregnated glass tape beneath extruded layer of flame retardant cross linked Polyethylene (XLPE) or equivalent Ethylene Propylene Rubber (EPR) or equivalent Silicone Rubber (S95) or material as per data sheet.</Text><Text id="19961" page="118">CABLE: Cores are twisted together and covered with:</Text><Text id="19962" page="118">3. Coll Foil Overall foil (aluminium tape plastic coated on one surface) shield with metal surface in contact with one tinned copper drain wire .</Text><Text id="19963" page="118">4. Braid Tinned copper wire braid in continuous contact with the tinned copper drain wire.</Text><Text id="19964" page="118">5. Outer jacket Flame retardant Low Smoke Zero Halogen Compound.</Text><Text id="19965" page="118">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’ and Fire Resistant to IEC 60331.</Text><Text id="19966" page="118">Note: This cable type shall be only utilized for indoor application where the cable is installed and fully routed within the same building.</Text><Text id="19967" page="119">(F2) Communication, 2wire applications, Multi-pair, foil shield and braid, unarmoured, fire resistant. (XLPE/Ind &amp; Coll Scr/LSHF) Voltage Rating: 300/500V</Text><Text id="19970" page="119">1. Conductors Stranded annealed copper. Circular section, Type A according to IEC 61158-2 and Foundation Fieldbus Cable Specification FF-844 H1. Temperature rating 90°C. Size: 1.0 mm² min for `Foundation Fieldbus’ and RS-485 signals.</Text><Text id="19971" page="119">Identification Orange (+) and Blue (-). Each core printed with pair number throughout the cable at equal distances.</Text><Text id="19972" page="119">2. Insulation Mica impregnated glass tape beneath extruded layer of flame retardant cross linked Polyethylene (XLPE) or equivalent Ethylene Propylene Rubber (EPR) or equivalent Silicone Rubber (S95) or material as per data sheet.</Text><Text id="19973" page="119">CABLE: Cores are twisted together and covered with:</Text><Text id="19974" page="119">3. Ind Foil Individual foil (aluminium foil, polyester tape coated on one surface) shield with metal surface in contact with one tinned copper drain wire . Together with Flame retardant moisture resistant material fillers.</Text><Text id="19975" page="119">4. Coll Foil Collective foil (aluminium foil, polyester tape coated on one surface) shield with metal surface in contact with one tinned copper drain wire .</Text><Text id="19976" page="119">5. Braid Tinned copper wire braid in continuous contact with the tinned copper drain wire.</Text><Text id="19977" page="119">6. Outer jacket Flame Retardant Low Smoke Zero Halogen Compound.</Text><Text id="19978" page="119">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’ and Fire Resistant to IEC 60331.</Text><Text id="19979" page="120">(F3) Communication, 2wire applications, Single-pair, foil shield, armoured, fire resistant. (XLPE/Coll Scr/SWA/LSHF) Voltage Rating: 300/500V</Text><Text id="19982" page="120">1. Conductors Stranded annealed copper. Circular section, Type A according to IEC 61158-2. Temperature rating 90°C Size 1.5 mm 2 min for `Foundation Fieldbus’ and RS-485 signals.</Text><Text id="19984" page="120">2. Insulation Mica impregnated glass tape beneath extruded layer of flame retardant cross linked Polyethylene (XLPE) or equivalent Ethylene Propylene Rubber (EPR) or equivalent Silicone Rubber (S95) or material as per data sheet.</Text><Text id="19985" page="120">CABLE: Cores are twisted together and covered with:</Text><Text id="19986" page="120">3. Coll Foil Overall foil (aluminium tape plastic coated on one surface) shield with metal surface in contact with one tinned copper drain wire .</Text><Text id="19987" page="120">4. Inner jacket Flame retardant Low Smoke Zero Halogen Compound , LSZH Colour: Black.</Text><Text id="19989" page="120">6. Outer jacket Flame Retardant Low Smoke Zero Halogen Compound.</Text><Text id="19990" page="120">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’ and Fire Resistant to IEC 60331.</Text><Text id="19991" page="121">(F4) Communication, 2wire applications, Multi-pair, foil shield, armoured, fire resistant. (XLPE/Ind &amp; Coll Scr/SWA/LSHF) Voltage Rating: 300/500V</Text><Text id="19994" page="121">1. Conductors Stranded annealed copper. Circular section, Type A according to IEC 61158-2 and Foundation Fieldbus Cable Specification FF-844 H1. Temperature rating 90°C Size 1.0 mm 2 min for `Foundation Fieldbus’ and RS-485 signals.</Text><Text id="19996" page="121">2. Insulation Mica impregnated glass tape beneath extruded layer of flame retardant cross linked Polyethylene (XLPE) or equivalent Ethylene Propylene Rubber (EPR) or equivalent Silicone Rubber (S95) or material as per data sheet.</Text><Text id="19997" page="121">CABLE: Cores are twisted together and covered with:</Text><Text id="19998" page="121">3. Ind Foil Individual foil (aluminium foil, polyester tape coated on one surface) shield with metal surface in contact with one tinned copper drain wire . Together with Flame retardant moisture resistant material fillers.</Text><Text id="19999" page="121">4. Coll Foil Collective foil (aluminium foil, polyester tape coated on one surface) shield with metal surface in contact with one tinned copper drain wire .</Text><Text id="20000" page="121">5. Inner jacket Flame retardant Low Smoke Zero Halogen Compound ,LSZH. Colour: Black.</Text><Text id="20002" page="121">7. Outer jacket Flame Retardant Low Smoke Zero Halogen Compound.</Text><Text id="20003" page="122">(F5) Communication, 2wire applications, Single-pair, foil shield, armoured, external buried, fire resistant. (XLPE/Coll Scr/LS/SWA/LSHF) Voltage Rating: 300/500V</Text><Text id="20004" page="122">1 2 3 4 5 6 7 8</Text><Text id="20006" page="122">1. Conductors Stranded annealed copper. Circular section, Type A according to IEC 61158-2. Temperature rating 90°C Size 1.5 mm 2 min for `Foundation Fieldbus’ and RS-485 signals.</Text><Text id="20008" page="122">2. Insulation Mica impregnated glass tape beneath extruded layer of flame retardant cross linked Polyethylene (XLPE) or equivalent Ethylene Propylene Rubber (EPR) or equivalent Silicone Rubber (S95) or material as per data sheet.</Text><Text id="20009" page="122">CABLE: Cores are twisted together and covered with:</Text><Text id="20010" page="122">3. Coll Foil Collective foil (aluminium foil, polyester tape coated on one surface) shield with metal surface in contact with one tinned copper drain wire . Together with Flame retardant moisture resistant material fillers and PETP binder tape.</Text><Text id="20011" page="122">4. Inner jacket Flame retardant Low Smoke Zero Halogen Compound. Colour: Black.</Text><Text id="20012" page="122">5. Inner Sheath Lead Sheath (or Lead pipe). A multi-layered Inner Sheath (AL/HDPE/PA instead of lead sheath) will be considered if the multi-layer sheath provides the same protection as a lead sheath for hydrocarbons, chemical and solvents, saline water ingress and vermin protection, as per BS 50288-7 section 4.18.2.</Text><Text id="20013" page="122">6. Bedding Flame retardant Low Smoke Zero Halogen Compound ,LSZH.</Text><Text id="20016" page="122">8. Outer jacket Flame Retardant Low Smoke Zero Halogen Compound.</Text><Text id="20017" page="122">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’ and Fire Resistant to IEC 60331.</Text><Text id="20018" page="123">(F6) Communication, 2wire applications, Multi-pair, foil shield, armoured, external buried, fire resistant. (XLPE/Ind &amp; Coll Scr/LS/SWA/LSHF) Voltage Rating: 300/500V</Text><Text id="20020" page="123">1 2 3 4 5 6 7 8 9</Text><Text id="20021" page="123">1. Conductors Stranded annealed copper. Circular section, Type A according to IEC 61158-2 and Foundation Fieldbus Cable Specification FF-844 H1. Temperature rating 90°C Size 1.0 mm 2 min for `Foundation Fieldbus’ and RS-485 signals.</Text><Text id="20023" page="123">2. Insulation Mica impregnated glass tape beneath extruded layer of flame retardant cross linked Polyethylene (XLPE) or equivalent Ethylene Propylene Rubber (EPR) or equivalent Silicone Rubber (S95) or material as per data sheet.</Text><Text id="20024" page="123">CABLE: Cores are twisted together and covered with:</Text><Text id="20025" page="123">3. Ind Foil Individual foil (aluminium foil, polyester tape coated on one surface) shield with metal surface in contact with one tinned copper drain wire . Together with Flame retardant moisture resistant material fillers.</Text><Text id="20026" page="123">4. Coll Foil Collective foil (aluminium foil, polyester tape coated on one surface) shield with metal surface in contact with one tinned copper drain wire .</Text><Text id="20027" page="123">5. Inner jacket Flame retardant Low Smoke Zero Halogen Compound ,LSZH. Colour: Black.</Text><Text id="20028" page="123">6. Inner Sheath Lead Sheath (or Lead pipe). A multi-layered Inner Sheath (AL/HDPE/PA instead of lead sheath) will be considered if the multi-layer sheath provides the same protection as a lead sheath for hydrocarbons, chemical and solvents, saline water ingress and vermin protection, as per BS 50288-7 section 4.18.2.</Text><Text id="20029" page="123">7. Bedding Flame retardant Low Smoke Zero Halogen Compound ,LSZH.</Text><Text id="20032" page="123">9. Outer jacket Flame Retardant Low Smoke Zero Halogen Compound.</Text><Text id="20033" page="124">(F7) RS232/422/485 Communication, 4wire applications, overall screen, unarmoured, fire resistant. (XLPE/OS/LSHF) Voltage Rating: 300/500V</Text><Text id="20036" page="124">1. Conductors 2Pair, Stranded annealed copper. Circular section, TypeA according to IEC 61158-</Text><Text id="20037" page="124">2. Temperature rating 90°C. Size: 1.5 mm² min for 4-wire serial communications.</Text><Text id="20038" page="124">Identification Pair1 - White/Blue stripe and Blue/White stripe Pair2 - White/Orange stripe and Orange/White stripe.</Text><Text id="20039" page="124">2. Insulation Mica impregnated glass tape beneath extruded layer of flame retardant cross linked Polyethylene (XLPE) or equivalent Ethylene Propylene Rubber (EPR) or equivalent Silicone Rubber (S95) or material as per data sheet.</Text><Text id="20042" page="124">3. Coll Foil Overall foil shield with one tinned copper drain wire.</Text><Text id="20043" page="124">4. Braid Tinned copper braid in continuous contact with the tinned copper drain wire.</Text><Text id="20044" page="124">5. Outer jacket Flame Retardant Low Smoke Zero Halogen Compound.</Text><Text id="20045" page="124">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’ and Fire Resistant to IEC 60331.</Text><Text id="20046" page="124">Note: This cable type shall be only utilized for indoor application where the cable is installed and fully routed within the same building.</Text><Text id="20047" page="125">(F8) RS232/422/485 Communication, 4wire applications, overall screen, armoured, fire resistant. (XLPE/OS/SWA/LSHF) Voltage Rating: 300/500V</Text><Text id="20050" page="125">1. Conductors 2Pair, Stranded annealed copper. Circular section, TypeA according to IEC 61158-</Text><Text id="20051" page="125">2. Temperature rating 90°C. Size: 1.5 mm² min for 4-wire serial communications.</Text><Text id="20052" page="125">Identification Pair1 - White/Blue stripe and Blue/White stripe Pair2 - White/Orange stripe and Orange/White stripe.</Text><Text id="20053" page="125">2. Insulation Mica impregnated glass tape beneath extruded layer of flame retardant cross linked Polyethylene (XLPE) or equivalent Ethylene Propylene Rubber (EPR) or equivalent Silicone Rubber (S95) or material as per data sheet.</Text><Text id="20056" page="125">3. Coll Foil Overall foil shield with one tinned copper drain wire.</Text><Text id="20057" page="125">4. Braid Tinned copper braid in continuous contact with the tinned copper drain wire.</Text><Text id="20058" page="125">5. Inner jacket Flame retardant Low Smoke Zero Halogen Compound. Colour: Black.</Text><Text id="20060" page="125">7. Outer jacket Flame Retardant Low Smoke Zero Halogen Compound.</Text><Text id="20061" page="125">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’ and Fire Resistant to IEC 60331.</Text><Text id="20062" page="126">(G1) Two core, Collective Screen, unarmoured, flame retardant (Control Cable). (XLPE/Coll Scr/LSHF) Voltage Rating: 300/500V</Text><Text id="20065" page="126">1. Conductors Standed annealed copper. Circular section, Class 2 according to IEC 60228. Temperature rating 90°C. Size: 2.5 mm 2 min for control signals, Digital Output &amp; Solenoid signals.</Text><Text id="20067" page="126">2. Insulation Flame retardant material as per data sheet.</Text><Text id="20070" page="126">3. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="20071" page="126">4. Cable screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="20072" page="126">5. Outer jacket Flame retardant Low Smoke Zero Halogen compound. Entire cable assembly shall be Flame retardant to IEC 60332.Pt.3.Cat`A’.</Text><Text id="20073" page="126">Note: This cable type shall be only utilized for indoor application where the cable is installed and fully routed within the same building.</Text><Text id="20074" page="126">(G2) Two core, armoured, flame retardant (Control Cable). (XLPE/SWA/ LSHF) Voltage Rating: 300/500V</Text><Text id="20077" page="127">1. Conductors Standed annealed copper. Circular section, Class 2 according to IEC 60228. Temperature rating 90°C. Size: 2.5 mm 2 min for control signals, Digital Output &amp; Solenoid signals.</Text><Text id="20079" page="127">2. Insulation Flame retardant material as per data sheet.</Text><Text id="20082" page="127">3. Fillers Flame retardant Low Smoke Zero Halogen Compound.</Text><Text id="20083" page="127">4. Inner jacket Flame retardant Low Smoke Zero Halogen Compound. Colour: Black.</Text><Text id="20085" page="127">6. Outer jacket Flame retardant Low Smoke Zero Halogen compound. Entire cable assembly shall be Flame retardant to IEC 60332.Pt.3.Cat`A’.</Text><Text id="20086" page="127">(G3) Multi-core, Collective Screen, unarmoured, flame retardant (Control Cable). (XLPE/Coll Scr/LSHF) Voltage Rating: 300/500V</Text><Text id="20089" page="128">1. Conductors Standed annealed copper. Circular section, Class 2 according to IEC 60228. Temperature rating 90°C. Size: 2.5 mm 2 min for control signals, Digital Output &amp; Solenoid signals.</Text><Text id="20090" page="128">Identification Red, Black, Brown, Blue for 4 cores. White with Black core numbers for 7, 12, 19, 25 and 37 cores. Each core printed with a number throughout the cable at equal (150mm) distances.</Text><Text id="20091" page="128">2. Insulation Flame retardant material as per data sheet.</Text><Text id="20094" page="128">3. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="20095" page="128">4. Cable screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="20096" page="128">5. Outer jacket Flame retardant Low Smoke Zero Halogen compound.</Text><Text id="20097" page="128">Entire cable assembly shall be Flame retardant to IEC 60332.Pt.3.Cat`A’.</Text><Text id="20098" page="128">Note: This cable type shall be only utilized for indoor application where the cable is installed and fully routed within the same building.</Text><Text id="20099" page="129">(G4) Multi - core, armoured, flame retardant (Control Cable). (XLPE/SWA/ LSHF) Voltage Rating: 300/500V</Text><Text id="20102" page="129">1. Conductors Standed annealed copper. Circular section, Class 2 according to IEC 60228. Temperature rating 90°C. Size: 2.5 mm 2 min for control signals, Digital Output &amp; Solenoid signals.</Text><Text id="20103" page="129">Identification Red, Black, Brown, Blue for 4 cores. White with Black core numbers for 7, 12, 19, 25 and 37 cores. Each core printed with a number throughout the cable at equal (150mm) distances.</Text><Text id="20104" page="129">2. Insulation Flame retardant material as per data sheet.</Text><Text id="20106" page="129">3. Fillers Cores laid up with extruded PVC filler for 5 cores. For 6 cores or more wrapping of polyester tape.</Text><Text id="20107" page="129">4. Inner jacket Flame retardant Low Smoke Zero Halogen Compound. Colour: Black.</Text><Text id="20109" page="129">6. Outer jacket Flame retardant Low Smoke Zero Halogen compound. Entire cable assembly shall be Flame retardant to IEC 60332.Pt.3.Cat`A’.</Text><Text id="20110" page="130">(G5) Multi-core, collective screen, armoured, external buried, flame retardant (Control Cable). (XLPE/Coll Scr/LS/SWA/LSHF) Voltage Rating: 300/500V</Text><Text id="20111" page="130">1 2 3 4 5 6 7 8 9</Text><Text id="20113" page="130">1. Conductors Stranded annealed copper. Circular section, Class 2 according to IEC 60228. Temperature rating 90°C. Size: 2.5 mm 2 min for control signals, Digital Output &amp; Solenoid signals.</Text><Text id="20114" page="130">Identification Red, Black, Brown, Blue for 4 cores. White with Black core numbers for 7, 12, 19, 25 and 37 cores. Each core printed with a number throughout the cable at equal (150mm) distances.</Text><Text id="20115" page="130">2. Insulation Flame retardant material as per data sheet.</Text><Text id="20118" page="130">3. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="20119" page="131">1. Conductors Standed annealed copper. Circular section, Class 2 according to IEC 60228. Temperature rating 90°C. Size: 2.5 mm 2 min for control signals, Digital Output &amp; Solenoid signals.</Text><Text id="20121" page="131">2. Insulation Flame retardant material as per data sheet.</Text><Text id="20123" page="131">3. Fillers Cores laid up with extruded PVC filler or Flame retardant Low Smoke Zero Halogen</Text><Text id="20125" page="131">4. Cable Screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="20126" page="131">5. Inner jacket Flame retardant Low Smoke Zero Halogen Compound. Colour: Black.</Text><Text id="20128" page="131">7. Outer jacket Flame retardant Low Smoke Zero Halogen compound. Entire cable assembly shall be Flame retardant to IEC 60332.Pt.3.Cat`A’.</Text><Text id="20129" page="131">(G7) Multi-core, Collective Screen, armoured, flame retardant (Control Cable). (XLPE/Coll Scr/SWA/ LSHF) Voltage Rating: 300/500V</Text><Text id="20132" page="132">1. Conductors Standed annealed copper. Circular section, Class 2 according to IEC 60228. Temperature rating 90°C. Size: 2.5 mm 2 min for control signals, Digital Output &amp; Solenoid signals.</Text><Text id="20133" page="132">Identification Red, Black, Brown, Blue for 4 cores. White with Black core numbers for 7, 12, 19, 25 and 37 cores. Each core printed with a number throughout the cable at equal (150mm) distances.</Text><Text id="20134" page="132">2. Insulation Flame retardant material as per data sheet.</Text><Text id="20135" page="132">CABLE: Cores are twisted together and covered with:</Text><Text id="20136" page="132">3. Fillers Cores laid up with extruded PVC filler or Flame retardant Low Smoke Zero Halogen</Text><Text id="20138" page="132">4. Cable Screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="20139" page="132">5. Inner jacket Flame retardant Low Smoke Zero Halogen Compound. Colour: Black.</Text><Text id="20141" page="132">7. Outer jacket Flame retardant Low Smoke Zero Halogen compound.</Text><Text id="20143" page="132">Entire cable assembly shall be Flame retardant to IEC 60332.Pt.3.Cat`A’.</Text><Text id="20144" page="133">(H1) Two core, Collective Screen, unarmoured, fire resistant (Control Cable). (XLPE/Coll Scr/LSHF) Voltage Rating: 300/500V</Text><Text id="20147" page="133">1. Conductors Standed annealed copper. Circular section, Class 2 according to IEC 60228. Temperature rating 90°C. Size: 2.5 mm 2 min for control signals, Digital Output &amp; Solenoid signals.</Text><Text id="20149" page="133">2. Insulation Mica impregnated glass tape beneath extruded layer of flame retardant cross</Text><Text id="20150" page="133">linked Polyethylene (XLPE) or equivalent Ethylene Propylene Rubber (EPR) or equivalent Silicone Rubber (S95) or material as per data sheet.</Text><Text id="20153" page="133">3. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="20154" page="133">4. Cable screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="20155" page="133">5. Outer jacket Flame Retardant Low Smoke Zero Halogen Compound.</Text><Text id="20156" page="133">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’ and Fire Resistant to IEC 60331.</Text><Text id="20157" page="133">Note: This cable type shall be only utilized for indoor application where the cable is installed and fully routed within the same building.</Text><Text id="20158" page="134">(H2) Two core, armoured, fire resistant (Control Cable). (Mica/XLPE/SWA/ LSHF) Voltage Rating: 300/500V</Text><Text id="20161" page="134">1. Conductors Standed annealed copper. Circular section, Class 2 according to IEC 60228. Temperature rating 90°C. Size: 2.5 mm 2 min for Fire and Gas (Sounder/Beacon), Digital Output &amp; Solenoid signals and ESD, F&amp;G and PA applications.</Text><Text id="20163" page="134">2. Insulation Mica impregnated glass tape beneath extruded layer of flame retardant cross</Text><Text id="20164" page="134">linked Polyethylene (XLPE) or equivalent Ethylene Propylene Rubber (EPR) or equivalent Silicone Rubber (S95) or material as per data sheet.</Text><Text id="20167" page="134">3. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="20168" page="134">4. Inner jacket Flame retardant Low Smoke Zero Halogen Compound or equivalent EPR or equivalent S95 Rubber, LSZH. Colour: Black.</Text><Text id="20170" page="134">6. Outer jacket Flame retardant Low Smoke Zero Halogen Compound.</Text><Text id="20171" page="134">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’ and Fire Resistant to IEC 60331.</Text><Text id="20172" page="135">(H3) Multi-core, Collective Screen, unarmoured, fire resistant (Control Cable). (XLPE/Coll Scr/LSHF) Voltage Rating: 300/500V</Text><Text id="20175" page="135">1. Conductors Standed annealed copper. Circular section, Class 2 according to IEC 60228. Temperature rating 90°C. Size: 2.5 mm 2 min for control signals, Digital Output &amp; Solenoid signals.</Text><Text id="20176" page="135">Identification Red, Black, Brown, Blue for 4 cores. White with Black core numbers for 7, 12, 19, 25 and 37 cores. Each core printed with a number throughout the cable at equal (150mm) distances.</Text><Text id="20177" page="135">2. Insulation Mica impregnated glass tape beneath extruded layer of flame retardant cross</Text><Text id="20178" page="135">linked Polyethylene (XLPE) or equivalent Ethylene Propylene Rubber (EPR) or equivalent Silicone Rubber (S95) or material as per data sheet.</Text><Text id="20181" page="135">3. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="20182" page="135">4. Cable screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="20183" page="135">5. Outer jacket Flame retardant Low Smoke Zero Halogen Compound.</Text><Text id="20184" page="135">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’ and Fire Resistant to IEC 60331.</Text><Text id="20185" page="135">Note: This cable type shall be only utilized for indoor application where the cable is installed and fully routed within the same building.</Text><Text id="20186" page="136">(H4) Multi-core, armoured, fire resistant (Control Cable). (Mica/XLPE/SWA/ LSHF) Voltage Rating: 300/500V</Text><Text id="20189" page="136">1. Conductors Standed annealed copper. Circular section, Class 2 according to IEC 60228. Temperature rating 90°C. Size: 2.5 mm 2 min for Fire and Gas (Sounder/Beacon), Digital Output &amp; Solenoid signals and ESD, F&amp;G and PA applications.</Text><Text id="20190" page="136">Identification Red, Black, Brown, Blue for 4 cores. White with Black core numbers for 7, 12, 19, 25 and 37 cores. Each core printed with a number throughout the cable at equal (150mm) distances.</Text><Text id="20191" page="136">2. Insulation Mica impregnated glass tape beneath extruded layer of flame retardant cross</Text><Text id="20192" page="136">linked Polyethylene (XLPE) or equivalent Ethylene Propylene Rubber (EPR) or equivalent Silicone Rubber (S95) or material as per data sheet.</Text><Text id="20195" page="136">3. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="20196" page="136">4. Inner jacket Flame retardant Low Smoke Zero Halogen Compound or equivalent EPR or equivalent S95 Rubber, LSZH. Colour: Black.</Text><Text id="20198" page="136">6. Outer jacket Flame retardant Low Smoke Zero Halogen Compound.</Text><Text id="20200" page="136">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’ and Fire Resistant to IEC 60331.</Text><Text id="20201" page="137">(H5) Multi-core, collective screen, armoured, external buried, fire resistant (Control Cable).</Text><Text id="20203" page="137">1 2 3 4 5 6 7 8 9</Text><Text id="20205" page="137">1. Conductors Stranded annealed copper. Circular section, Class 2 according to IEC 60228. Temperature rating 90°C. Size: 2.5 mm² min for control signals, Fire and Gas (Sounder/Beacon), Digital Output &amp; Solenoid signals and ESD, F&amp;G and PA applications.</Text><Text id="20206" page="137">Identification Red, Black, Brown, Blue for 4 cores. White with Black core numbers for 7, 12, 19, 25 and 37 cores. Each core printed with a number throughout the cable at equal (150mm) distances.</Text><Text id="20207" page="137">2. Insulation Mica impregnated glass tape beneath extruded layer of flame retardant cross linked Polyethylene (XLPE) or equivalent Ethylene Propylene Rubber (EPR) or equivalent Silicone Rubber (S95) or material as per data sheet.</Text><Text id="20210" page="137">3. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="20211" page="137">4. Cable screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="20212" page="137">5. Inner jacket Flame retardant Low Smoke Zero Halogen Compound or equivalent EPR or equivalent S95 Rubber, LSZH. Colour: Black.</Text><Text id="20213" page="137">6. Inner Sheath Lead Sheath (or Lead pipe). A multi-layered Inner Sheath (AL/HDPE/PA instead of lead sheath) will be considered if the multi-layer sheath provides the same protection as a lead sheath for hydrocarbons, chemical and solvents, saline water ingress and vermin protection, as per BS 50288-7 section 4.18.2.</Text><Text id="20214" page="137">7. Bedding Flame retardant Low Smoke Zero Halogen Compound ,LSZH.</Text><Text id="20217" page="137">9. Outer jacket Flame retardant Low Smoke Zero Halogen Compound</Text><Text id="20218" page="137">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’ and Fire Resistant to IEC 60331.</Text><Text id="20219" page="138">(H6) Two core, Collective Screen, armoured, fire resistant (Control Cable). (Mica/XLPE/Coll Scr/SWA/ LSHF) Voltage Rating: 300/500V</Text><Text id="20222" page="138">1. Conductors Standed annealed copper. Circular section, Class 2 according to IEC 60228. Temperature rating 90°C. Size: 2.5 mm 2 min for Fire and Gas (Sounder/Beacon), Digital Output &amp; Solenoid signals and ESD, F&amp;G and PA applications.</Text><Text id="20224" page="138">2. Insulation Mica impregnated glass tape beneath extruded layer of flame retardant cross</Text><Text id="20225" page="138">linked Polyethylene (XLPE) or equivalent Ethylene Propylene Rubber (EPR) or equivalent Silicone Rubber (S95) or material as per data sheet.</Text><Text id="20227" page="138">3. Fillers Flame retardant moisture resistant material , LSZH.</Text><Text id="20228" page="138">4. Cable shield One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire</Text><Text id="20229" page="138">5. Inner jacket Flame retardant Low Smoke Zero Halogen Compound or equivalent EPR or equivalent S95 Rubber, LSZH. Colour: Black.</Text><Text id="20231" page="138">7. Outer jacket Flame retardant Low Smoke Zero Halogen Compound.</Text><Text id="20232" page="138">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’ and Fire Resistant to IEC 60331. .</Text><Text id="20233" page="139">(H7) Multi-core, Collective Screen, armoured, fire resistant (Control Cable). (XLPE/Coll Scr/SWA/ LSHF) Voltage Rating: 300/500V</Text><Text id="20236" page="139">1. Conductors Standed annealed copper. Circular section, Class 2 according to IEC 60228. Temperature rating 90°C. Size: 2.5 mm 2 min for control signals, Digital Output &amp; Solenoid signals and ESD, F&amp;G and PA applications.</Text><Text id="20237" page="139">Identification Red, Black, Brown, Blue for 4 cores. White with Black core numbers for 7, 12, 19, 25 and 37 cores. Each core printed with a number throughout the cable at equal (150mm) distances.</Text><Text id="20238" page="139">2. Insulation Mica impregnated glass tape beneath extruded layer of flame retardant cross</Text><Text id="20239" page="139">linked Polyethylene (XLPE) or equivalent Ethylene Propylene Rubber (EPR) or equivalent Silicone Rubber (S95) or material as per data sheet.</Text><Text id="20240" page="139">CABLE: Cores are twisted together and covered with:</Text><Text id="20241" page="139">3. Fillers Flame retardant Low Smoke Zero Halogen Compound ,LSZH.</Text><Text id="20242" page="139">4. Cable Screen One tinned copper 0.50 mm² min solid drain wire and aluminium backed Mylar tape. Tape shall be helically wrapped with 25% overlap. Aluminium tape shall be in continuous contact with the drain wire.</Text><Text id="20243" page="139">5. Inner jacket Flame retardant Low Smoke Zero Halogen Compound ,LSZH. Colour: Black.</Text><Text id="20245" page="139">7. Outer jacket Flame retardant Low Smoke Zero Halogen compound. Entire cable assembly shall be Flame retardant to IEC 60332.Pt.3.Cat`A’.</Text><Text id="20246" page="140">(I1) Fibre Optic cable (24Fibres), flame retardant, indoor.</Text><Text id="20249" page="140">1. Fibres Single mode fibre or Multimode fibres, to suit the glass type needed for the application. Minimum 6 fibres per buffer tube.</Text><Text id="20250" page="140">Fibre Identification Colour Coded in accordance with EIA/TIA-598. Fibre colours shall not be repeated. 1 st group of 12 fibres are solid colours. 2 nd group of 12 fibres are solid colours with a stripe.</Text><Text id="20251" page="140">2. Buffer tubes Flame retardant PolyButylene Terephthalate (PBT) or Halar Fluoroplastic or equivalent extruded tube with a moisture resistant gel filling compound. Multiple buffer tubes are twisted around a GRP (or equivalent dielectric material) rod provided for central strength and a filler core, flame retardant LSZH.</Text><Text id="20252" page="140">Tube Identification Colour Coded in accordance with EIA/TIA-598. Tube colours shall not be repeated. Each tube shall be a solid colour and be marked with a number.</Text><Text id="20254" page="140">3. Separator Water blocking E-glass yarn and polyester tape, together with Aramid strength members and a Rip cord.</Text><Text id="20255" page="140">4. Armour Tape Aluminium or Polyester or Corrugated steel tape armour and a Rip cord.</Text><Text id="20256" page="140">5. Outer jacket Flame retardant Low Smoke Zero Halogen compound Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’.</Text><Text id="20257" page="140">Colour Coded in accordance with EIA/TIA-598 with a printed legend on the outer jacket of the cable at equal distances to identify the quantity and types of glass fibres within the cable.</Text><Text id="20258" page="141">(I2) Fibre Optic cable (24Fibres), flame retardant, outdoor.</Text><Text id="20261" page="141">1. Fibres Single mode fibre or Multimode fibres, to suit the glass type needed for the application. Minimum 6 fibres per buffer tube.</Text><Text id="20262" page="141">Fibre Identification Colour Coded in accordance with EIA/TIA-598. Fibre colours shall not be repeated. 1 st group of 12 fibres are solid colours. 2 nd group of 12 fibres are solid colours with a stripe.</Text><Text id="20263" page="141">2. Buffer tubes Flame retardant PolyButylene Terephthalate (PBT) or Halar Fluoroplastic or equivalent extruded tube with a moisture resistant gel filling compound. Multiple buffer tubes are twisted around a GRP (or equivalent dielectric material) rod provided for central strength and a filler core, flame retardant LSZH.</Text><Text id="20264" page="141">Tube Identification Colour Coded in accordance with EIA/TIA-598. Tube colours shall not be repeated. Each tube shall be a solid colour and be marked with a number.</Text><Text id="20266" page="141">3. Separator Water blocking E-glass yarn or Aramid yarn and polyester tape.</Text><Text id="20267" page="141">4. Armour Tape Aluminium or Polyester or Corrugated steel tape armour and a Rip cord.</Text><Text id="20268" page="141">5. Inner jacket Flame retardant Low Smoke Zero Halogen Compound) Together with Aramid strength members and a Rip cord. Colour: Black.</Text><Text id="20269" page="141">6. Outer jacket Flame retardant Low Smoke Zero Halogen compound.</Text><Text id="20270" page="142">(I3) Fibre Optic cable (24Fibres), flame retardant, outdoor, armoured.</Text><Text id="20273" page="142">1. Fibres Single mode fibre or Multimode fibres, to suit the glass type needed for the application. Minimum 6 fibres per buffer tube.</Text><Text id="20274" page="142">Fibre Identification Colour Coded in accordance with EIA/TIA-598. Fibre colours shall not be repeated. 1 st group of 12 fibres are solid colours. 2 nd group of 12 fibres are solid colours with a stripe.</Text><Text id="20275" page="142">2. Buffer tubes Flame retardant PolyButylene Terephthalate (PBT) or Halar Fluoroplastic or equivalent extruded tube with a moisture resistant gel filling compound. Multiple buffer tubes are twisted around a GRP (or equivalent dielectric material) rod provided for central strength and a filler core, flame retardant LSZH.</Text><Text id="20276" page="142">Tube Identification Colour Coded in accordance with EIA/TIA-598. Tube colours shall not be repeated. Each tube shall be a solid colour and be marked with a number.</Text><Text id="20278" page="142">3. Separator Water blocking E-glass yarn or Aramid yarn and polyester tape.</Text><Text id="20279" page="142">4. Armour Tape Aluminium or Polyester or Corrugated steel tape armour and a Rip cord.</Text><Text id="20280" page="142">5. Inner jacket Flame retardant Low Smoke Zero Halogen Compound , LSZH Colour: Black.</Text><Text id="20281" page="142">6. Armour Galvanised Steel Wire Armour or equivalent steel tape armour and a Rip cord.</Text><Text id="20282" page="142">7. Outer jacket Flame retardant Low Smoke Zero Halogen compound Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’.</Text><Text id="20283" page="143">(I4) Fibre Optic cable (2 up to 24Fibres), flame retardant, indoor or outdoor, armoured.</Text><Text id="20286" page="143">1. Fibres Single mode fibre or Multimode fibres, to suit the glass type needed for the application. Maximum of 24 individual fibres. Temperature rating 70°C.</Text><Text id="20287" page="143">Fibre Identification Colour Coded in accordance with EIA/TIA-598. Fibre colours shall not be repeated. 1 st group of 12 fibres are solid colours. 2 nd group of 12 fibres are solid colours with a stripe.</Text><Text id="20288" page="143">2. Uni-Tube Flame retardant PolyButylene Terephthalate (PBT) or Halar Fluoroplastic or equivalent extruded loose tube with a moisture resistant gel filling compound. Flame retardant LSZH.</Text><Text id="20290" page="143">3. Separator Water blocking E-glass yarn or Aramid yarn and polyester tape.</Text><Text id="20291" page="143">4. Armour Tape Aluminium or Corrugated steel tape armour and a Rip cord.</Text><Text id="20292" page="143">5. Outer jacket Flame retardant Low Smoke Zero Halogen compound</Text><Text id="20293" page="143">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’.</Text><Text id="20294" page="143">Colour Coded in accordance with EIA/TIA-598 with a printed legend on the outer jacket of the cable at equal distances to identify the quantity and types of glass fibres within the cable.</Text><Text id="20295" page="144">(I5) Fibre Optic cable (2 up to 24Fibres), armoured, external buried, flame retardant.</Text><Text id="20296" page="144">1 2 3 4 5 6 7 8 9</Text><Text id="20298" page="144">1. Fibres Single mode fibre or Multimode fibres, to suit the glass type needed for the application. Minimum 6 fibres per buffer tube.</Text><Text id="20299" page="144">Fibre Identification Colour Coded in accordance with EIA/TIA-598. Fibre colours shall not be repeated. 1 st group of 12 fibres are solid colours. 2 nd group of 12 fibres are solid colours with a stripe.</Text><Text id="20300" page="144">2. Buffer tubes Flame retardant PolyButylene Terephthalate (PBT) or Halar Fluoroplastic or equivalent extruded tube with a moisture resistant gel filling compound. Multiple buffer tubes are twisted around a GRP (or equivalent dielectric material) rod provided for central strength and a filler core, flame retardant LSZH.</Text><Text id="20301" page="144">Tube Identification Colour Coded in accordance with EIA/TIA-598. Tube colours shall not be repeated. Each tube shall be a solid colour and be marked with a number.</Text><Text id="20303" page="144">3. Separator Water blocking E-glass yarn or Aramid yarn and polyester tape.</Text><Text id="20304" page="144">4. Armour Tape Aluminium or Polyester or Corrugated steel tape armour and a Rip cord.</Text><Text id="20305" page="144">5. Inner jacket Flame retardant Low Smoke Zero Halogen Compound , LSZH Colour: Black.</Text><Text id="20306" page="144">6. Inner Sheath Lead Sheath (or Lead pipe). A multi-layered Inner Sheath (AL/HDPE/PA instead of lead sheath) will be considered if the multi-layer sheath provides the same protection as a lead sheath for hydrocarbons, chemical and solvents, saline water ingress and vermin protection, as per BS 50288-7 section 4.18.2.</Text><Text id="20308" page="144">7. Bedding Flame retardant Low Smoke Zero Halogen Compound.</Text><Text id="20310" page="144">8. Armour Galvanised Steel Wire Armour or equivalent steel tape armour and a Rip cord.</Text><Text id="20311" page="144">9. Outer jacket Flame retardant Low Smoke Zero Halogen compound</Text><Text id="20312" page="145">(J1) Fibre Optic cable (24Fibres), fire resistant, indoor.</Text><Text id="20315" page="145">1. Fibres Single mode fibre or Multimode fibres, to suit the glass type needed for the application. Minimum 6 fibres per buffer tube.</Text><Text id="20316" page="145">Fibre Identification Colour Coded in accordance with EIA/TIA-598. Fibre colours shall not be repeated. 1 st group of 12 fibres are solid colours. 2 nd group of 12 fibres are solid colours with a stripe.</Text><Text id="20317" page="145">2. Buffer tubes Flame retardant PolyButylene Terephthalate (PBT) or Halar Fluoroplastic or equivalent extruded tube with a moisture resistant gel filling compound. Multiple buffer tubes are twisted around a GRP (or equivalent dielectric material) rod provided for central strength and a filler core, flame retardant LSZH.</Text><Text id="20318" page="145">Tube Identification Colour Coded in accordance with EIA/TIA-598. Tube colours shall not be repeated. Each tube shall be a solid colour and be marked with a number.</Text><Text id="20320" page="145">3. Separator Water blocking E-glass yarn and polyester tape, together with Aramid strength members and a Rip cord.</Text><Text id="20321" page="145">4. Armour Tape Aluminium or Polyester or Corrugated steel tape armour and a Rip cord.</Text><Text id="20322" page="145">5. Outer jacket Flame retardant Low Smoke Zero Halogen Compound.</Text><Text id="20323" page="145">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’.</Text><Text id="20324" page="145">Colour Coded in accordance with EIA/TIA-598 with a printed legend on the outer jacket of the cable at equal distances to identify the quantity and types of glass fibres within the cable.</Text><Text id="20325" page="146">(J2) Fibre Optic cable (24Fibres), fire resistant, outdoor.</Text><Text id="20328" page="146">1. Fibres Single mode fibre or Multimode fibres, to suit the glass type needed for the application. Minimum 6 fibres per buffer tube.</Text><Text id="20329" page="146">Fibre Identification Colour Coded in accordance with EIA/TIA-598. Fibre colours shall not be repeated. 1 st group of 12 fibres are solid colours. 2 nd group of 12 fibres are solid colours with a stripe.</Text><Text id="20330" page="146">2. Buffer tubes Flame retardant PolyButylene Terephthalate (PBT) or Halar Fluoroplastic or equivalent extruded tube with a moisture resistant gel filling compound. Multiple buffer tubes are twisted around a GRP (or equivalent dielectric material) rod provided for central strength and a filler core, flame retardant LSZH.</Text><Text id="20331" page="146">Tube Identification Colour Coded in accordance with EIA/TIA-598. Tube colours shall not be repeated. Each tube shall be a solid colour and be marked with a number.</Text><Text id="20333" page="146">3. Separator Water blocking E-glass yarn or Aramid yarn and polyester tape.</Text><Text id="20334" page="146">4. Armour Tape Aluminium or Polyester or Corrugated steel tape armour and a Rip cord.</Text><Text id="20335" page="146">5. Inner jacket Flame retardant Low Smoke Zero Halogen Compound) Together with Aramid strength members and a Rip cord. Colour: Black.</Text><Text id="20336" page="146">6. Outer jacket Flame retardant Low Smoke Zero Halogen Compound.</Text><Text id="20337" page="146">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’ and Fire resistant to IEC 60331 . Colour Coded in accordance with EIA/TIA-598 with a printed legend on the outer jacket of the cable at equal distances to identify the quantity and types of glass fibres within the cable.</Text><Text id="20338" page="147">(J3) Fibre Optic cable (24Fibres), fire resistant, outdoor, armoured.</Text><Text id="20341" page="147">1. Fibres Single mode fibre or Multimode fibres, to suit the glass type needed for the application. Minimum 6 fibres per buffer tube.</Text><Text id="20342" page="147">Fibre Identification Colour Coded in accordance with EIA/TIA-598. Fibre colours shall not be repeated. 1 st group of 12 fibres are solid colours. 2 nd group of 12 fibres are solid colours with a stripe.</Text><Text id="20343" page="147">2. Buffer tubes Flame retardant PolyButylene Terephthalate (PBT) or Halar Fluoroplastic or equivalent extruded tube with a moisture resistant gel filling compound. Multiple buffer tubes are twisted around a GRP (or equivalent dielectric material) rod provided for central strength and a filler core, flame retardant LSZH.</Text><Text id="20344" page="147">Tube Identification Colour Coded in accordance with EIA/TIA-598. Tube colours shall not be repeated. Each tube shall be a solid colour and be marked with a number.</Text><Text id="20346" page="147">3. Separator Water blocking E-glass yarn or Aramid yarn and polyester tape.</Text><Text id="20347" page="147">4. Armour Tape Aluminium or Polyester or Corrugated steel tape armour and a Rip cord.</Text><Text id="20348" page="147">5. Inner jacket Flame retardant Low Smoke Zero Halogen Compound or equivalent EPR or equivalent S95 Rubber, LSZH to IEC 60332. Pt.3. Cat`A’. Fire resistant to IEC 60331. Together with Aramid strength members and a Rip cord. Colour: Black.</Text><Text id="20349" page="147">6. Armour Galvanised Steel Wire Armour or equivalent steel tape armour and a Rip cord.</Text><Text id="20350" page="147">7. Outer jacket Flame retardant Low Smoke Zero Halogen Compound.</Text><Text id="20351" page="147">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’ and Fire resistant to IEC 60331.</Text><Text id="20352" page="148">(J4) Fibre Optic cable (2 up to 24Fibres), fire resistant, indoor or outdoor, armoured.</Text><Text id="20355" page="148">1. Fibres Single mode fibre or Multimode fibres, to suit the glass type needed for the application. Maximum of 24 individual fibres. Temperature rating 70°C.</Text><Text id="20356" page="148">Fibre Identification Colour Coded in accordance with EIA/TIA-598. Fibre colours shall not be repeated. 1 st group of 12 fibres are solid colours. 2 nd group of 12 fibres are solid colours with a stripe.</Text><Text id="20357" page="148">2. Uni-Tube Flame retardant PolyButylene Terephthalate (PBT) or Halar Fluoroplastic or equivalent extruded loose tube with a moisture resistant gel filling compound. Flame retardant LSZH.</Text><Text id="20359" page="148">3. Separator Water blocking E-glass yarn or Aramid yarn and polyester tape.</Text><Text id="20360" page="148">4. Armour Tape Aluminium or Corrugated steel tape armour and a Rip cord.</Text><Text id="20361" page="148">5. Outer jacket Flame retardant Low Smoke Zero Halogen Compound.</Text><Text id="20362" page="148">Entire cable assembly shall be Flame Retardant to IEC 60332. Pt.3. Cat`A’ and Fire resistant to IEC 60331.</Text><Text id="20363" page="148">Colour Coded in accordance with EIA/TIA-598 with a printed legend on the outer jacket of the cable at equal distances to identify the quantity and types of glass fibres within the cable.</Text><Text id="20366" page="24">Thermocouple cables shall have overall sheath colour in accordance with lEC 60584-3 as follows: Outer sheath colour for Building Fire Alarm Panel’s cables shall be as per purchase cable data sheets.</Text><Text id="20367" page="50">For example LSZH/MGT XLPE/IS &amp; OS/LZSH/GSWA/LZSH/5P/1.5 mm²/Type K</Text><Text id="20369" page="2">Group Projects &amp; Engineering / PT&amp;CS CUSTODIAN Specification applicable to ADNOC &amp; ADNOC Group Companies ADNOC</Text><Text id="20370" page="7">Abbreviations AL/HDPE/PA Aluminium / High Density Polyethylene / Polyamide (Nylon) CSA Cross Sectional Area EPR Ethylene Propylene Rubber ESD Emergency Shutdown System FAT Factory Acceptance Test FF Foundation Fieldbus FGS Fire and Gas System FO Fibre Optic GSWA Galvanised Steel Wire Armour GSWB Galvanised Steel Wire Braid HOFR Heat, Oil and Flame Retardant I/O Inputs/Outputs I.S. Intrinsically Safe LSZH Low Smoke Zero Halogen MGT/EPR Mica Glass Tape Ethylene Propylene Rubber MGT/XLPE Mica Glass Tape Cross Linked Polyethylene PA Public Address System PTFE Poly Tetra Fluoro Ethylene S95 Silicone Rubber XLPE Cross Linked Polyethylene</Text><Text id="20371" page="8">Technical Definitions Term Definition Armour Metallic wire mesh covering for protection against mechanical damage during cable installation and operation. Bedding Non-metallic layer applied between Armour and Lead Sheath to maintain electric isolation between metallic layers. Buried Cables that are required to go underground or laid underground. Conductor Metal used to transfer electrical energy from point to point. Drain wire Un-insulated wire laid in contact with an electrical screen or an electrical shield which has the specific function of earthing an electrostatic charge by ensuring a low resistive path throughout the length of the cable Fibre Optics A technology that transmits information as light pulses along a glass or plastic fibre. Fillers Non-conducting components cabled with the insulated conductors or optical fibres to impart roundness, flexibility, tensile strength or a combination of all three to the cable. Fire Resistance Ability of an electric cable to continue to operate in a designated manner whilst subjected to a specified flame source for a specified period under specified conditions. Flame Resistance The ability of a material not to fuel a flame once the source of heat is removed. Inner Sheath Non-metallic cover generally applied under a metallic sheath or armour. Insulation Non-conducting electrical isolation material between conductors Laying Up The cores of cables are laid up with suitable filling elements to form a compact circular assembly. Suitable binder tape(s) may be applied. Outer Sheath Non-metallic cover applied over armour ensuring the protection of the cable from the outside atmosphere. Quad A four conductor cable. Screen/Shield Earthed metallic layer surrounding a cable which confines the electric field generated by the cable within the cable cores, pair(s), triples(s) or quad(s),</Text><Text id="20372" page="9">and/or protects the core(s), pair(s), triple(s) or quad(s) from external influence. Stranded conductor Conductor consisting of a number of individual wires all which generally have a helical form.</Text><Text id="20373" page="10">The International Electrotechnical Commission (IEC) IEC 60079 Explosive Atmospheres. All parts. IEC 60092 Electrical installations in ships, covers power and instrumentation cables to be used on ships and in mobile marine environments. IEC 60092-350 General construction and test methods of power, control and instrumentation cables for shipboard and offshore applications. Electrical installations in ships: Choice and installation of electrical cables. IEC 60092 -352 IEC 60092-360 Electrical, mechanical and particular characteristics of insulation and sheathing materials for shipboard and offshore units, power, control, instrumentation and telecommunications cables. IEC 60092-376 Screened and unscreened cables for control and instrumentation circuits on ships and fixed/mobile offshore units. These cables have extruded solid insulation with a voltage rating of 150/250V. IEC 60228 Conductors of Insulated cables. IEC 60304 Standard colours for insulation for low-frequency cables and wires. IEC 60331 Tests for Electric Cables under Fire Conditions - Circuit integrity. All series, all parts. IEC 60332 Tests on electric and optical fibre cables under fire conditions. All series, all parts. IEC 60529 Degrees of protection provided by enclosures (IP Code). IEC 60584 Thermocouples. All parts. IEC 60684-2 Flexible Insulating Sleeving Method of Test</Text><Text id="20374" page="11">IEC 60754 Tests on Gases Evolved during Combustion of Materials from Cables. All parts. IEC 61784 Industrial communication networks – Fieldbus Profiles. All parts. IEC 60793 Optical fibres: Measurement methods and test procedures. All parts. IEC 60794 Optical fibre cables: Generic specification. All parts. IEC 60811 Electrical and Optical Fibre Cables - Test Methods for Non-metallic material. All parts. IEC 61034 Measurement of smoke density of cables burning under defined conditions. All parts. IEC 61158-SER Digital data communications for measurement and control - Fieldbus for use in industrial control systems – All parts. IEC 61158-1 Industrial Communication Networks - Fieldbus specifications - Part 1: Overview and guidance for the IEC 61158 and IEC 61784 series. IEC 61158-2 Industrial Communication Networks - Fieldbus specifications - Part2: Physical Layer Specification and Service Definition. FF-844 H1 Foundation Fieldbus Type A H1 Cable Test Specification IEC 61280 Fibre optic communication subsystem basic test procedures. All parts. Fibre optic communication subsystems. Generic specification. IEC 61281-1 IEC TR 61282 Fibre optic communication system design guide. Calibration of fibre optic power meters. IEC 61315 Attenuation uniformity in optical fibres. IEC 62033 Optical fibres - Measurement methods - Microbending sensitivity. IEC TR 62221 IEC TR 62222 Fire performance of communication cables installed in buildings. IEC TR 63194 Guidance on colour coding of optical fibre cables. British Standards Institution (BSI) BS 6004 Electric cables. PVC insulated and PVC sheathed cables for voltages up to and including 300/500 V, for electric power and lighting.</Text><Text id="20375" page="12">BS 6387 Test method for resistance to fire of cables required to maintain circuit integrity under fire conditions. BS 6701 Telecommunication equipment and cabling. BS 6883 Elastomer insulated cables for fixed wiring in ships and on mobile and fixed offshore units. Requirements and test methods. BS 7655 Specification for insulating and sheathing materials for cables. All parts. BS 7917 Elastomer insulated fire resistant (limited circuit integrity) cables for fixed wiring in ships and on mobile and fixed offshore units. Requirements and test methods. European Standards (EN) EN 10204 Metallic products. Types of inspection documents. EN 10218 Steel wire and wire products. General. All parts. EN 10244-2 Steel wire and wire products. Non-ferrous metallic coatings on steel wire. Zinc or zinc alloy coatings. EN 10257-1 Zinc or zinc alloy coated non-alloy steel wire for armouring either power cables or telecommunication cables. Land cables. EN 12548 Lead and alloys. Lead alloy ingots for electric cable sheathing and for sleeves. EN 50173 Information Technology – Generic Cabling Systems. EN 50200 Method of test for resistance to fire of unprotected small cables for use in Emergency Circuits. EN 50288 Multi-element metallic cables used in analogue and digital communication and control. EN 50288-1 Part1: Generic specification. EN 50288-7 Part7: Sectional specification for instrumentation and control cables. EN 50289 Communication cables. Specifications for test methods. Electrical test methods. General requirements, all series and all parts. EN 50290 Communication cables. Common design rules and construction. All parts. EN 50290-4 Communication cables. General considerations for the use of cables - Guide to use. EN 50307 Lead and lead alloys. Lead and lead alloy sheaths and sleeves of electric cables. American Society for Testing and Materials (ASTM) International</Text><Text id="20376" page="13">ASTM B3-13 Standard Specification for Soft or Annealed Copper Wire. ASTM B33-10 Standard Specification for Tin-Coated Soft or Annealed Copper Wire for Electrical Purposes. ASTM D2863-19 Standard Test Method for Measuring the Minimum Oxygen Concentration to Support Candle-Like Combustion of Plastics (Oxygen Index). Underwriters Laboratories (UL) UL1581 Reference Standard for Electrical Wires, Cables, and Flexible Cords. The Institute of Electrical and Electronics Engineers, Inc. (IEEE) IEEE-802 Standard for local and metropolitan area networks: Overview and architecture -IEEE Computer Society Document. Engineering Equipment Materials Users Association (EEMUA) EEMUA 133 Specification for underground armoured cable protected against solvent penetration and corrosive attack. Electronic Industries Association (EIA) EIA TIA-455 Standard Test Procedure for Fibre Optic Fibres, Cables, Transducers, Sensors, Connecting and Terminating Devices, and Other Fibre Optic Components. EIA TIA-492 AAA-A Detail Specification for 62.5-Micrometer Core Diameter/125-Micrometer Cladding Diameter Class Ia Graded-Index Multimode Optical Fibres. EIA TIA-492AAA Detail Specification for Class IVa Dispersion -Unshifted Single-Mode Optical Fibres. EIA TIA-598 Optical Fibre Colour Coding International Telecommunications Union (ITU) ITU-T G650 Definition and test methods for the relevant parameters of single mode fibres – Series G. ITU-T G651 Characteristics of a 50/125 micrometer multimode graded index optical fibre cable – Series G. ITU-T G-652 Characteristics of a Single-Mode Optical Fibre Cable Series G: Transmission Systems and Media, Digital Systems and Networks Transmission Media Characteristics - Optical Fibre Cables. International Organization for Standardization (ISO)</Text><Text id="20377" page="14">ISO 4589-2 Plastics. Determination of burning behaviour by oxygen index. Ambienttemperature test. ISO 9001 Quality Management Systems - Requirements. ISO 9004 Managing for the Sustained Success of an Organization – A Quality Management Approach ISO 19011 Guidelines for Auditing Management Systems</Text><Text id="20378" page="16">Sr.No. Description 1 Instrumentation Cables used for ESD and FGS applications and HSE Critical services shall be Fire Resistance in accordance with IEC 60331. 2 Instrumentation cables used for intrinsic safe applications shall be individually and overall shielded as per IEC 60079-14 Clause 16.2.2.8.</Text><Text id="20379" page="19">Conductor Size (Note 1) Analogue 4-20 mA, Frequency, Foundation Fieldbus 1, 2, 10 &amp; 20 Pair 1 Pair - 1.5 mm2 2, 10 &amp; 20 Pair – 1 mm2 Digital Inputs- 24 VDC Potential Free contact, Proximity Namur, MCC/Switchgear contacts (Note 2) Thermocouple inputs RTD inputs, 3 Wire Transducers, F &amp; G Detectors 1, 2, 10 &amp; 20 Triad 1, 2 &amp; 10 Quad 1 Triad/Quad - 1.5 mm2 2, 10 &amp; 20 Triad/Quad- 1 mm2 or 1.5 mm2 based on voltage drop requirements 1, 2, 10 &amp; 20 Pair 2.5 mm2 Digital Outputs to field devices 24 VDC for Solenoid Valves, Sounder, Beacon etc. Serial Communication RS485/232/422 1, 2 Pair 1.5 mm2</Text><Text id="20380" page="20">Cable Type Reference (A1, B5, C6) Applications Cable Type Flame Retardant Fire Resistant Single Pair Cables 1 Pair 2 Wire Signals-Analogue, Digital, Pulse, Voltage A1- Unarmoured A5 – Armoured A10- Armoured Buried B1- Unarmoured B5 – Armoured B10- Armoured Buried Multi Pair Cables 2, 10 &amp; 20 Pair 2 Wire Signals-Analogue, Digital, Pulse, Voltage A2 – Unarmoured A6, A7 – Armoured A11- Armoured Buried B2 – Unarmoured B6, B7 – Armoured B11- Armoured Buried 3 Wire Signals- RTD, FGS Single Triad Cables 1 Triad A3 – Unarmoured A8 – Armoured A12- Armoured Buried B3 – Unarmoured B8 – Armoured B12- Armoured Buried 3 Wire Signals- RTD, FGS Multi Triad Cables 2, 10, 20 Triad A4 – Unarmoured A9 – Armoured A13 – Armoured Buried B4 – Unarmoured B9, B14 – Armoured B13, B15 – Armoured Buried Thermocouple Signals Single Pair T/C Cable 1 Pair C1, C2, C3 – Unarmoured C4, C5, C6 - Armoured D1, D2, D3 – Unarmoured D4, D5, D6 - Armoured Thermocouple Signals Multi Pair T/C Cable 2, 10, 20 Pair C7, C8, C9 – Armoured C10, C11, C12 Armoured Buried D7, D8, D9 – Armoured D10, D11, D12 Armoured Buried Foundation Fieldbus, RS 485 Single Pair Cables 1 Pair E1 – Unarmoured E3 – Armoured E5 – Armoured Buried F1 – Unarmoured F3 – Armoured F5 – Armoured Buried Foundation Fieldbus, RS 485 Multi Pair Cables 2, 10 &amp; 20 Pair E2 – Unarmoured E4 – Armoured E6 – Armoured Buried F2 – Unarmoured F4 – Armoured F6 – Armoured Buried</Text><Text id="20381" page="21">Applications Cable Type Flame Retardant Fire Resistant Communication Cables 4 Wire Multi Pair Cable 2 Pair E7 – Unarmoured E8 - Armoured E7 – Unarmoured E8 - Armoured Single Pair Cables 1 Pair Digital Outputs 24VDC – Solenoid, Beacons, Hooter A1- Unarmoured A5 – Armoured A10- Armoured Buried B1- Unarmoured B5 – Armoured B10- Armoured Buried Multi Pair Cables 2, 10 &amp; 20 Pair Digital Outputs 24VDC – Solenoid, Beacons, Hooter A2 – Unarmoured A7 – Armoured A11- Armoured Buried B2 – Unarmoured B7 – Armoured B11- Armoured Buried I1 J1 Fibre Optic cables Unarmoured 24 fibre, multi-loose tube, single jacket I2, I3, I4,I5 J2, J3, J4 Fibre Optic cables Armoured 24 fibre, multi-loose tube, double jacket 24 fibre, multi-loose tube, armoured</Text><Text id="20382" page="22">Description Colour Thermocouple Type - B (+) Grey, (-) White Thermocouple Type – E (+) Violet, (-) White Thermocouple Type – J (+) Black, (-) White Thermocouple Type – K (+) Green, (-) White Thermocouple Type – N (+) Pink, (-) White Thermocouple Type – R or Type - S (+) Orange, (-) White Thermocouple Type - T (+) Brown, (-) White</Text><Text id="20383" page="22">Type of Cables Core 1 Core 2 Core 3 Core 4 - Pair Black White - -Quad Triad Black White Red Blue Black White Red</Text><Text id="20384" page="24">Description Outer Sheath Colour Thermocouple Type - B Blue Thermocouple Type – E Violet Thermocouple Type – J Black Thermocouple Type – K Green Thermocouple Type – R or Type - S Orange Thermocouple Type - T Brown</Text><Text id="20385" page="24">Description Outer Sheath Colour Intrinsically safe cables for Instrument and Control Blue Non-intrinsically safe cables for Instrument and Control Black Non-intrinsically safe cables for FGS. Red Intrinsically safe cables for FGS. Red with longitudinal blue strip Non-intrinsically safe Foundation Fieldbus cables Orange Intrinsically safe Foundation Fieldbus cables Orange with longitudinal blue strip</Text><Text id="20386" page="29">Sr.No. Description Single Mode Fibre Multimode step Index/Multimode Graded Index 1 Core Glass Diameter 6.25/125 or 50/125 micrometer 9 / 125 micrometer 2 Maximum Attenuation 3.0 dB/Km@850 nm 0.8 dB/Km@1300 nm 0.4 dB/Km@1310 nm 0.25 dB/Km@1550 nm 3 Minimum Bandwidth 20 GHz 400 MHz/Km@850 nm 600 MHz/Km@1300 nm G.652.D IEC 60793-210 Type A1b (62.5 micrometer) 4 Optical Characteristics G.651.1 (50 micrometer) G.655 NZ-DSF (DWDM System) 5 Minimum Fibre Count 24 6 Fibre Identification Colour Coded Fibre Tubes 7 Fibre Tube Extruded Tubes, Jelly filled with longitudinal tightness 8 6 Minimum Core in a tube 9 Inner Jacket Black Flame Retardant Polyvinyl Chloride 10 Fibre Sheath Non-leaded Hydrocarbon Resistant, Moisture Barrier with Metallic Tape 11 Bedding Polyvinyl Chloride, Black Colour 12 Armour Galvanized Steel Wire Armour or Equivalent strength Steel Tape Armour 13 Rip Cord Yes 14 Outer Jacket Black Flame Retardant Polyvinyl Chloride, Black Colour</Text><Text id="20387" page="50">LSZH 1 2 3 4 5 6 7 Type</Text><Text id="20388" page="52">LSZH 1 2 3 4 5 6 7 Colour</Text><Text id="20389" page="53">LSZH 1 2 3 4 5 6 7 8 9 Colour</Text><Text id="20390" page="54">LSZH 1 2 3 4 5 6 7 Colour</Text></Spec>